Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application

This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show tha...

Full description

Bibliographic Details
Main Authors: A., Shah, Siti Nurul Fasehah, ., Mas Ayu, Hassan, Rosdi, Daud, Che Ghani, Che Kob
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/33334/1/Improvement%20of%20Corrosion%20Resistance%20of%20Tin%20Coated.pdf
_version_ 1796994950658785280
author A., Shah
Siti Nurul Fasehah, .
Mas Ayu, Hassan
Rosdi, Daud
Che Ghani, Che Kob
author_facet A., Shah
Siti Nurul Fasehah, .
Mas Ayu, Hassan
Rosdi, Daud
Che Ghani, Che Kob
author_sort A., Shah
collection UMP
description This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show that all coated samples treated with ultrasonic vibration improve the surface of the coated sample and produce a compact coating as compared with a substrate coated without mechanical treatment. The corrosion test evaluated by Potentiodynamic polarization and Electrochemical Impedance Spectroscopy indicated that all coated samples treated with mechanical treatment showed high corrosion resistance as compared with the untreated sample. It can be concluded that mechanical treatment which is a simple technic can be used as an alternative to improve the corrosion resistance thus reduce the implant and manufacturing cost for biomedical applications.
first_indexed 2024-03-06T12:55:08Z
format Conference or Workshop Item
id UMPir33334
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T12:55:08Z
publishDate 2021
publisher IOP Publishing
record_format dspace
spelling UMPir333342023-12-19T06:30:28Z http://umpir.ump.edu.my/id/eprint/33334/ Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application A., Shah Siti Nurul Fasehah, . Mas Ayu, Hassan Rosdi, Daud Che Ghani, Che Kob TJ Mechanical engineering and machinery TS Manufactures This work aims to study the effect of mechanical treatment technique on titanium coated with PVD for the enhancement of corrosion resistance for the biomedical implant. First, substrates were coated with TiN via PVD then applied the mechanical treatment through ultrasonic vibration. Results show that all coated samples treated with ultrasonic vibration improve the surface of the coated sample and produce a compact coating as compared with a substrate coated without mechanical treatment. The corrosion test evaluated by Potentiodynamic polarization and Electrochemical Impedance Spectroscopy indicated that all coated samples treated with mechanical treatment showed high corrosion resistance as compared with the untreated sample. It can be concluded that mechanical treatment which is a simple technic can be used as an alternative to improve the corrosion resistance thus reduce the implant and manufacturing cost for biomedical applications. IOP Publishing 2021 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/33334/1/Improvement%20of%20Corrosion%20Resistance%20of%20Tin%20Coated.pdf A., Shah and Siti Nurul Fasehah, . and Mas Ayu, Hassan and Rosdi, Daud and Che Ghani, Che Kob (2021) Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application. In: Journal of Physics: Conference Series; 2nd UPY International Conference on Applied Science and Education, UPINCASE 2020 , 3 - 4 November 2020 , Yogyakarta, Virtual. pp. 1-10., 1823 (1). ISSN 1742-6588 https://doi.org/10.1088/1742-6596/1823/1/012111 https://doi.org/10.1088/1742-6596/1823/1/012111
spellingShingle TJ Mechanical engineering and machinery
TS Manufactures
A., Shah
Siti Nurul Fasehah, .
Mas Ayu, Hassan
Rosdi, Daud
Che Ghani, Che Kob
Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_full Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_fullStr Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_full_unstemmed Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_short Improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
title_sort improvement of corrosion resistance of tin coated on titanium alloy for biomedical application
topic TJ Mechanical engineering and machinery
TS Manufactures
url http://umpir.ump.edu.my/id/eprint/33334/1/Improvement%20of%20Corrosion%20Resistance%20of%20Tin%20Coated.pdf
work_keys_str_mv AT ashah improvementofcorrosionresistanceoftincoatedontitaniumalloyforbiomedicalapplication
AT sitinurulfasehah improvementofcorrosionresistanceoftincoatedontitaniumalloyforbiomedicalapplication
AT masayuhassan improvementofcorrosionresistanceoftincoatedontitaniumalloyforbiomedicalapplication
AT rosdidaud improvementofcorrosionresistanceoftincoatedontitaniumalloyforbiomedicalapplication
AT cheghanichekob improvementofcorrosionresistanceoftincoatedontitaniumalloyforbiomedicalapplication