Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery
Cardiovascular disease is number one causes of morbidity and mortality in global. In-vitro studies are widely applied in the investigation of blood flow under pathological conditions to diagnose atherosclerosis in carotid arteries. In this manuscript, a brief review on the latest published articles...
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
Springer Science and Business Media Deutschland GmbH
2022
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/37897/2/Brief%20review%20on%20recent%20technology%20in%20particle%20image%20velocimetry%20studies%20on%20hemodynamics%20.pdf http://umpir.ump.edu.my/id/eprint/37897/3/Brief%20review%20on%20recent%20technology%20in%20particle%20image.pdf |
_version_ | 1796995770746929152 |
---|---|
author | A. Fahmi Huwaidi, M. Noor Nasrul Hadi, Johari |
author_facet | A. Fahmi Huwaidi, M. Noor Nasrul Hadi, Johari |
author_sort | A. Fahmi Huwaidi, M. Noor |
collection | UMP |
description | Cardiovascular disease is number one causes of morbidity and mortality in global. In-vitro studies are widely applied in the investigation of blood flow under pathological conditions to diagnose atherosclerosis in carotid arteries. In this manuscript, a brief review on the latest published articles was con ducted according to Preferred Reporting Items for Systematic Reviews and Me ta-Analyses on the particle image velocimetry (PIV) studies of blood flow in carotid artery geometries. Fourteen (14) recent articles on PIV from 2016 to 2020 in Scopus, PubMed and ScienceDirect databases were included. The data of the published articles were focused on the technical aspects of PIV flow measurement and were organized in two categories i.e. carotid phantom geometries constructions and the blood mimicking flow circuits. This systematic re view paper summarises the updated methodology in the PIV and identify potential areas to elucidate the accuracy and limitations of each method. |
first_indexed | 2024-03-06T13:07:10Z |
format | Conference or Workshop Item |
id | UMPir37897 |
institution | Universiti Malaysia Pahang |
language | English English |
last_indexed | 2024-03-06T13:07:10Z |
publishDate | 2022 |
publisher | Springer Science and Business Media Deutschland GmbH |
record_format | dspace |
spelling | UMPir378972023-07-12T07:53:04Z http://umpir.ump.edu.my/id/eprint/37897/ Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery A. Fahmi Huwaidi, M. Noor Nasrul Hadi, Johari R Medicine (General) T Technology (General) TJ Mechanical engineering and machinery Cardiovascular disease is number one causes of morbidity and mortality in global. In-vitro studies are widely applied in the investigation of blood flow under pathological conditions to diagnose atherosclerosis in carotid arteries. In this manuscript, a brief review on the latest published articles was con ducted according to Preferred Reporting Items for Systematic Reviews and Me ta-Analyses on the particle image velocimetry (PIV) studies of blood flow in carotid artery geometries. Fourteen (14) recent articles on PIV from 2016 to 2020 in Scopus, PubMed and ScienceDirect databases were included. The data of the published articles were focused on the technical aspects of PIV flow measurement and were organized in two categories i.e. carotid phantom geometries constructions and the blood mimicking flow circuits. This systematic re view paper summarises the updated methodology in the PIV and identify potential areas to elucidate the accuracy and limitations of each method. Springer Science and Business Media Deutschland GmbH 2022 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/37897/2/Brief%20review%20on%20recent%20technology%20in%20particle%20image%20velocimetry%20studies%20on%20hemodynamics%20.pdf pdf en http://umpir.ump.edu.my/id/eprint/37897/3/Brief%20review%20on%20recent%20technology%20in%20particle%20image.pdf A. Fahmi Huwaidi, M. Noor and Nasrul Hadi, Johari (2022) Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery. In: Human Engineering Symposium, HUMENS 2021 , 22 February 2021 - 22 February 2021 , Virtual Online. pp. 267-277. (266559). ISSN 21954356 ISBN 9789811641145 https://doi.org/10.1007/978-981-16-4115-2_21 |
spellingShingle | R Medicine (General) T Technology (General) TJ Mechanical engineering and machinery A. Fahmi Huwaidi, M. Noor Nasrul Hadi, Johari Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery |
title | Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery |
title_full | Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery |
title_fullStr | Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery |
title_full_unstemmed | Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery |
title_short | Brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery |
title_sort | brief review on recent technology in particle image velocimetry studies on hemodynamics in carotid artery |
topic | R Medicine (General) T Technology (General) TJ Mechanical engineering and machinery |
url | http://umpir.ump.edu.my/id/eprint/37897/2/Brief%20review%20on%20recent%20technology%20in%20particle%20image%20velocimetry%20studies%20on%20hemodynamics%20.pdf http://umpir.ump.edu.my/id/eprint/37897/3/Brief%20review%20on%20recent%20technology%20in%20particle%20image.pdf |
work_keys_str_mv | AT afahmihuwaidimnoor briefreviewonrecenttechnologyinparticleimagevelocimetrystudiesonhemodynamicsincarotidartery AT nasrulhadijohari briefreviewonrecenttechnologyinparticleimagevelocimetrystudiesonhemodynamicsincarotidartery |