Impact of inverter controller-based grid-connected pv system in the power quality

In a Grid-Connected Photovoltaic System (GCPS), the inverters are applied for integration with the power grid. This integration brings some issues at the connection point. Therefore, grid-tied inverter control performs a vital role in feeding the power system with good power quality. This study pres...

Full description

Bibliographic Details
Main Authors: Al-Shetwi, Ali Q., Muhamad Zahim, Sujod, M. A., Hannan, Abdullahd, Majid A., Al-Ogaili, Ali Saadon, Ker, Pin Jern
Format: Article
Language:English
Published: Warsaw University of Technology 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/30969/1/Impact%20of%20inverter%20controller-based%20grid%20connected%20PV%20system.pdf
_version_ 1825813778509332480
author Al-Shetwi, Ali Q.
Muhamad Zahim, Sujod
M. A., Hannan
Abdullahd, Majid A.
Al-Ogaili, Ali Saadon
Ker, Pin Jern
author_facet Al-Shetwi, Ali Q.
Muhamad Zahim, Sujod
M. A., Hannan
Abdullahd, Majid A.
Al-Ogaili, Ali Saadon
Ker, Pin Jern
author_sort Al-Shetwi, Ali Q.
collection UMP
description In a Grid-Connected Photovoltaic System (GCPS), the inverters are applied for integration with the power grid. This integration brings some issues at the connection point. Therefore, grid-tied inverter control performs a vital role in feeding the power system with good power quality. This study presents a current-controlled Voltage Source Inverter (VSI) strategy for large-scale GCPS generates 1000 kW rated of power. The methodology and structure of the control system are presented. The power quality issues such as harmonics, voltage fluctuation, voltage unbalance, and power factor are limited at the interfacing point into the required limits as imposed by the standards. This study also discusses the controller design and the simulation results are introduced to show its effectiveness. Furthermore, the values obtained may be used to evaluate the power supply quality of various inverter controllers.
first_indexed 2024-03-06T12:49:05Z
format Article
id UMPir30969
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:49:05Z
publishDate 2020
publisher Warsaw University of Technology
record_format dspace
spelling UMPir309692021-05-17T01:42:17Z http://umpir.ump.edu.my/id/eprint/30969/ Impact of inverter controller-based grid-connected pv system in the power quality Al-Shetwi, Ali Q. Muhamad Zahim, Sujod M. A., Hannan Abdullahd, Majid A. Al-Ogaili, Ali Saadon Ker, Pin Jern TK Electrical engineering. Electronics Nuclear engineering In a Grid-Connected Photovoltaic System (GCPS), the inverters are applied for integration with the power grid. This integration brings some issues at the connection point. Therefore, grid-tied inverter control performs a vital role in feeding the power system with good power quality. This study presents a current-controlled Voltage Source Inverter (VSI) strategy for large-scale GCPS generates 1000 kW rated of power. The methodology and structure of the control system are presented. The power quality issues such as harmonics, voltage fluctuation, voltage unbalance, and power factor are limited at the interfacing point into the required limits as imposed by the standards. This study also discusses the controller design and the simulation results are introduced to show its effectiveness. Furthermore, the values obtained may be used to evaluate the power supply quality of various inverter controllers. Warsaw University of Technology 2020-11 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/30969/1/Impact%20of%20inverter%20controller-based%20grid%20connected%20PV%20system.pdf Al-Shetwi, Ali Q. and Muhamad Zahim, Sujod and M. A., Hannan and Abdullahd, Majid A. and Al-Ogaili, Ali Saadon and Ker, Pin Jern (2020) Impact of inverter controller-based grid-connected pv system in the power quality. International Journal of Electrical and Electronic Engineering and Telecommunications, 9 (6). pp. 462-469. ISSN 2319-2518. (Published) https://doi.org/10.18178/ijeetc.9.6.462-469 https://doi.org/10.18178/ijeetc.9.6.462-469
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Al-Shetwi, Ali Q.
Muhamad Zahim, Sujod
M. A., Hannan
Abdullahd, Majid A.
Al-Ogaili, Ali Saadon
Ker, Pin Jern
Impact of inverter controller-based grid-connected pv system in the power quality
title Impact of inverter controller-based grid-connected pv system in the power quality
title_full Impact of inverter controller-based grid-connected pv system in the power quality
title_fullStr Impact of inverter controller-based grid-connected pv system in the power quality
title_full_unstemmed Impact of inverter controller-based grid-connected pv system in the power quality
title_short Impact of inverter controller-based grid-connected pv system in the power quality
title_sort impact of inverter controller based grid connected pv system in the power quality
topic TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/30969/1/Impact%20of%20inverter%20controller-based%20grid%20connected%20PV%20system.pdf
work_keys_str_mv AT alshetwialiq impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality
AT muhamadzahimsujod impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality
AT mahannan impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality
AT abdullahdmajida impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality
AT alogailialisaadon impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality
AT kerpinjern impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality