Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system

Methadone Flexi Dispensing Service (MFlex) has been officially re-branded from Methadone 1Malaysia Service (M1M) since 2nd January 2019. Patients under MFlex are frequently taking their methadone according to a plan provided by pharmacist at public clinic. From the dose monitoring taken annually, ph...

Full description

Bibliographic Details
Main Authors: Mohd Yazid, Abu, S K M, Saad, M H M, Razali, F, Ramlie, N, Harudin, W Z A, W Muhamad, R, Dolah
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/30986/1/publication9-RDU192312.pdf
_version_ 1825813781381382144
author Mohd Yazid, Abu
S K M, Saad
M H M, Razali
F, Ramlie
N, Harudin
W Z A, W Muhamad
R, Dolah
author_facet Mohd Yazid, Abu
S K M, Saad
M H M, Razali
F, Ramlie
N, Harudin
W Z A, W Muhamad
R, Dolah
author_sort Mohd Yazid, Abu
collection UMP
description Methadone Flexi Dispensing Service (MFlex) has been officially re-branded from Methadone 1Malaysia Service (M1M) since 2nd January 2019. Patients under MFlex are frequently taking their methadone according to a plan provided by pharmacist at public clinic. From the dose monitoring taken annually, pharmacists can predict critical patients based on high monthly dose increases. However, the current monitoring system is written documentation with total doses that cannot accurately measure addiction levels and slow down the distribution process to appropriate incentives as provided by the government. The main objective of this work is to develop a new data monitoring system by evaluating all factors contributed to the addiction level. Mahalanobis-Taguchi System (MTS) is a method of predicting and diagnosing system performance using multivariate data in order to make quantitative decisions with the construction of a multivariate measurement scale using an analytical method. The results show that the minimum Mahalanobis Distance (MD) for healthy data is 0.2245 while the maximum is 2.3380. The minimum and maximum MD of unhealthy data is 0.6077 and 24.5719 respectively. Thus, parameters of blood, bilirubin, nitrite, specific gravity, leukocytes are considered as significant parameters by considering positive value signal-to-noise ratio (SNR) gain. Graphical user interface (GUI) has been developed for analyzing the normal and abnormal patients in detail. Meanwhile, mobile application has been developed as a decision-making tool to classify that the patients is either normal or abnormal.
first_indexed 2024-03-06T12:49:07Z
format Conference or Workshop Item
id UMPir30986
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:49:07Z
publishDate 2021
publisher IOP Publishing
record_format dspace
spelling UMPir309862021-04-20T04:13:01Z http://umpir.ump.edu.my/id/eprint/30986/ Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system Mohd Yazid, Abu S K M, Saad M H M, Razali F, Ramlie N, Harudin W Z A, W Muhamad R, Dolah TS Manufactures Methadone Flexi Dispensing Service (MFlex) has been officially re-branded from Methadone 1Malaysia Service (M1M) since 2nd January 2019. Patients under MFlex are frequently taking their methadone according to a plan provided by pharmacist at public clinic. From the dose monitoring taken annually, pharmacists can predict critical patients based on high monthly dose increases. However, the current monitoring system is written documentation with total doses that cannot accurately measure addiction levels and slow down the distribution process to appropriate incentives as provided by the government. The main objective of this work is to develop a new data monitoring system by evaluating all factors contributed to the addiction level. Mahalanobis-Taguchi System (MTS) is a method of predicting and diagnosing system performance using multivariate data in order to make quantitative decisions with the construction of a multivariate measurement scale using an analytical method. The results show that the minimum Mahalanobis Distance (MD) for healthy data is 0.2245 while the maximum is 2.3380. The minimum and maximum MD of unhealthy data is 0.6077 and 24.5719 respectively. Thus, parameters of blood, bilirubin, nitrite, specific gravity, leukocytes are considered as significant parameters by considering positive value signal-to-noise ratio (SNR) gain. Graphical user interface (GUI) has been developed for analyzing the normal and abnormal patients in detail. Meanwhile, mobile application has been developed as a decision-making tool to classify that the patients is either normal or abnormal. IOP Publishing 2021 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/30986/1/publication9-RDU192312.pdf Mohd Yazid, Abu and S K M, Saad and M H M, Razali and F, Ramlie and N, Harudin and W Z A, W Muhamad and R, Dolah (2021) Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system. In: The 2nd International Conference on Innovative Technology, Engineering and Sciences (iCITES 2020) , Pekan Pahang , 22-23 December 2020. pp. 1-10.. ISSN 1757-8981 (Print); 1757-899X (Online) (Published) https://doi.org/10.1088/1757-899X/1092/1/012009
spellingShingle TS Manufactures
Mohd Yazid, Abu
S K M, Saad
M H M, Razali
F, Ramlie
N, Harudin
W Z A, W Muhamad
R, Dolah
Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system
title Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system
title_full Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system
title_fullStr Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system
title_full_unstemmed Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system
title_short Optimizing the MFlex monitoring system using Mahalanobis-Taguchi system
title_sort optimizing the mflex monitoring system using mahalanobis taguchi system
topic TS Manufactures
url http://umpir.ump.edu.my/id/eprint/30986/1/publication9-RDU192312.pdf
work_keys_str_mv AT mohdyazidabu optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem
AT skmsaad optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem
AT mhmrazali optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem
AT framlie optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem
AT nharudin optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem
AT wzawmuhamad optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem
AT rdolah optimizingthemflexmonitoringsystemusingmahalanobistaguchisystem