Impact of inverter controller-based grid-connected pv system in the power quality
In a Grid-Connected Photovoltaic System (GCPS), the inverters are applied for integration with the power grid. This integration brings some issues at the connection point. Therefore, grid-tied inverter control performs a vital role in feeding the power system with good power quality. This study pres...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Warsaw University of Technology
2020
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/30969/1/Impact%20of%20inverter%20controller-based%20grid%20connected%20PV%20system.pdf |
_version_ | 1825813778509332480 |
---|---|
author | Al-Shetwi, Ali Q. Muhamad Zahim, Sujod M. A., Hannan Abdullahd, Majid A. Al-Ogaili, Ali Saadon Ker, Pin Jern |
author_facet | Al-Shetwi, Ali Q. Muhamad Zahim, Sujod M. A., Hannan Abdullahd, Majid A. Al-Ogaili, Ali Saadon Ker, Pin Jern |
author_sort | Al-Shetwi, Ali Q. |
collection | UMP |
description | In a Grid-Connected Photovoltaic System (GCPS), the inverters are applied for integration with the power grid. This integration brings some issues at the connection point. Therefore, grid-tied inverter control performs a vital role in feeding the power system with good power quality. This study presents a current-controlled Voltage Source Inverter (VSI) strategy for large-scale GCPS generates 1000 kW rated of power. The methodology and structure of the control system are presented. The power quality issues such as harmonics, voltage fluctuation, voltage unbalance, and power factor are limited at the interfacing point into the required limits as imposed by the standards. This study also discusses the controller design and the simulation results are introduced to show its effectiveness. Furthermore, the values obtained may be used to evaluate the power supply quality of various inverter controllers. |
first_indexed | 2024-03-06T12:49:05Z |
format | Article |
id | UMPir30969 |
institution | Universiti Malaysia Pahang |
language | English |
last_indexed | 2024-03-06T12:49:05Z |
publishDate | 2020 |
publisher | Warsaw University of Technology |
record_format | dspace |
spelling | UMPir309692021-05-17T01:42:17Z http://umpir.ump.edu.my/id/eprint/30969/ Impact of inverter controller-based grid-connected pv system in the power quality Al-Shetwi, Ali Q. Muhamad Zahim, Sujod M. A., Hannan Abdullahd, Majid A. Al-Ogaili, Ali Saadon Ker, Pin Jern TK Electrical engineering. Electronics Nuclear engineering In a Grid-Connected Photovoltaic System (GCPS), the inverters are applied for integration with the power grid. This integration brings some issues at the connection point. Therefore, grid-tied inverter control performs a vital role in feeding the power system with good power quality. This study presents a current-controlled Voltage Source Inverter (VSI) strategy for large-scale GCPS generates 1000 kW rated of power. The methodology and structure of the control system are presented. The power quality issues such as harmonics, voltage fluctuation, voltage unbalance, and power factor are limited at the interfacing point into the required limits as imposed by the standards. This study also discusses the controller design and the simulation results are introduced to show its effectiveness. Furthermore, the values obtained may be used to evaluate the power supply quality of various inverter controllers. Warsaw University of Technology 2020-11 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/30969/1/Impact%20of%20inverter%20controller-based%20grid%20connected%20PV%20system.pdf Al-Shetwi, Ali Q. and Muhamad Zahim, Sujod and M. A., Hannan and Abdullahd, Majid A. and Al-Ogaili, Ali Saadon and Ker, Pin Jern (2020) Impact of inverter controller-based grid-connected pv system in the power quality. International Journal of Electrical and Electronic Engineering and Telecommunications, 9 (6). pp. 462-469. ISSN 2319-2518. (Published) https://doi.org/10.18178/ijeetc.9.6.462-469 https://doi.org/10.18178/ijeetc.9.6.462-469 |
spellingShingle | TK Electrical engineering. Electronics Nuclear engineering Al-Shetwi, Ali Q. Muhamad Zahim, Sujod M. A., Hannan Abdullahd, Majid A. Al-Ogaili, Ali Saadon Ker, Pin Jern Impact of inverter controller-based grid-connected pv system in the power quality |
title | Impact of inverter controller-based grid-connected pv system in the power quality |
title_full | Impact of inverter controller-based grid-connected pv system in the power quality |
title_fullStr | Impact of inverter controller-based grid-connected pv system in the power quality |
title_full_unstemmed | Impact of inverter controller-based grid-connected pv system in the power quality |
title_short | Impact of inverter controller-based grid-connected pv system in the power quality |
title_sort | impact of inverter controller based grid connected pv system in the power quality |
topic | TK Electrical engineering. Electronics Nuclear engineering |
url | http://umpir.ump.edu.my/id/eprint/30969/1/Impact%20of%20inverter%20controller-based%20grid%20connected%20PV%20system.pdf |
work_keys_str_mv | AT alshetwialiq impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality AT muhamadzahimsujod impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality AT mahannan impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality AT abdullahdmajida impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality AT alogailialisaadon impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality AT kerpinjern impactofinvertercontrollerbasedgridconnectedpvsysteminthepowerquality |