Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India
This case study presents the performance of a megawatt-scale grid-connected rooftop solar photovoltaic (PV) plant installed on the building rooftops of an educational institute (GITAM Deemed to be University) located in coastal regions (longitude 83° 23' 6.54'' E and latitude 17° 48...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/30085/1/Operational%20performance%20of%20megawatt-scale%20grid%20integrated%20rooftop.pdf |
_version_ | 1796994363430010880 |
---|---|
author | Thotakura, Sandhya Kondamudi, Sri Chandan Xavier, J. Francis Quanjin, Ma Reddy, Guduru Ramakrishna Gangwar, Pavan Davuluri, Sri Lakshmi |
author_facet | Thotakura, Sandhya Kondamudi, Sri Chandan Xavier, J. Francis Quanjin, Ma Reddy, Guduru Ramakrishna Gangwar, Pavan Davuluri, Sri Lakshmi |
author_sort | Thotakura, Sandhya |
collection | UMP |
description | This case study presents the performance of a megawatt-scale grid-connected rooftop solar photovoltaic (PV) plant installed on the building rooftops of an educational institute (GITAM Deemed to be University) located in coastal regions (longitude 83° 23' 6.54'' E and latitude 17° 48' 8.208'' N) of Andhra Pradesh. A framework is proposed to validate the existing simulation models that are used for PV project modeling. The validation is done by comparing the simulated performance with the real-time monitored performance. The studied PV plant consists of 3078 solar panels and 23 inverters. For the analysis, we recorded the PV plant operational data for 12 months from 1st October 2018 to 30th September 2019. Based on the monitored data and by following the proposed framework, performance analysis is carried out. The results include the estimated parameters like energy outputs, yield factor, capacity factor, performance ratio, and the error matrices. The solar PV plant supplied energy of 1325.42 MWh to the grid during the monitored period. The expected outcomes of the solar PV plant are assessed using PVGIS, PV Watts, and PV Syst simulation tools. We observed an average mean bias error (MBE) of 5.33% (PVGIS), 12.33% (PV Watts) and 30.64% (PV Syst) and average normalized mean bias error (NMBE) of 2.954% (PVGIS), 7.88% (PV watts) and 22.75% (PV Syst). Overall, it is observed that there is a deviation between the simulated and monitored energy performance. |
first_indexed | 2024-03-06T12:46:47Z |
format | Article |
id | UMPir30085 |
institution | Universiti Malaysia Pahang |
language | English |
last_indexed | 2024-03-06T12:46:47Z |
publishDate | 2020 |
publisher | Elsevier |
record_format | dspace |
spelling | UMPir300852021-10-15T08:29:31Z http://umpir.ump.edu.my/id/eprint/30085/ Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India Thotakura, Sandhya Kondamudi, Sri Chandan Xavier, J. Francis Quanjin, Ma Reddy, Guduru Ramakrishna Gangwar, Pavan Davuluri, Sri Lakshmi TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering This case study presents the performance of a megawatt-scale grid-connected rooftop solar photovoltaic (PV) plant installed on the building rooftops of an educational institute (GITAM Deemed to be University) located in coastal regions (longitude 83° 23' 6.54'' E and latitude 17° 48' 8.208'' N) of Andhra Pradesh. A framework is proposed to validate the existing simulation models that are used for PV project modeling. The validation is done by comparing the simulated performance with the real-time monitored performance. The studied PV plant consists of 3078 solar panels and 23 inverters. For the analysis, we recorded the PV plant operational data for 12 months from 1st October 2018 to 30th September 2019. Based on the monitored data and by following the proposed framework, performance analysis is carried out. The results include the estimated parameters like energy outputs, yield factor, capacity factor, performance ratio, and the error matrices. The solar PV plant supplied energy of 1325.42 MWh to the grid during the monitored period. The expected outcomes of the solar PV plant are assessed using PVGIS, PV Watts, and PV Syst simulation tools. We observed an average mean bias error (MBE) of 5.33% (PVGIS), 12.33% (PV Watts) and 30.64% (PV Syst) and average normalized mean bias error (NMBE) of 2.954% (PVGIS), 7.88% (PV watts) and 22.75% (PV Syst). Overall, it is observed that there is a deviation between the simulated and monitored energy performance. Elsevier 2020-04 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/30085/1/Operational%20performance%20of%20megawatt-scale%20grid%20integrated%20rooftop.pdf Thotakura, Sandhya and Kondamudi, Sri Chandan and Xavier, J. Francis and Quanjin, Ma and Reddy, Guduru Ramakrishna and Gangwar, Pavan and Davuluri, Sri Lakshmi (2020) Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India. Case Studies in Thermal Engineering, 18 (100602). pp. 1-11. ISSN 2214-157X. (Published) https://doi.org/10.1016/j.csite.2020.100602 https://doi.org/10.1016/j.csite.2020.100602 |
spellingShingle | TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering Thotakura, Sandhya Kondamudi, Sri Chandan Xavier, J. Francis Quanjin, Ma Reddy, Guduru Ramakrishna Gangwar, Pavan Davuluri, Sri Lakshmi Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India |
title | Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India |
title_full | Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India |
title_fullStr | Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India |
title_full_unstemmed | Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India |
title_short | Operational performance of megawatt-scale grid integrated rooftop solar PV system in tropical wet and dry climates of India |
title_sort | operational performance of megawatt scale grid integrated rooftop solar pv system in tropical wet and dry climates of india |
topic | TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering |
url | http://umpir.ump.edu.my/id/eprint/30085/1/Operational%20performance%20of%20megawatt-scale%20grid%20integrated%20rooftop.pdf |
work_keys_str_mv | AT thotakurasandhya operationalperformanceofmegawattscalegridintegratedrooftopsolarpvsystemintropicalwetanddryclimatesofindia AT kondamudisrichandan operationalperformanceofmegawattscalegridintegratedrooftopsolarpvsystemintropicalwetanddryclimatesofindia AT xavierjfrancis operationalperformanceofmegawattscalegridintegratedrooftopsolarpvsystemintropicalwetanddryclimatesofindia AT quanjinma operationalperformanceofmegawattscalegridintegratedrooftopsolarpvsystemintropicalwetanddryclimatesofindia AT reddygudururamakrishna operationalperformanceofmegawattscalegridintegratedrooftopsolarpvsystemintropicalwetanddryclimatesofindia AT gangwarpavan operationalperformanceofmegawattscalegridintegratedrooftopsolarpvsystemintropicalwetanddryclimatesofindia AT davulurisrilakshmi operationalperformanceofmegawattscalegridintegratedrooftopsolarpvsystemintropicalwetanddryclimatesofindia |