Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) :
Part 1: Gives requirements for thermal insulation batts made from man-made mineral fibre and intended for filling cavities in cavity wall having masonry and/or concrete leaves. Covers definitions, composition, dimensional deviations, density, resistance to water retention, resistance to wicking, res...
Main Author: | |
---|---|
Format: | |
Published: |
London : British Standards Institution,
1986
|
Subjects: |
_version_ | 1796654644418576384 |
---|---|
author | British Standards Institution, author 8096 |
author_facet | British Standards Institution, author 8096 |
author_sort | British Standards Institution, author 8096 |
collection | OCEAN |
description | Part 1: Gives requirements for thermal insulation batts made from man-made mineral fibre and intended for filling cavities in cavity wall having masonry and/or concrete leaves. Covers definitions, composition, dimensional deviations, density, resistance to water retention, resistance to wicking, resistances to water penetration, pH value and water-soluble salt content, resistance to settlement, non-combustibility, thermal conductivity and marking. -- Part 2: Recommendations for filling cavities in cavity walls with masonry and/or concrete leaves up to 12m in height (normal three storey construction). Criteria for design and construction of walls to be insulated. Essential precautions and procedures for the installation. Appendix gives additional recommendations for buildings exceeding 12m in height. |
first_indexed | 2024-03-04T14:53:31Z |
format | |
id | KOHA-OAI-TEST:48319 |
institution | Universiti Teknologi Malaysia - OCEAN |
last_indexed | 2024-03-04T14:53:31Z |
publishDate | 1986 |
publisher | London : British Standards Institution, |
record_format | dspace |
spelling | KOHA-OAI-TEST:483192021-09-07T03:13:23ZThermal insulation of cavity walls using man-made mineral fibre batts (slabs) : British Standards Institution, author 8096 London : British Standards Institution,1986©1986Part 1: Gives requirements for thermal insulation batts made from man-made mineral fibre and intended for filling cavities in cavity wall having masonry and/or concrete leaves. Covers definitions, composition, dimensional deviations, density, resistance to water retention, resistance to wicking, resistances to water penetration, pH value and water-soluble salt content, resistance to settlement, non-combustibility, thermal conductivity and marking. -- Part 2: Recommendations for filling cavities in cavity walls with masonry and/or concrete leaves up to 12m in height (normal three storey construction). Criteria for design and construction of walls to be insulated. Essential precautions and procedures for the installation. Appendix gives additional recommendations for buildings exceeding 12m in height.Includes references.Part 1. Specification: 1 Scope 2 Definitions 3 Composition 4 Dimensional deviations 5 Density 6 Resistance to water retention 7 Resistance to wicking 8 Resistance to water penetration 9 pH value and water-soluble salt content 10 Resistance to settlement 11 Non-combustibility 12 Thermal conductivity 13 Marking -- Appendices: A Measurement of recovered thickness B Method of test for resistance to water retention C Method of test for resistance to wicking D Method of test for resistance to water penetration E Method of test for determination of pH value and water-soluble chloride and sulphate contents F Method of test for resistance to settlement G Method of test for thermal resistance -- Tables: 1 Permissible dimensional deviations 2 Commonly available sizes -- Figures: 1 Measurement of recovered thickness 2 Measurement of resistance to settlement.Part 2. Code of practice: 1 Scope 2 Definitions 3 Design of cavity walls intended for insulation with batts 4 Materials and storage 5 Installation -- Appendix: A Installation of man-made mineral fibre batts in building exceeding 12 m in height -- Table: 1 Tolerances for cavity widths -- Figures: 1 Typical section through top of wall at verge 2 Batts terminating below the top of a wall 3 Installation of batts in low parapets 4 Placing the first row of batts 5 Building procedure 6 Fitting batts around building components 7 Typical corner details 8 Use of off-cuts 9 Protection of batts from mortar droppings.Part 1: Gives requirements for thermal insulation batts made from man-made mineral fibre and intended for filling cavities in cavity wall having masonry and/or concrete leaves. Covers definitions, composition, dimensional deviations, density, resistance to water retention, resistance to wicking, resistances to water penetration, pH value and water-soluble salt content, resistance to settlement, non-combustibility, thermal conductivity and marking. -- Part 2: Recommendations for filling cavities in cavity walls with masonry and/or concrete leaves up to 12m in height (normal three storey construction). Criteria for design and construction of walls to be insulated. Essential precautions and procedures for the installation. Appendix gives additional recommendations for buildings exceeding 12m in height.PSZ_JBStandards, EngineeringStandards, EngineeringURN:ISBN:0580147886URN:ISBN:0580147967 |
spellingShingle | Standards, Engineering Standards, Engineering British Standards Institution, author 8096 Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) : |
title | Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) : |
title_full | Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) : |
title_fullStr | Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) : |
title_full_unstemmed | Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) : |
title_short | Thermal insulation of cavity walls using man-made mineral fibre batts (slabs) : |
title_sort | thermal insulation of cavity walls using man made mineral fibre batts slabs |
topic | Standards, Engineering Standards, Engineering |
work_keys_str_mv | AT britishstandardsinstitutionauthor8096 thermalinsulationofcavitywallsusingmanmademineralfibrebattsslabs |