Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime

Lightweight foamed concrete is a unique product of construction material that has been used in the construction of the building. The usage of lightweight foamed concrete as the bricks was nof widely used in Malaysia. Cost savings in using mortar for bricklaying can be reduced because mortar just pas...

Full description

Bibliographic Details
Main Author: Nur Afirah, Kamalrulzaman
Format: Undergraduates Project Papers
Language:English
Published: 2014
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/11255/1/NUR%20AFIRAH%20BINTI%20KAMALRULZAMAN.pdf
_version_ 1796990950260604928
author Nur Afirah, Kamalrulzaman
author_facet Nur Afirah, Kamalrulzaman
author_sort Nur Afirah, Kamalrulzaman
collection UMP
description Lightweight foamed concrete is a unique product of construction material that has been used in the construction of the building. The usage of lightweight foamed concrete as the bricks was nof widely used in Malaysia. Cost savings in using mortar for bricklaying can be reduced because mortar just pasted to the face of the hollow brick alone compared with solid brick that need to paste mortar around the face. Hollow concrete brick are slow to absorb heat and with the using of this brick is suitable for a living due to the nature of concrete that is not hot plus empty space in the brick and heat will flow to avoid the heat trapped inside it. The purpose of this study is to determine the effect of different size of the hollow to compressive strength of foamed concrete bricks and also to determine the compressive strength of hollow foamed concrete bricks under different curing regimes. In this study, the density of the lightweight foamed concrete used is 1600 kg/M3 while the size of the brick used is 215 x 102.5 x 65 mm. Sample A represent the solid brick while Sample B, Sample C and Sample D were the bricks with hollow size 55 x 55 mm, 60 x 60 mm and 65 x 65 mm respectively. Eighty samples of bricks with different hollow sizes have prepared. Under the bed position, the compressive strength was 30 - 56% decreased with the increasing size of hollow while for stretcher was 52 - 76%. The compressive strength in both stretcher and bed position under water-curing regime was 1 - 20% higher compared to samples under air-curing regime.
first_indexed 2024-03-06T11:59:06Z
format Undergraduates Project Papers
id UMPir11255
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T11:59:06Z
publishDate 2014
record_format dspace
spelling UMPir112552023-11-07T04:44:06Z http://umpir.ump.edu.my/id/eprint/11255/ Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime Nur Afirah, Kamalrulzaman TA Engineering (General). Civil engineering (General) Lightweight foamed concrete is a unique product of construction material that has been used in the construction of the building. The usage of lightweight foamed concrete as the bricks was nof widely used in Malaysia. Cost savings in using mortar for bricklaying can be reduced because mortar just pasted to the face of the hollow brick alone compared with solid brick that need to paste mortar around the face. Hollow concrete brick are slow to absorb heat and with the using of this brick is suitable for a living due to the nature of concrete that is not hot plus empty space in the brick and heat will flow to avoid the heat trapped inside it. The purpose of this study is to determine the effect of different size of the hollow to compressive strength of foamed concrete bricks and also to determine the compressive strength of hollow foamed concrete bricks under different curing regimes. In this study, the density of the lightweight foamed concrete used is 1600 kg/M3 while the size of the brick used is 215 x 102.5 x 65 mm. Sample A represent the solid brick while Sample B, Sample C and Sample D were the bricks with hollow size 55 x 55 mm, 60 x 60 mm and 65 x 65 mm respectively. Eighty samples of bricks with different hollow sizes have prepared. Under the bed position, the compressive strength was 30 - 56% decreased with the increasing size of hollow while for stretcher was 52 - 76%. The compressive strength in both stretcher and bed position under water-curing regime was 1 - 20% higher compared to samples under air-curing regime. 2014-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/11255/1/NUR%20AFIRAH%20BINTI%20KAMALRULZAMAN.pdf Nur Afirah, Kamalrulzaman (2014) Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang.
spellingShingle TA Engineering (General). Civil engineering (General)
Nur Afirah, Kamalrulzaman
Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime
title Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime
title_full Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime
title_fullStr Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime
title_full_unstemmed Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime
title_short Compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime
title_sort compressive strength of lightweight foamed concrete bricks with different size of hollow under different curing regime
topic TA Engineering (General). Civil engineering (General)
url http://umpir.ump.edu.my/id/eprint/11255/1/NUR%20AFIRAH%20BINTI%20KAMALRULZAMAN.pdf
work_keys_str_mv AT nurafirahkamalrulzaman compressivestrengthoflightweightfoamedconcretebrickswithdifferentsizeofhollowunderdifferentcuringregime