Determination of electrical conductivity and pH from the different type honey suction pump

In this thesis presents the electrical conductivity and pH values of stingless bee honey samples collected from two different suction circulation; diaphragm vacuum pump and peristaltic pump was investigated. The honey samples were collected from the area of Bukit Goh, Kuantan, Pahang. Physicochemica...

Full description

Bibliographic Details
Main Author: Siti Nur Atikah, Mohd Noor
Format: Undergraduates Project Papers
Language:English
Published: 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/28988/1/Determination%20of%20electrical%20conductivity%20and%20ph%20from%20the%20different%20type%20honey%20suction%20pump.pdf
_version_ 1796994173667115008
author Siti Nur Atikah, Mohd Noor
author_facet Siti Nur Atikah, Mohd Noor
author_sort Siti Nur Atikah, Mohd Noor
collection UMP
description In this thesis presents the electrical conductivity and pH values of stingless bee honey samples collected from two different suction circulation; diaphragm vacuum pump and peristaltic pump was investigated. The honey samples were collected from the area of Bukit Goh, Kuantan, Pahang. Physicochemical analyses of parameters such as electrical conductivity and pH values have an important part in defining the overall properties of the honey and acquiring the quality of stingless bee honey in both type of pump. The data from the electrical conductivity shows that the honey samples from the diaphragm vacuum pump and peristaltic pump are 0.48 – 0.95 mS/cm and 0.25- 0.80 mS/cm respectively. Meanwhile, the data from the pH shows that the honey samples from the diaphragm vacuum pump and peristaltic pump are in range of 3.32 – 3.53 and 3.39 – 3.5 respectively. From the research, the value of electrical conductivity of honey sample from diaphragm vacuum pump is slightly higher than peristaltic pump but the pH values of the both pump are same in values. In conclusion, the peristaltic pump can maintain the physicochemical characteristics of stingless bee honey eventhough the both pumps have different in many ways.
first_indexed 2024-03-06T12:44:11Z
format Undergraduates Project Papers
id UMPir28988
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:44:11Z
publishDate 2019
record_format dspace
spelling UMPir289882023-07-11T02:03:30Z http://umpir.ump.edu.my/id/eprint/28988/ Determination of electrical conductivity and pH from the different type honey suction pump Siti Nur Atikah, Mohd Noor TK Electrical engineering. Electronics Nuclear engineering In this thesis presents the electrical conductivity and pH values of stingless bee honey samples collected from two different suction circulation; diaphragm vacuum pump and peristaltic pump was investigated. The honey samples were collected from the area of Bukit Goh, Kuantan, Pahang. Physicochemical analyses of parameters such as electrical conductivity and pH values have an important part in defining the overall properties of the honey and acquiring the quality of stingless bee honey in both type of pump. The data from the electrical conductivity shows that the honey samples from the diaphragm vacuum pump and peristaltic pump are 0.48 – 0.95 mS/cm and 0.25- 0.80 mS/cm respectively. Meanwhile, the data from the pH shows that the honey samples from the diaphragm vacuum pump and peristaltic pump are in range of 3.32 – 3.53 and 3.39 – 3.5 respectively. From the research, the value of electrical conductivity of honey sample from diaphragm vacuum pump is slightly higher than peristaltic pump but the pH values of the both pump are same in values. In conclusion, the peristaltic pump can maintain the physicochemical characteristics of stingless bee honey eventhough the both pumps have different in many ways. 2019-01 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/28988/1/Determination%20of%20electrical%20conductivity%20and%20ph%20from%20the%20different%20type%20honey%20suction%20pump.pdf Siti Nur Atikah, Mohd Noor (2019) Determination of electrical conductivity and pH from the different type honey suction pump. Faculty of Engineering Technology, Universiti Malaysia Pahang.
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Siti Nur Atikah, Mohd Noor
Determination of electrical conductivity and pH from the different type honey suction pump
title Determination of electrical conductivity and pH from the different type honey suction pump
title_full Determination of electrical conductivity and pH from the different type honey suction pump
title_fullStr Determination of electrical conductivity and pH from the different type honey suction pump
title_full_unstemmed Determination of electrical conductivity and pH from the different type honey suction pump
title_short Determination of electrical conductivity and pH from the different type honey suction pump
title_sort determination of electrical conductivity and ph from the different type honey suction pump
topic TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/28988/1/Determination%20of%20electrical%20conductivity%20and%20ph%20from%20the%20different%20type%20honey%20suction%20pump.pdf
work_keys_str_mv AT sitinuratikahmohdnoor determinationofelectricalconductivityandphfromthedifferenttypehoneysuctionpump