Performance Investigation of R32 and R410a Refrigerants with Different Compressor Lubricants

The present study aims to investigate the effect of changing air conditioning refrigerants and compressor lubricants on system performance. Two types of refrigerants namely R410a and R32 paired with two different lubricants were investigated. A test rig consists of residential air conditioning with...

ver descrição completa

Detalhes bibliográficos
Principais autores: M. F., Ismail, Wan Azmi, Wan Hamzah
Formato: Conference or Workshop Item
Idioma:English
English
Publicado em: Springer Singapore 2023
Assuntos:
Acesso em linha:http://umpir.ump.edu.my/id/eprint/41843/1/Performance%20Investigation%20of%20R32%20and%20R410a%20Refrigerants%20with%20Different%20Compressor.pdf
http://umpir.ump.edu.my/id/eprint/41843/2/Performance%20Investigation%20of%20R32%20and%20R410a%20Refrigerants%20with%20Different%20Compressor%20Lubricants.pdf

Registros relacionados