Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system
Methadone Flexi Dispensing Service (MFlex) has been officially re-branded from Methadone 1Malaysia Service (M1M) since 2nd January 2019. Patients under MFlex are frequently taking their methadone according to a plan provided by pharmacist at public clinic. From the dose monitoring taken annually, ph...
Main Authors: | , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IOP Publishing
2021
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/30986/1/publication9-RDU192312.pdf |
_version_ | 1825813781381382144 |
---|---|
author | Mohd Yazid, Abu S K M, Saad M H M, Razali F, Ramlie N, Harudin W Z A, W Muhamad R, Dolah |
author_facet | Mohd Yazid, Abu S K M, Saad M H M, Razali F, Ramlie N, Harudin W Z A, W Muhamad R, Dolah |
author_sort | Mohd Yazid, Abu |
collection | UMP |
description | Methadone Flexi Dispensing Service (MFlex) has been officially re-branded from Methadone 1Malaysia Service (M1M) since 2nd January 2019. Patients under MFlex are frequently taking their methadone according to a plan provided by pharmacist at public clinic. From the dose monitoring taken annually, pharmacists can predict critical patients based on high monthly dose increases. However, the current monitoring system is written documentation with total doses that cannot accurately measure addiction levels and slow down the distribution process to appropriate incentives as provided by the government. The main objective of this work is to develop a new data monitoring system by evaluating all factors contributed to the addiction level. Mahalanobis-Taguchi System (MTS) is a method of predicting and diagnosing system performance using multivariate data in order to make quantitative decisions with the construction of a multivariate measurement scale using an analytical method. The results show that the minimum Mahalanobis Distance (MD) for healthy data is 0.2245 while the maximum is 2.3380. The minimum and maximum MD of unhealthy data is 0.6077 and 24.5719 respectively. Thus, parameters of blood, bilirubin, nitrite, specific gravity, leukocytes are considered as significant parameters by considering positive value signal-to-noise ratio (SNR) gain. Graphical user interface (GUI) has been developed for analyzing the normal and abnormal patients in detail. Meanwhile, mobile application has been developed as a decision-making tool to classify that the patients is either normal or abnormal. |
first_indexed | 2024-03-06T12:49:07Z |
format | Conference or Workshop Item |
id | UMPir30986 |
institution | Universiti Malaysia Pahang |
language | English |
last_indexed | 2024-03-06T12:49:07Z |
publishDate | 2021 |
publisher | IOP Publishing |
record_format | dspace |
spelling | UMPir309862021-04-20T04:13:01Z http://umpir.ump.edu.my/id/eprint/30986/ Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system Mohd Yazid, Abu S K M, Saad M H M, Razali F, Ramlie N, Harudin W Z A, W Muhamad R, Dolah TS Manufactures Methadone Flexi Dispensing Service (MFlex) has been officially re-branded from Methadone 1Malaysia Service (M1M) since 2nd January 2019. Patients under MFlex are frequently taking their methadone according to a plan provided by pharmacist at public clinic. From the dose monitoring taken annually, pharmacists can predict critical patients based on high monthly dose increases. However, the current monitoring system is written documentation with total doses that cannot accurately measure addiction levels and slow down the distribution process to appropriate incentives as provided by the government. The main objective of this work is to develop a new data monitoring system by evaluating all factors contributed to the addiction level. Mahalanobis-Taguchi System (MTS) is a method of predicting and diagnosing system performance using multivariate data in order to make quantitative decisions with the construction of a multivariate measurement scale using an analytical method. The results show that the minimum Mahalanobis Distance (MD) for healthy data is 0.2245 while the maximum is 2.3380. The minimum and maximum MD of unhealthy data is 0.6077 and 24.5719 respectively. Thus, parameters of blood, bilirubin, nitrite, specific gravity, leukocytes are considered as significant parameters by considering positive value signal-to-noise ratio (SNR) gain. Graphical user interface (GUI) has been developed for analyzing the normal and abnormal patients in detail. Meanwhile, mobile application has been developed as a decision-making tool to classify that the patients is either normal or abnormal. IOP Publishing 2021 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/30986/1/publication9-RDU192312.pdf Mohd Yazid, Abu and S K M, Saad and M H M, Razali and F, Ramlie and N, Harudin and W Z A, W Muhamad and R, Dolah (2021) Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system. In: The 2nd International Conference on Innovative Technology, Engineering and Sciences (iCITES 2020) , Pekan Pahang , 22-23 December 2020. pp. 1-10.. ISSN 1757-8981 (Print); 1757-899X (Online) (Published) https://doi.org/10.1088/1757-899X/1092/1/012009 |
spellingShingle | TS Manufactures Mohd Yazid, Abu S K M, Saad M H M, Razali F, Ramlie N, Harudin W Z A, W Muhamad R, Dolah Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system |
title | Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system |
title_full | Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system |
title_fullStr | Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system |
title_full_unstemmed | Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system |
title_short | Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system |
title_sort | optimizing the mflex monitoring system using mahalanobis taguchi system |
topic | TS Manufactures |
url | http://umpir.ump.edu.my/id/eprint/30986/1/publication9-RDU192312.pdf |
work_keys_str_mv | AT mohdyazidabu optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem AT skmsaad optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem AT mhmrazali optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem AT framlie optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem AT nharudin optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem AT wzawmuhamad optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem AT rdolah optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem |