Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes

Electrical capacitance tomography (ECT) is a common imaging technique in process tomography that has been used in various applications especially in pipe applications. It works by measuring the dielectric permittivity distribution in the interior of pipe using capacitive sensors. Based on the princi...

Full description

Bibliographic Details
Main Authors: Ain Eazriena, Che Man, Yasmin, Abdul Wahab, Nurhafizah, Abu Talip, Suzanna, Ridzuan Aw, Mohd Mawardi, Saari, Ruzairi, Abdul Rahim, Sia, Yee Yu
Format: Conference or Workshop Item
Language:English
English
Published: IET 2022
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/38530/1/%5BPublish%5DSimulation_of_frequency_selection_for_invasive.pdf
http://umpir.ump.edu.my/id/eprint/38530/7/Simulation%20of%20frequency%20selection%20for%20invasive%20approach%20of%20electrical%20capacitance%20.pdf
_version_ 1796995882788323328
author Ain Eazriena, Che Man
Yasmin, Abdul Wahab
Nurhafizah, Abu Talip
Suzanna, Ridzuan Aw
Mohd Mawardi, Saari
Ruzairi, Abdul Rahim
Sia, Yee Yu
author_facet Ain Eazriena, Che Man
Yasmin, Abdul Wahab
Nurhafizah, Abu Talip
Suzanna, Ridzuan Aw
Mohd Mawardi, Saari
Ruzairi, Abdul Rahim
Sia, Yee Yu
author_sort Ain Eazriena, Che Man
collection UMP
description Electrical capacitance tomography (ECT) is a common imaging technique in process tomography that has been used in various applications especially in pipe applications. It works by measuring the dielectric permittivity distribution in the interior of pipe using capacitive sensors. Based on the principle of ECT, signals are generated from transmitter and delivered to the right receiver using certain frequency. Assuming random selection of frequency could affect the wanted signal at the receivers, this paper will analyse the frequency selection ranged from 100 to 500 kHz with increment of 50 kHz thoroughly. The objective of this paper is to select the right frequency for the invasive approach of ECT for the conducting pipe applications using common parameter in ECT and oil-gas regimes as a medium. The frequency selection is observed using the voltage reading at each of the receivers and simulated using COMSOL Multiphysics software. Based on the results, the optimal frequency selection is 400 kHz where the best coverage area of sensor is 90%. This selection has the highest value of electrical voltage among other range proposed while the least electrical voltage produce is at frequency 300 kHz and coverage area of 50%.
first_indexed 2024-03-06T13:08:49Z
format Conference or Workshop Item
id UMPir38530
institution Universiti Malaysia Pahang
language English
English
last_indexed 2024-03-06T13:08:49Z
publishDate 2022
publisher IET
record_format dspace
spelling UMPir385302023-09-06T07:29:20Z http://umpir.ump.edu.my/id/eprint/38530/ Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes Ain Eazriena, Che Man Yasmin, Abdul Wahab Nurhafizah, Abu Talip Suzanna, Ridzuan Aw Mohd Mawardi, Saari Ruzairi, Abdul Rahim Sia, Yee Yu TK Electrical engineering. Electronics Nuclear engineering Electrical capacitance tomography (ECT) is a common imaging technique in process tomography that has been used in various applications especially in pipe applications. It works by measuring the dielectric permittivity distribution in the interior of pipe using capacitive sensors. Based on the principle of ECT, signals are generated from transmitter and delivered to the right receiver using certain frequency. Assuming random selection of frequency could affect the wanted signal at the receivers, this paper will analyse the frequency selection ranged from 100 to 500 kHz with increment of 50 kHz thoroughly. The objective of this paper is to select the right frequency for the invasive approach of ECT for the conducting pipe applications using common parameter in ECT and oil-gas regimes as a medium. The frequency selection is observed using the voltage reading at each of the receivers and simulated using COMSOL Multiphysics software. Based on the results, the optimal frequency selection is 400 kHz where the best coverage area of sensor is 90%. This selection has the highest value of electrical voltage among other range proposed while the least electrical voltage produce is at frequency 300 kHz and coverage area of 50%. IET 2022 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/38530/1/%5BPublish%5DSimulation_of_frequency_selection_for_invasive.pdf pdf en http://umpir.ump.edu.my/id/eprint/38530/7/Simulation%20of%20frequency%20selection%20for%20invasive%20approach%20of%20electrical%20capacitance%20.pdf Ain Eazriena, Che Man and Yasmin, Abdul Wahab and Nurhafizah, Abu Talip and Suzanna, Ridzuan Aw and Mohd Mawardi, Saari and Ruzairi, Abdul Rahim and Sia, Yee Yu (2022) Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes. In: Engineering Technology International Conference (ETIC 2022) , 7 - 8 September 2022 , Virtually hosted by Universiti Malaysia Pahang. pp. 63-68.. ISBN 978-1-83953-782-0 https://doi.org/10.1049/icp.2022.2571
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ain Eazriena, Che Man
Yasmin, Abdul Wahab
Nurhafizah, Abu Talip
Suzanna, Ridzuan Aw
Mohd Mawardi, Saari
Ruzairi, Abdul Rahim
Sia, Yee Yu
Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes
title Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes
title_full Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes
title_fullStr Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes
title_full_unstemmed Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes
title_short Simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil-gas regimes
title_sort simulation of frequency selection for invasive approach of electrical capacitance tomography for conducting pipe application using oil gas regimes
topic TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/38530/1/%5BPublish%5DSimulation_of_frequency_selection_for_invasive.pdf
http://umpir.ump.edu.my/id/eprint/38530/7/Simulation%20of%20frequency%20selection%20for%20invasive%20approach%20of%20electrical%20capacitance%20.pdf
work_keys_str_mv AT aineazrienacheman simulationoffrequencyselectionforinvasiveapproachofelectricalcapacitancetomographyforconductingpipeapplicationusingoilgasregimes
AT yasminabdulwahab simulationoffrequencyselectionforinvasiveapproachofelectricalcapacitancetomographyforconductingpipeapplicationusingoilgasregimes
AT nurhafizahabutalip simulationoffrequencyselectionforinvasiveapproachofelectricalcapacitancetomographyforconductingpipeapplicationusingoilgasregimes
AT suzannaridzuanaw simulationoffrequencyselectionforinvasiveapproachofelectricalcapacitancetomographyforconductingpipeapplicationusingoilgasregimes
AT mohdmawardisaari simulationoffrequencyselectionforinvasiveapproachofelectricalcapacitancetomographyforconductingpipeapplicationusingoilgasregimes
AT ruzairiabdulrahim simulationoffrequencyselectionforinvasiveapproachofelectricalcapacitancetomographyforconductingpipeapplicationusingoilgasregimes
AT siayeeyu simulationoffrequencyselectionforinvasiveapproachofelectricalcapacitancetomographyforconductingpipeapplicationusingoilgasregimes