Wind load effect to the ratio cover structure

Structural damage due to wind storm is often occurred in Malaysia. Base on previous study conducted, non-engineering Structures are simply to fail due to wind load. One of the common non-engineering structures is patio or always be identify as awning. This type of structure is commonly used as addit...

Full description

Bibliographic Details
Main Author: Mohd Erie Adnin, Zamri
Format: Undergraduates Project Papers
Language:English
Published: 2014
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/9371/1/MOHD%20ERIE%20ADNIN%20BIN%20ZAMRI.PDF
_version_ 1825822266609369088
author Mohd Erie Adnin, Zamri
author_facet Mohd Erie Adnin, Zamri
author_sort Mohd Erie Adnin, Zamri
collection UMP
description Structural damage due to wind storm is often occurred in Malaysia. Base on previous study conducted, non-engineering Structures are simply to fail due to wind load. One of the common non-engineering structures is patio or always be identify as awning. This type of structure is commonly used as additional extension to Malaysian building system for several purposes. The information related to this type of structure due to wind load is very rare. Therefore, further understanding of the wind load impact to patio need to be well understood before structural can be design to resist wind load. Therefore this study is conducted to identify the possibility of wind speed can caused the failure to the structure. Three type of dimension are used in this study which is 3m x 3m, 3m x 4.2m and 3m x 5,4m which are been identified as common size than widely used in Malaysia. Structural Design Software namely SAP 2000 are been used to examine the wind load effect to patio. From the result is shown that by minimum wind speed that cause possibility of failure to the patio structures is 16 m/s. Result also had shown that the distance between the trusses systems in patio structure need to be considered. Therefore the consideration of wind load design in patio structure need to be concern during construction stage. Further investigation need to be investigated in order to ensure the patio can able to withstand to wind load.
first_indexed 2024-03-06T11:54:01Z
format Undergraduates Project Papers
id UMPir9371
institution Universiti Malaysia Pahang
language English
last_indexed 2024-03-06T11:54:01Z
publishDate 2014
record_format dspace
spelling UMPir93712021-07-21T03:10:34Z http://umpir.ump.edu.my/id/eprint/9371/ Wind load effect to the ratio cover structure Mohd Erie Adnin, Zamri TJ Mechanical engineering and machinery Structural damage due to wind storm is often occurred in Malaysia. Base on previous study conducted, non-engineering Structures are simply to fail due to wind load. One of the common non-engineering structures is patio or always be identify as awning. This type of structure is commonly used as additional extension to Malaysian building system for several purposes. The information related to this type of structure due to wind load is very rare. Therefore, further understanding of the wind load impact to patio need to be well understood before structural can be design to resist wind load. Therefore this study is conducted to identify the possibility of wind speed can caused the failure to the structure. Three type of dimension are used in this study which is 3m x 3m, 3m x 4.2m and 3m x 5,4m which are been identified as common size than widely used in Malaysia. Structural Design Software namely SAP 2000 are been used to examine the wind load effect to patio. From the result is shown that by minimum wind speed that cause possibility of failure to the patio structures is 16 m/s. Result also had shown that the distance between the trusses systems in patio structure need to be considered. Therefore the consideration of wind load design in patio structure need to be concern during construction stage. Further investigation need to be investigated in order to ensure the patio can able to withstand to wind load. 2014-07 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/9371/1/MOHD%20ERIE%20ADNIN%20BIN%20ZAMRI.PDF Mohd Erie Adnin, Zamri (2014) Wind load effect to the ratio cover structure. Faculty of Civil Engineering & Earth Resources, Universiti Malaysia Pahang.
spellingShingle TJ Mechanical engineering and machinery
Mohd Erie Adnin, Zamri
Wind load effect to the ratio cover structure
title Wind load effect to the ratio cover structure
title_full Wind load effect to the ratio cover structure
title_fullStr Wind load effect to the ratio cover structure
title_full_unstemmed Wind load effect to the ratio cover structure
title_short Wind load effect to the ratio cover structure
title_sort wind load effect to the ratio cover structure
topic TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/9371/1/MOHD%20ERIE%20ADNIN%20BIN%20ZAMRI.PDF
work_keys_str_mv AT mohderieadninzamri windloadeffecttotheratiocoverstructure