PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems
In this research, the automatic generation control (AGC) of three parallel-connected power plants is utilized to tune the proportional-integral-derivative (PID) controller using Multistart algorithm (MS). The AGC loop is used to minimize the frequency deviation and control the power exchange in ord...
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
Universiti Malaysia Pahang
2016
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/15794/1/P075%20pg544-551.pdf |
_version_ | 1825823403117903872 |
---|---|
author | Mushtaq, Najeeb Ramdan, Razali K. G., Mohammed Hamdan, Daniyal Ali, M. Humada |
author_facet | Mushtaq, Najeeb Ramdan, Razali K. G., Mohammed Hamdan, Daniyal Ali, M. Humada |
author_sort | Mushtaq, Najeeb |
collection | UMP |
description | In this research, the automatic generation control (AGC) of three parallel-connected power plants is utilized to tune
the proportional-integral-derivative (PID) controller using Multistart algorithm (MS). The AGC loop is used to minimize the frequency deviation and control the power exchange in order to maintain them at their scheduled values due to the changes of the step-load disturbance. The optimal parameters of the PID scheme optimized by the proposed MS algorithm are compared with that one’s obtained by GA algorithm, and the proposed method has proven that its performance is more efficient and improved as well. Integral Square Error (ISE) is considered as an objective function for both algorithms to determine its performance index value for the same parallel-connected power system. From combination sets MS_PID_ISE and GA_PID_ISE; the settling time, maximum deviation and peak time are analyzed and compared in the time domain. Based on the simulated results, MS_ISE has better settling time, lesser peak time, and lower maximum deviation as compared with GA_ISE. Both of MS and GA algorithms are coded using MATLAB software. |
first_indexed | 2024-03-06T12:10:45Z |
format | Conference or Workshop Item |
id | UMPir15794 |
institution | Universiti Malaysia Pahang |
language | English |
last_indexed | 2024-03-06T12:10:45Z |
publishDate | 2016 |
publisher | Universiti Malaysia Pahang |
record_format | dspace |
spelling | UMPir157942018-02-05T03:22:08Z http://umpir.ump.edu.my/id/eprint/15794/ PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems Mushtaq, Najeeb Ramdan, Razali K. G., Mohammed Hamdan, Daniyal Ali, M. Humada TK Electrical engineering. Electronics Nuclear engineering In this research, the automatic generation control (AGC) of three parallel-connected power plants is utilized to tune the proportional-integral-derivative (PID) controller using Multistart algorithm (MS). The AGC loop is used to minimize the frequency deviation and control the power exchange in order to maintain them at their scheduled values due to the changes of the step-load disturbance. The optimal parameters of the PID scheme optimized by the proposed MS algorithm are compared with that one’s obtained by GA algorithm, and the proposed method has proven that its performance is more efficient and improved as well. Integral Square Error (ISE) is considered as an objective function for both algorithms to determine its performance index value for the same parallel-connected power system. From combination sets MS_PID_ISE and GA_PID_ISE; the settling time, maximum deviation and peak time are analyzed and compared in the time domain. Based on the simulated results, MS_ISE has better settling time, lesser peak time, and lower maximum deviation as compared with GA_ISE. Both of MS and GA algorithms are coded using MATLAB software. Universiti Malaysia Pahang 2016 Conference or Workshop Item PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/15794/1/P075%20pg544-551.pdf Mushtaq, Najeeb and Ramdan, Razali and K. G., Mohammed and Hamdan, Daniyal and Ali, M. Humada (2016) PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems. In: Proceedings of The National Conference for Postgraduate Research (NCON-PGR 2016) , 24-25 September 2016 , Universiti Malaysia Pahang (UMP), Pekan, Pahang. pp. 544-551.. (Published) http://ee.ump.edu.my/ncon/wp-content/uploads/2016/10/Proceeding-NCON-PGR-2016.zip |
spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Mushtaq, Najeeb Ramdan, Razali K. G., Mohammed Hamdan, Daniyal Ali, M. Humada PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems |
title | PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems
|
title_full | PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems
|
title_fullStr | PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems
|
title_full_unstemmed | PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems
|
title_short | PID Parameters Improvement for AGC in Three Parallel-Connected Power Systems
|
title_sort | pid parameters improvement for agc in three parallel connected power systems |
topic | TK Electrical engineering. Electronics Nuclear engineering |
url | http://umpir.ump.edu.my/id/eprint/15794/1/P075%20pg544-551.pdf |
work_keys_str_mv | AT mushtaqnajeeb pidparametersimprovementforagcinthreeparallelconnectedpowersystems AT ramdanrazali pidparametersimprovementforagcinthreeparallelconnectedpowersystems AT kgmohammed pidparametersimprovementforagcinthreeparallelconnectedpowersystems AT hamdandaniyal pidparametersimprovementforagcinthreeparallelconnectedpowersystems AT alimhumada pidparametersimprovementforagcinthreeparallelconnectedpowersystems |