Modeling bearing temperature of DC machine in no-load condition using transfer function

Bearing is a critical component in an electrical machine which get continuous monitoring and included in scheduled predictive maintenance. The temperature of the bearing is a valuable information that may allow early fault detection, lubrication assessment, and overloading indication of the system d...

Full description

Bibliographic Details
Main Authors: M. S., Mat Jahak, M. A. H., Rasid
Format: Conference or Workshop Item
Language:English
English
English
Published: Springer 2024
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/38565/7/Modeling%20bearing%20temperature%20of%20DC%20machine%20in%20no-load%20condition%20.pdf
http://umpir.ump.edu.my/id/eprint/38565/13/Modeling%20Bearing%20Temperature%20of%20DC%20Machine.pdf
http://umpir.ump.edu.my/id/eprint/38565/14/Modeling%20Bearing%20Temperature%20of%20DC%20Machine%20in%20No-Load%20Condition%20Using%20Transfer%20Function.pdf
_version_ 1825815134036033536
author M. S., Mat Jahak
M. A. H., Rasid
author_facet M. S., Mat Jahak
M. A. H., Rasid
author_sort M. S., Mat Jahak
collection UMP
description Bearing is a critical component in an electrical machine which get continuous monitoring and included in scheduled predictive maintenance. The temperature of the bearing is a valuable information that may allow early fault detection, lubrication assessment, and overloading indication of the system driven. Using the temperature measurement of the bearing and comparing it to a baseline temperature in real time will allow early warning of any eventual fault. This paper proposes a thermal model for the bearing in a brushed DC machine, developed using transfer function that will predict the temperature increase contributed specifically by speed variation. The transfer function was found by identification using experimental temperature of the bearing at a speed ranging from 20 to 100% of its rated speed while being at no load. The result shows that the first-order transfer function was found to be the best with a model identification MSE of less than 0.23. The slight variation on the poles of the system indicates that the thermal system of the bearing inside an electrical machine does not obey exactly the LTI hypothesis.
first_indexed 2024-09-25T03:47:45Z
format Conference or Workshop Item
id UMPir38565
institution Universiti Malaysia Pahang
language English
English
English
last_indexed 2024-09-25T03:47:45Z
publishDate 2024
publisher Springer
record_format dspace
spelling UMPir385652024-05-24T02:07:36Z http://umpir.ump.edu.my/id/eprint/38565/ Modeling bearing temperature of DC machine in no-load condition using transfer function M. S., Mat Jahak M. A. H., Rasid TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering Bearing is a critical component in an electrical machine which get continuous monitoring and included in scheduled predictive maintenance. The temperature of the bearing is a valuable information that may allow early fault detection, lubrication assessment, and overloading indication of the system driven. Using the temperature measurement of the bearing and comparing it to a baseline temperature in real time will allow early warning of any eventual fault. This paper proposes a thermal model for the bearing in a brushed DC machine, developed using transfer function that will predict the temperature increase contributed specifically by speed variation. The transfer function was found by identification using experimental temperature of the bearing at a speed ranging from 20 to 100% of its rated speed while being at no load. The result shows that the first-order transfer function was found to be the best with a model identification MSE of less than 0.23. The slight variation on the poles of the system indicates that the thermal system of the bearing inside an electrical machine does not obey exactly the LTI hypothesis. Springer 2024-08-07 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/38565/7/Modeling%20bearing%20temperature%20of%20DC%20machine%20in%20no-load%20condition%20.pdf pdf en http://umpir.ump.edu.my/id/eprint/38565/13/Modeling%20Bearing%20Temperature%20of%20DC%20Machine.pdf pdf en http://umpir.ump.edu.my/id/eprint/38565/14/Modeling%20Bearing%20Temperature%20of%20DC%20Machine%20in%20No-Load%20Condition%20Using%20Transfer%20Function.pdf M. S., Mat Jahak and M. A. H., Rasid (2024) Modeling bearing temperature of DC machine in no-load condition using transfer function. In: Intelligent Manufacturing and Mechatronics, Lecture Notes in Networks and Systems. 4th International conference on Innovative Manufacturing, Mechatronics and Materials Forum, iM3F2023 , 07 – 08 August 2023 , Pekan, Malaysia. pp. 239-249., 850. ISSN 2367-3389 ISBN 978-981-99-8819-8 (Published) https://doi.org/10.1007/978-981-99-8819-8_19
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
M. S., Mat Jahak
M. A. H., Rasid
Modeling bearing temperature of DC machine in no-load condition using transfer function
title Modeling bearing temperature of DC machine in no-load condition using transfer function
title_full Modeling bearing temperature of DC machine in no-load condition using transfer function
title_fullStr Modeling bearing temperature of DC machine in no-load condition using transfer function
title_full_unstemmed Modeling bearing temperature of DC machine in no-load condition using transfer function
title_short Modeling bearing temperature of DC machine in no-load condition using transfer function
title_sort modeling bearing temperature of dc machine in no load condition using transfer function
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/38565/7/Modeling%20bearing%20temperature%20of%20DC%20machine%20in%20no-load%20condition%20.pdf
http://umpir.ump.edu.my/id/eprint/38565/13/Modeling%20Bearing%20Temperature%20of%20DC%20Machine.pdf
http://umpir.ump.edu.my/id/eprint/38565/14/Modeling%20Bearing%20Temperature%20of%20DC%20Machine%20in%20No-Load%20Condition%20Using%20Transfer%20Function.pdf
work_keys_str_mv AT msmatjahak modelingbearingtemperatureofdcmachineinnoloadconditionusingtransferfunction
AT mahrasid modelingbearingtemperatureofdcmachineinnoloadconditionusingtransferfunction