Effect of column size on the seismic capacity of elevated reinforced concrete water tank

One of the major natural calamities is earthquake which have the potential to cause damage to lives and lifeline facilities. Malaysia have experienced many earthquakes from surrounding regions and several local earthquakes. Therefore, it has become a necessary to evaluate the safety of buildings in...

Full description

Bibliographic Details
Main Author: Afiqah Azeera, Awang Damit
Format: Undergraduates Project Papers
Language:English
Published: 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/21245/1/Effect%20of%20column%20size%20on%20the%20seismic%20capacity%20of%20elevated%20reinforced%20concrete%20water%20tank.pdf
_version_ 1825812092797583360
author Afiqah Azeera, Awang Damit
author_facet Afiqah Azeera, Awang Damit
author_sort Afiqah Azeera, Awang Damit
collection UMP
description One of the major natural calamities is earthquake which have the potential to cause damage to lives and lifeline facilities. Malaysia have experienced many earthquakes from surrounding regions and several local earthquakes. Therefore, it has become a necessary to evaluate the safety of buildings in Malaysia when subjected to seismic action. Elevated reinforced concrete water tanks are one of the most essential structure to major cities and also in rural areas before, during and after a disaster such earthquake. It is important to prevent elevated reinforced concrete water tank from collapse so the water supply can be maintained. One of the methods used to evaluate the seismic capacity of elevated reinforced concrete water tank is the pushover analysis. Pushover analysis is based on the assumption that structure oscillate predominantly in the first mode or in the lower modes of vibration during a seismic event. The objective of this project is to study the effect of column size on the seismic capacity of elevated reinforced concrete water tank. A total number of 10 models of elevated reinforced concrete water tanks consist of 4 storeys and 7 storeys has been used for this project. All models have been designed repeatedly to 5 different size of column, where the beam size is fixed for each model. All models have been designed based on BS8110 to represent the existing elevated reinforced concrete water tanks. Then the pushover analysis has been conducted on all models to study the seismic capacity of elevated reinforced concrete water tank. An adequate information on seismic demands imposed on the structural system and its components by the designed ground motion are provided from the pushover analysis. Based on the pushover analysis conducted in this study, the elevated RC water tank with larger size of column tend to have higher value of force at yield state and ultimate state.
first_indexed 2024-03-06T12:24:01Z
format Undergraduates Project Papers
id UMPir21245
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:24:01Z
publishDate 2017
record_format dspace
spelling UMPir212452023-09-18T01:39:35Z http://umpir.ump.edu.my/id/eprint/21245/ Effect of column size on the seismic capacity of elevated reinforced concrete water tank Afiqah Azeera, Awang Damit TA Engineering (General). Civil engineering (General) One of the major natural calamities is earthquake which have the potential to cause damage to lives and lifeline facilities. Malaysia have experienced many earthquakes from surrounding regions and several local earthquakes. Therefore, it has become a necessary to evaluate the safety of buildings in Malaysia when subjected to seismic action. Elevated reinforced concrete water tanks are one of the most essential structure to major cities and also in rural areas before, during and after a disaster such earthquake. It is important to prevent elevated reinforced concrete water tank from collapse so the water supply can be maintained. One of the methods used to evaluate the seismic capacity of elevated reinforced concrete water tank is the pushover analysis. Pushover analysis is based on the assumption that structure oscillate predominantly in the first mode or in the lower modes of vibration during a seismic event. The objective of this project is to study the effect of column size on the seismic capacity of elevated reinforced concrete water tank. A total number of 10 models of elevated reinforced concrete water tanks consist of 4 storeys and 7 storeys has been used for this project. All models have been designed repeatedly to 5 different size of column, where the beam size is fixed for each model. All models have been designed based on BS8110 to represent the existing elevated reinforced concrete water tanks. Then the pushover analysis has been conducted on all models to study the seismic capacity of elevated reinforced concrete water tank. An adequate information on seismic demands imposed on the structural system and its components by the designed ground motion are provided from the pushover analysis. Based on the pushover analysis conducted in this study, the elevated RC water tank with larger size of column tend to have higher value of force at yield state and ultimate state. 2017-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/21245/1/Effect%20of%20column%20size%20on%20the%20seismic%20capacity%20of%20elevated%20reinforced%20concrete%20water%20tank.pdf Afiqah Azeera, Awang Damit (2017) Effect of column size on the seismic capacity of elevated reinforced concrete water tank. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang.
spellingShingle TA Engineering (General). Civil engineering (General)
Afiqah Azeera, Awang Damit
Effect of column size on the seismic capacity of elevated reinforced concrete water tank
title Effect of column size on the seismic capacity of elevated reinforced concrete water tank
title_full Effect of column size on the seismic capacity of elevated reinforced concrete water tank
title_fullStr Effect of column size on the seismic capacity of elevated reinforced concrete water tank
title_full_unstemmed Effect of column size on the seismic capacity of elevated reinforced concrete water tank
title_short Effect of column size on the seismic capacity of elevated reinforced concrete water tank
title_sort effect of column size on the seismic capacity of elevated reinforced concrete water tank
topic TA Engineering (General). Civil engineering (General)
url http://umpir.ump.edu.my/id/eprint/21245/1/Effect%20of%20column%20size%20on%20the%20seismic%20capacity%20of%20elevated%20reinforced%20concrete%20water%20tank.pdf
work_keys_str_mv AT afiqahazeeraawangdamit effectofcolumnsizeontheseismiccapacityofelevatedreinforcedconcretewatertank