A study of pipe leak source location using single channel acoustic emissions (AE) technique

This project was carried out as a study of pipe leak source location using single channel acoustic emissions (AE) technique. The objectives of this project are to study a reliable and affordable system capable of monitoring pipe leak and also to locate the source of the pipe leak using AE technique....

Full description

Bibliographic Details
Main Author: Mohd Firzikri, Abd Sata
Format: Undergraduates Project Papers
Language:English
Published: 2009
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/17063/1/35.A%20study%20of%20pipe%20leak%20source%20location%20using%20single%20channel%20acoustic%20emissions%20%28AE%29%20technique.pdf
_version_ 1796992019807076352
author Mohd Firzikri, Abd Sata
author_facet Mohd Firzikri, Abd Sata
author_sort Mohd Firzikri, Abd Sata
collection UMP
description This project was carried out as a study of pipe leak source location using single channel acoustic emissions (AE) technique. The objectives of this project are to study a reliable and affordable system capable of monitoring pipe leak and also to locate the source of the pipe leak using AE technique. A test rig consists of the pipe without leak and the pipe with leak was developed using circumferential of a galvanized steel pipe to run the experiments. The fluid used was water throughout the experiments. The flow of the water was controlled by a ball valve. The source of the AE signals was from the leak and it was captured using AE sensor with the help of Acoustic Emission Detector 2.1.3 software. For all pipe conditions, the values of hits, counts and RMS (average, maximum and minimum) were recorded and analyzed. All the values recorded were compared between the pipe without leak and the pipe with leak (full open valve and full close valve). The results were gained from 8 marked points each for all pipe conditions. The results showed that there was no AE activities on the pipe without leak while for the pipe with leak, the AE activities are greater for full close valve than full open valve. In addition, two equations for locating the source of the pipe leak were introduced from the RMS against distance graft. For the pipe with leak and full open valve, the equation is y = 0.011 x + 0.249. For the pipe with leak and full close valve, the equation is y = 0.017 x + 0.199.
first_indexed 2024-03-06T12:13:54Z
format Undergraduates Project Papers
id UMPir17063
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:13:54Z
publishDate 2009
record_format dspace
spelling UMPir170632023-03-09T04:05:06Z http://umpir.ump.edu.my/id/eprint/17063/ A study of pipe leak source location using single channel acoustic emissions (AE) technique Mohd Firzikri, Abd Sata TJ Mechanical engineering and machinery This project was carried out as a study of pipe leak source location using single channel acoustic emissions (AE) technique. The objectives of this project are to study a reliable and affordable system capable of monitoring pipe leak and also to locate the source of the pipe leak using AE technique. A test rig consists of the pipe without leak and the pipe with leak was developed using circumferential of a galvanized steel pipe to run the experiments. The fluid used was water throughout the experiments. The flow of the water was controlled by a ball valve. The source of the AE signals was from the leak and it was captured using AE sensor with the help of Acoustic Emission Detector 2.1.3 software. For all pipe conditions, the values of hits, counts and RMS (average, maximum and minimum) were recorded and analyzed. All the values recorded were compared between the pipe without leak and the pipe with leak (full open valve and full close valve). The results were gained from 8 marked points each for all pipe conditions. The results showed that there was no AE activities on the pipe without leak while for the pipe with leak, the AE activities are greater for full close valve than full open valve. In addition, two equations for locating the source of the pipe leak were introduced from the RMS against distance graft. For the pipe with leak and full open valve, the equation is y = 0.011 x + 0.249. For the pipe with leak and full close valve, the equation is y = 0.017 x + 0.199. 2009-11 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/17063/1/35.A%20study%20of%20pipe%20leak%20source%20location%20using%20single%20channel%20acoustic%20emissions%20%28AE%29%20technique.pdf Mohd Firzikri, Abd Sata (2009) A study of pipe leak source location using single channel acoustic emissions (AE) technique. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
spellingShingle TJ Mechanical engineering and machinery
Mohd Firzikri, Abd Sata
A study of pipe leak source location using single channel acoustic emissions (AE) technique
title A study of pipe leak source location using single channel acoustic emissions (AE) technique
title_full A study of pipe leak source location using single channel acoustic emissions (AE) technique
title_fullStr A study of pipe leak source location using single channel acoustic emissions (AE) technique
title_full_unstemmed A study of pipe leak source location using single channel acoustic emissions (AE) technique
title_short A study of pipe leak source location using single channel acoustic emissions (AE) technique
title_sort study of pipe leak source location using single channel acoustic emissions ae technique
topic TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/17063/1/35.A%20study%20of%20pipe%20leak%20source%20location%20using%20single%20channel%20acoustic%20emissions%20%28AE%29%20technique.pdf
work_keys_str_mv AT mohdfirzikriabdsata astudyofpipeleaksourcelocationusingsinglechannelacousticemissionsaetechnique
AT mohdfirzikriabdsata studyofpipeleaksourcelocationusingsinglechannelacousticemissionsaetechnique