A study of performance analysis of fan coil unit system for FKM's air conditioner

Air conditioning system is a process of ventilation, air movement, air cleanliness, dehumidifying and cooling in order to give comfort to occupant. In tropical climate countries like Malaysia, air conditioner is very important to cool building space. Currently, most of commercial building in Malaysi...

Full description

Bibliographic Details
Main Author: Nina Nadia, Sahim
Format: Undergraduates Project Papers
Language:English
Published: 2012
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/4507/1/33.PERFORMANCE%20ANALYSIS%20OF%20FAN%20COIL%20UNIT%20SYSTEM%20FOR%20FKM%E2%80%99S%20AIR%20CONDITIONER.pdf
_version_ 1796989817532186624
author Nina Nadia, Sahim
author_facet Nina Nadia, Sahim
author_sort Nina Nadia, Sahim
collection UMP
description Air conditioning system is a process of ventilation, air movement, air cleanliness, dehumidifying and cooling in order to give comfort to occupant. In tropical climate countries like Malaysia, air conditioner is very important to cool building space. Currently, most of commercial building in Malaysia is equipped with air conditioner either by using split unit or central unit types. Installation of air conditioner requires heat gain estimation, so that the capacity of the installed air conditioner is suitable for the particular area and gives the best performance in its operation. This project is carried out to determine the heat gain and analyze performance of air conditioner at second floor Block 2. FKM buildings start the operation in 2009. In 2009, every building in FKM building is window glass single glazing without tinted film. Started from year 2011, those windows glass have been tinted to reduce glare and heat gain inside the room. Besides that, factor of recommended setting temperature by Malaysia government at 24 °C also affected the design of air conditioning system. Generally, the main air conditioning system working at FKM is central air conditioning system. A method has been implemented to obtain the heat gain which is cooling load temperature difference/cooling load factor, (CLTD/CLF) while for cooling capacity, energy equation throughout fan coil has been used. The heat gain study have been considered five rooms in the second floor Block 2 (lecture rooms) which are Lecture Room 5 (BK 5), Lecture Room 6 (BK 6), Briefing Room 8 (BT 8), Briefing Room 6 and 7 (BT 6 and 7), and Discussion Room 6, 7 and 8 (BP 6, 7 and 8). From these five rooms, there are only two rooms have been analyze the performance which are Bilik Kuliah 5 and Bilik Taklimat 8. The study of heat gain is conducted from 8.00 am until 5.00 pm. The result shows that the heat gains are 14.43 kW, 14.31 kW, 8.35 kW, 15.61 kW and 7.3 kW, respectively. The percentage comparison heat gain against cooling coil load with load for Briefing Room 8 and Lecture Room 5 are 34.45 % and 47.98 % less than the heat gain by rooms. It happened because the data for cooling coil load were taken at steady state condition, while the heat gain data were measured in unsteady state condition. Thus, the fan coil still capable to cooled the rooms in steady state conditions.
first_indexed 2024-03-06T11:42:41Z
format Undergraduates Project Papers
id UMPir4507
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T11:42:41Z
publishDate 2012
record_format dspace
spelling UMPir45072023-03-09T03:53:48Z http://umpir.ump.edu.my/id/eprint/4507/ A study of performance analysis of fan coil unit system for FKM's air conditioner Nina Nadia, Sahim TH Building construction Air conditioning system is a process of ventilation, air movement, air cleanliness, dehumidifying and cooling in order to give comfort to occupant. In tropical climate countries like Malaysia, air conditioner is very important to cool building space. Currently, most of commercial building in Malaysia is equipped with air conditioner either by using split unit or central unit types. Installation of air conditioner requires heat gain estimation, so that the capacity of the installed air conditioner is suitable for the particular area and gives the best performance in its operation. This project is carried out to determine the heat gain and analyze performance of air conditioner at second floor Block 2. FKM buildings start the operation in 2009. In 2009, every building in FKM building is window glass single glazing without tinted film. Started from year 2011, those windows glass have been tinted to reduce glare and heat gain inside the room. Besides that, factor of recommended setting temperature by Malaysia government at 24 °C also affected the design of air conditioning system. Generally, the main air conditioning system working at FKM is central air conditioning system. A method has been implemented to obtain the heat gain which is cooling load temperature difference/cooling load factor, (CLTD/CLF) while for cooling capacity, energy equation throughout fan coil has been used. The heat gain study have been considered five rooms in the second floor Block 2 (lecture rooms) which are Lecture Room 5 (BK 5), Lecture Room 6 (BK 6), Briefing Room 8 (BT 8), Briefing Room 6 and 7 (BT 6 and 7), and Discussion Room 6, 7 and 8 (BP 6, 7 and 8). From these five rooms, there are only two rooms have been analyze the performance which are Bilik Kuliah 5 and Bilik Taklimat 8. The study of heat gain is conducted from 8.00 am until 5.00 pm. The result shows that the heat gains are 14.43 kW, 14.31 kW, 8.35 kW, 15.61 kW and 7.3 kW, respectively. The percentage comparison heat gain against cooling coil load with load for Briefing Room 8 and Lecture Room 5 are 34.45 % and 47.98 % less than the heat gain by rooms. It happened because the data for cooling coil load were taken at steady state condition, while the heat gain data were measured in unsteady state condition. Thus, the fan coil still capable to cooled the rooms in steady state conditions. 2012-06 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/4507/1/33.PERFORMANCE%20ANALYSIS%20OF%20FAN%20COIL%20UNIT%20SYSTEM%20FOR%20FKM%E2%80%99S%20AIR%20CONDITIONER.pdf Nina Nadia, Sahim (2012) A study of performance analysis of fan coil unit system for FKM's air conditioner. Faculty of Mechanical Engineering, Universiti Malaysia Pahang.
spellingShingle TH Building construction
Nina Nadia, Sahim
A study of performance analysis of fan coil unit system for FKM's air conditioner
title A study of performance analysis of fan coil unit system for FKM's air conditioner
title_full A study of performance analysis of fan coil unit system for FKM's air conditioner
title_fullStr A study of performance analysis of fan coil unit system for FKM's air conditioner
title_full_unstemmed A study of performance analysis of fan coil unit system for FKM's air conditioner
title_short A study of performance analysis of fan coil unit system for FKM's air conditioner
title_sort study of performance analysis of fan coil unit system for fkm s air conditioner
topic TH Building construction
url http://umpir.ump.edu.my/id/eprint/4507/1/33.PERFORMANCE%20ANALYSIS%20OF%20FAN%20COIL%20UNIT%20SYSTEM%20FOR%20FKM%E2%80%99S%20AIR%20CONDITIONER.pdf
work_keys_str_mv AT ninanadiasahim astudyofperformanceanalysisoffancoilunitsystemforfkmsairconditioner
AT ninanadiasahim studyofperformanceanalysisoffancoilunitsystemforfkmsairconditioner