Ultrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow /

In order to process and simulate a tomography system, it has been found that Visual C++ programming has an advantage one step ahead compared to Visual Basic programming. Besides having an ability of higher processing speed, Visual C++ is also encapsulates an extended function rather than Visual Basi...

Full description

Bibliographic Details
Main Authors: Ruzairi Abdul Rahim 1967- 632663, Universiti Teknologi Malaysia. Fakulti Kejuruteraan Elektrik 8633
Format: text
Language:eng
Published: Johor Bahru, Johor : PENERBIT UTM PRESS, 2008
Subjects:
_version_ 1826449507641982976
author Ruzairi Abdul Rahim 1967- 632663
Universiti Teknologi Malaysia. Fakulti Kejuruteraan Elektrik 8633
author_facet Ruzairi Abdul Rahim 1967- 632663
Universiti Teknologi Malaysia. Fakulti Kejuruteraan Elektrik 8633
author_sort Ruzairi Abdul Rahim 1967- 632663
collection OCEAN
description In order to process and simulate a tomography system, it has been found that Visual C++ programming has an advantage one step ahead compared to Visual Basic programming. Besides having an ability of higher processing speed, Visual C++ is also encapsulates an extended function rather than Visual Basic. Real-time simulation of ultrasonic tomography system applied to liquid and gas flow has been done by previous researcher using Visual Basic 6.0 software programming. The program is excellent but unfortunately, the processing speed is not fast enough. Therefore, Visual C++ is expected to perform a higher processing speed, better than Visual Basic. The main purpose of this research is to construct and develop a tomogram for visualizing the liquid and gas flow using Visual C++ software in process tomography system. By using a suitable image reconstruction algorithm, the tomogram will be interfaced with the tomography measurement system and the computer using Keithley DAS-1802HC interfacing card. By using Visual C++ programming software, the results showed an improvement in the image reconstruction speed and therefore, a high-speed measurement of ultrasonic tomography system could achieved.
first_indexed 2024-03-05T11:41:29Z
format text
id KOHA-OAI-TEST:463876
institution Universiti Teknologi Malaysia - OCEAN
language eng
last_indexed 2024-09-23T23:35:02Z
publishDate 2008
publisher Johor Bahru, Johor : PENERBIT UTM PRESS,
record_format dspace
spelling KOHA-OAI-TEST:4638762024-09-23T00:44:30ZUltrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow / Ruzairi Abdul Rahim 1967- 632663 Universiti Teknologi Malaysia. Fakulti Kejuruteraan Elektrik 8633 text Book chapter 481883 Johor Bahru, Johor : PENERBIT UTM PRESS,2008©2008engIn order to process and simulate a tomography system, it has been found that Visual C++ programming has an advantage one step ahead compared to Visual Basic programming. Besides having an ability of higher processing speed, Visual C++ is also encapsulates an extended function rather than Visual Basic. Real-time simulation of ultrasonic tomography system applied to liquid and gas flow has been done by previous researcher using Visual Basic 6.0 software programming. The program is excellent but unfortunately, the processing speed is not fast enough. Therefore, Visual C++ is expected to perform a higher processing speed, better than Visual Basic. The main purpose of this research is to construct and develop a tomogram for visualizing the liquid and gas flow using Visual C++ software in process tomography system. By using a suitable image reconstruction algorithm, the tomogram will be interfaced with the tomography measurement system and the computer using Keithley DAS-1802HC interfacing card. By using Visual C++ programming software, the results showed an improvement in the image reconstruction speed and therefore, a high-speed measurement of ultrasonic tomography system could achieved.Includes bibliographical references and index.In order to process and simulate a tomography system, it has been found that Visual C++ programming has an advantage one step ahead compared to Visual Basic programming. Besides having an ability of higher processing speed, Visual C++ is also encapsulates an extended function rather than Visual Basic. Real-time simulation of ultrasonic tomography system applied to liquid and gas flow has been done by previous researcher using Visual Basic 6.0 software programming. The program is excellent but unfortunately, the processing speed is not fast enough. Therefore, Visual C++ is expected to perform a higher processing speed, better than Visual Basic. The main purpose of this research is to construct and develop a tomogram for visualizing the liquid and gas flow using Visual C++ software in process tomography system. By using a suitable image reconstruction algorithm, the tomogram will be interfaced with the tomography measurement system and the computer using Keithley DAS-1802HC interfacing card. By using Visual C++ programming software, the results showed an improvement in the image reconstruction speed and therefore, a high-speed measurement of ultrasonic tomography system could achieved.PSZ_JBTomographyImage processingMicrosoft Visual C++URN:ISBN:9789673541126
spellingShingle Tomography
Image processing
Microsoft Visual C++
Ruzairi Abdul Rahim 1967- 632663
Universiti Teknologi Malaysia. Fakulti Kejuruteraan Elektrik 8633
Ultrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow /
title Ultrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow /
title_full Ultrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow /
title_fullStr Ultrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow /
title_full_unstemmed Ultrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow /
title_short Ultrasonic Tomography System Using Visual C++ Applied to Liquid / Gas Flow /
title_sort ultrasonic tomography system using visual c applied to liquid gas flow
topic Tomography
Image processing
Microsoft Visual C++
work_keys_str_mv AT ruzairiabdulrahim1967632663 ultrasonictomographysystemusingvisualcappliedtoliquidgasflow
AT universititeknologimalaysiafakultikejuruteraanelektrik8633 ultrasonictomographysystemusingvisualcappliedtoliquidgasflow