Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury

This project is about the development of a walking gait cue stick for walking gait rehabilitation purposes. In this product development, a mechatronic device with stabiliser is attached to the walking gait cue stick. A line laser marker is accompanied with a stabilizer system to stabilized the proj...

Full description

Bibliographic Details
Main Authors: Idris, Mat Sahat, Mohd Nazrull, Syann Lesan, Mohd Azrul Hisham, Mohd Adib
Format: Conference or Workshop Item
Language:English
Published: Penerbit Universiti Teknologi Malaysia 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/19551/1/fkm-2017-idris-Development%20of%20walking%20gait%20cue%20stick.pdf
_version_ 1825811816535556096
author Idris, Mat Sahat
Mohd Nazrull, Syann Lesan
Mohd Azrul Hisham, Mohd Adib
author_facet Idris, Mat Sahat
Mohd Nazrull, Syann Lesan
Mohd Azrul Hisham, Mohd Adib
author_sort Idris, Mat Sahat
collection UMP
description This project is about the development of a walking gait cue stick for walking gait rehabilitation purposes. In this product development, a mechatronic device with stabiliser is attached to the walking gait cue stick. A line laser marker is accompanied with a stabilizer system to stabilized the projection of the laser. Two parameters that going to be stabilize which are the yaw and roll angle of the laser marking. The result shows good stability control for yaw angle up to 4.4 cm distance variation at the angle of 0 to 90 ̊ but relatively low stability control for the roll angle from 0 to 55 ̊ with distance variation up to 8.8 cm of the projected line laser mark. This result can further enhance walking gait training using cue stick with the aid of angles stabilising system.
first_indexed 2024-03-06T12:19:56Z
format Conference or Workshop Item
id UMPir19551
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:19:56Z
publishDate 2017
publisher Penerbit Universiti Teknologi Malaysia
record_format dspace
spelling UMPir195512018-05-15T06:20:35Z http://umpir.ump.edu.my/id/eprint/19551/ Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury Idris, Mat Sahat Mohd Nazrull, Syann Lesan Mohd Azrul Hisham, Mohd Adib TJ Mechanical engineering and machinery This project is about the development of a walking gait cue stick for walking gait rehabilitation purposes. In this product development, a mechatronic device with stabiliser is attached to the walking gait cue stick. A line laser marker is accompanied with a stabilizer system to stabilized the projection of the laser. Two parameters that going to be stabilize which are the yaw and roll angle of the laser marking. The result shows good stability control for yaw angle up to 4.4 cm distance variation at the angle of 0 to 90 ̊ but relatively low stability control for the roll angle from 0 to 55 ̊ with distance variation up to 8.8 cm of the projected line laser mark. This result can further enhance walking gait training using cue stick with the aid of angles stabilising system. Penerbit Universiti Teknologi Malaysia 2017 Conference or Workshop Item PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/19551/1/fkm-2017-idris-Development%20of%20walking%20gait%20cue%20stick.pdf Idris, Mat Sahat and Mohd Nazrull, Syann Lesan and Mohd Azrul Hisham, Mohd Adib (2017) Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury. In: iMEDITEC 2017 Proceeding International Medical Device and Technology Conference , 6-7 September 2017 , Johor Bahru, Malaysia. pp. 244-246.. ISBN 978-967-0194-93-6 (Published) http://www.utm.my/imeditec2017/files/2017/10/P65_Development-of-Walking-Gait-Cue-Stick-with-Laser-and-Stability-Control-for-Patients-with-Traumatic-Brain-Injury.pdf
spellingShingle TJ Mechanical engineering and machinery
Idris, Mat Sahat
Mohd Nazrull, Syann Lesan
Mohd Azrul Hisham, Mohd Adib
Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury
title Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury
title_full Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury
title_fullStr Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury
title_full_unstemmed Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury
title_short Development of Walking Gait Cue Stick with Laser and Stability Control for Patients with Traumatic Brain Injury
title_sort development of walking gait cue stick with laser and stability control for patients with traumatic brain injury
topic TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/19551/1/fkm-2017-idris-Development%20of%20walking%20gait%20cue%20stick.pdf
work_keys_str_mv AT idrismatsahat developmentofwalkinggaitcuestickwithlaserandstabilitycontrolforpatientswithtraumaticbraininjury
AT mohdnazrullsyannlesan developmentofwalkinggaitcuestickwithlaserandstabilitycontrolforpatientswithtraumaticbraininjury
AT mohdazrulhishammohdadib developmentofwalkinggaitcuestickwithlaserandstabilitycontrolforpatientswithtraumaticbraininjury