Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment

Background: The study aims to analyze the correlation between the maximal diameter (both axial and orthogonal) and volume changes in the true (TL) and false lumens (FL) after stent-grafting for Stanford type B aortic dissection. Method: Computed tomography angiography was performed on 13 type B aort...

Full description

Bibliographic Details
Main Authors: Wan Naimah, Wan Ab Naim, Sun, Zhonghua, Liew, Yih Miin, Chan, Bee Ting, Jansen, Shirley, Lei, Jing, Poo Balan, Ganesan, Shahrul Amry, Hashim, Ganiga Srinivasaiah, Sridhar, Lim, Einly
Format: Article
Language:English
Published: AME Publishing Company 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/31364/1/Comparison%20of%20diametric%20and%20volumetric%20changes%20in%20Stanford%20type%20B.pdf
_version_ 1825813847111368704
author Wan Naimah, Wan Ab Naim
Sun, Zhonghua
Liew, Yih Miin
Chan, Bee Ting
Jansen, Shirley
Lei, Jing
Poo Balan, Ganesan
Shahrul Amry, Hashim
Ganiga Srinivasaiah, Sridhar
Lim, Einly
author_facet Wan Naimah, Wan Ab Naim
Sun, Zhonghua
Liew, Yih Miin
Chan, Bee Ting
Jansen, Shirley
Lei, Jing
Poo Balan, Ganesan
Shahrul Amry, Hashim
Ganiga Srinivasaiah, Sridhar
Lim, Einly
author_sort Wan Naimah, Wan Ab Naim
collection UMP
description Background: The study aims to analyze the correlation between the maximal diameter (both axial and orthogonal) and volume changes in the true (TL) and false lumens (FL) after stent-grafting for Stanford type B aortic dissection. Method: Computed tomography angiography was performed on 13 type B aortic dissection patients before and after procedure, and at 6 and 12 months follow-up. The lumens were divided into three regions: the stented area (Region 1), distal to the stent graft to the celiac artery (Region 2), and between the celiac artery and the iliac bifurcation (Region 3). Changes in aortic morphology were quantified by the increase or decrease of diametric and volumetric percentages from baseline measurements. Results: At Region 1, the TL diameter and volume increased (pre-treatment: volume =51.4±41.9 mL, maximal axial diameter =22.4±6.8 mm, maximal orthogonal diameter =21.6±7.2 mm; follow-up: volume =130.7±69.2 mL, maximal axial diameter =40.1±8.1 mm, maximal orthogonal diameter =31.9+2.6 mm, P<0.05 for all comparisons), while FL decreased (pre-treatment: volume =129.6±150.5 mL; maximal axial diameter =43.0±15.8 mm; maximal orthogonal diameter =28.3±12.6 mm; follow-up: volume =66.6±95.0 mL, maximal axial diameter =24.5±19.9 mm, maximal orthogonal diameter =16.9±13.7, P<0.05 for all comparisons). Due to the uniformity in size throughout the vessel, high concordance was observed between diametric and volumetric measurements in the stented region with 93% and 92% between maximal axial diameter and volume for the true/false lumens, and 90% and 92% between maximal orthogonal diameter and volume for the true/false lumens. Large discrepancies were observed between the different measurement methods at regions distal to the stent graft, with up to 46% differences between maximal orthogonal diameter and volume. Conclusions: Volume measurement was shown to be a much more sensitive indicator in identifying lumen expansion/shrinkage at the distal stented region.
first_indexed 2024-03-06T12:50:06Z
format Article
id UMPir31364
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:50:06Z
publishDate 2021
publisher AME Publishing Company
record_format dspace
spelling UMPir313642021-07-09T02:27:39Z http://umpir.ump.edu.my/id/eprint/31364/ Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment Wan Naimah, Wan Ab Naim Sun, Zhonghua Liew, Yih Miin Chan, Bee Ting Jansen, Shirley Lei, Jing Poo Balan, Ganesan Shahrul Amry, Hashim Ganiga Srinivasaiah, Sridhar Lim, Einly RC Internal medicine RD Surgery Background: The study aims to analyze the correlation between the maximal diameter (both axial and orthogonal) and volume changes in the true (TL) and false lumens (FL) after stent-grafting for Stanford type B aortic dissection. Method: Computed tomography angiography was performed on 13 type B aortic dissection patients before and after procedure, and at 6 and 12 months follow-up. The lumens were divided into three regions: the stented area (Region 1), distal to the stent graft to the celiac artery (Region 2), and between the celiac artery and the iliac bifurcation (Region 3). Changes in aortic morphology were quantified by the increase or decrease of diametric and volumetric percentages from baseline measurements. Results: At Region 1, the TL diameter and volume increased (pre-treatment: volume =51.4±41.9 mL, maximal axial diameter =22.4±6.8 mm, maximal orthogonal diameter =21.6±7.2 mm; follow-up: volume =130.7±69.2 mL, maximal axial diameter =40.1±8.1 mm, maximal orthogonal diameter =31.9+2.6 mm, P<0.05 for all comparisons), while FL decreased (pre-treatment: volume =129.6±150.5 mL; maximal axial diameter =43.0±15.8 mm; maximal orthogonal diameter =28.3±12.6 mm; follow-up: volume =66.6±95.0 mL, maximal axial diameter =24.5±19.9 mm, maximal orthogonal diameter =16.9±13.7, P<0.05 for all comparisons). Due to the uniformity in size throughout the vessel, high concordance was observed between diametric and volumetric measurements in the stented region with 93% and 92% between maximal axial diameter and volume for the true/false lumens, and 90% and 92% between maximal orthogonal diameter and volume for the true/false lumens. Large discrepancies were observed between the different measurement methods at regions distal to the stent graft, with up to 46% differences between maximal orthogonal diameter and volume. Conclusions: Volume measurement was shown to be a much more sensitive indicator in identifying lumen expansion/shrinkage at the distal stented region. AME Publishing Company 2021-05 Article PeerReviewed pdf en cc_by_nc_nd_4 http://umpir.ump.edu.my/id/eprint/31364/1/Comparison%20of%20diametric%20and%20volumetric%20changes%20in%20Stanford%20type%20B.pdf Wan Naimah, Wan Ab Naim and Sun, Zhonghua and Liew, Yih Miin and Chan, Bee Ting and Jansen, Shirley and Lei, Jing and Poo Balan, Ganesan and Shahrul Amry, Hashim and Ganiga Srinivasaiah, Sridhar and Lim, Einly (2021) Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment. Quantitative Imaging in Medicine and Surgery, 11 (5). pp. 1723-1736. ISSN 2223-4292. (Published) http://dx.doi.org/10.21037/qims-20-814 http://dx.doi.org/10.21037/qims-20-814
spellingShingle RC Internal medicine
RD Surgery
Wan Naimah, Wan Ab Naim
Sun, Zhonghua
Liew, Yih Miin
Chan, Bee Ting
Jansen, Shirley
Lei, Jing
Poo Balan, Ganesan
Shahrul Amry, Hashim
Ganiga Srinivasaiah, Sridhar
Lim, Einly
Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment
title Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment
title_full Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment
title_fullStr Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment
title_full_unstemmed Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment
title_short Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment
title_sort comparison of diametric and volumetric changes in stanford type b aortic dissection patients in assessing aortic remodeling post stent graft treatment
topic RC Internal medicine
RD Surgery
url http://umpir.ump.edu.my/id/eprint/31364/1/Comparison%20of%20diametric%20and%20volumetric%20changes%20in%20Stanford%20type%20B.pdf
work_keys_str_mv AT wannaimahwanabnaim comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT sunzhonghua comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT liewyihmiin comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT chanbeeting comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT jansenshirley comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT leijing comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT poobalanganesan comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT shahrulamryhashim comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT ganigasrinivasaiahsridhar comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment
AT limeinly comparisonofdiametricandvolumetricchangesinstanfordtypebaorticdissectionpatientsinassessingaorticremodelingpoststentgrafttreatment