Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment

A prerequisite for ensuring the quality of medicines is their production in accordance with the rules of GMP (Good Manufacturing Practice for Medicinal Products), one of the most important requirements of which is equipment cleaning. In many cases, the same equipment is used in the production of var...

Full description

Bibliographic Details
Main Authors: O. D. Voitiuk, A. V. Yegorova, Yu. V. Scrypynets, S. N. Kashutskуy, V. P. Antonovich
Format: Article
Language:Ukrainian
Published: The State Expert Center of the Ministry of Health of Ukraine 2019-09-01
Series:Фармацевтичний журнал
Subjects:
Online Access:https://pharmj.org.ua/index.php/journal/article/view/620/583
_version_ 1818336881904975872
author O. D. Voitiuk
A. V. Yegorova
Yu. V. Scrypynets
S. N. Kashutskуy
V. P. Antonovich
author_facet O. D. Voitiuk
A. V. Yegorova
Yu. V. Scrypynets
S. N. Kashutskуy
V. P. Antonovich
author_sort O. D. Voitiuk
collection DOAJ
description A prerequisite for ensuring the quality of medicines is their production in accordance with the rules of GMP (Good Manufacturing Practice for Medicinal Products), one of the most important requirements of which is equipment cleaning. In many cases, the same equipment is used in the production of various preparations. Therefore, to prevent contamination of each of the following drugs, the previous one, it is very important to carry out an effective equipment cleaning procedure with a mandatory assessment of its purity. The purpose of this study was to develop simple, express, selective methods for luminescent determination of residual quantities of APIs of trazodone hydrochloride (TG) and melatonin (MT) in washes to control the completeness of their removal when cleaning process equipment. The excitation and luminescence spectra were recorded using a Cary Eclipse "Varian" spectrofluorimeter (Australia) with a xenon lamp 150 W. Electronic absorption spectra were recorded on a UV-2401 PC spectrophotometer «Shimadzu» (Japan). The electronic absorption spectra of TG and MT have absorption bands in the UV spectral region. It was established experimentally that the excitation spectra of TG and MT are similar to their absorption spectra (λex = 318 nm (TG) and λem = 274 nm (MT)). The effect on the luminescence intensity of TG and MT of methanol, ethanol, acetonitrile, dimethylformamide, dimethylsulfoxide, propanol (50 v/v) was studied. It is established that the maximum luminescence is observed in water. The methods were validated according to the following parameters: specificity, linearity, accuracy, limit of quantitation. The degree of extraction of trazodone hydrochloride and melatonin from applicators and surfaces of pharmaceutical equipment is more than 90%. The developed methods can be recommended for determining the residual amounts of trazodone hydrochloride and melatonin while monitoring the quality of the cleaning of pharmaceutical equipment.
first_indexed 2024-12-13T14:46:22Z
format Article
id doaj.art-0032d1e821a1493688597f77ab8fb249
institution Directory Open Access Journal
issn 0367-3057
2617-9628
language Ukrainian
last_indexed 2024-12-13T14:46:22Z
publishDate 2019-09-01
publisher The State Expert Center of the Ministry of Health of Ukraine
record_format Article
series Фармацевтичний журнал
spelling doaj.art-0032d1e821a1493688597f77ab8fb2492022-12-21T23:41:27ZukrThe State Expert Center of the Ministry of Health of UkraineФармацевтичний журнал0367-30572617-96282019-09-0144738110.32352/0367-3057.4.19.08Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipmentO. D. Voitiuk0A. V. Yegorova1Yu. V. Scrypynets2S. N. Kashutskуy3V. P. Antonovich4«INTERCHEM SLC», OdesaBogatsky Physico-chemical Institute of the National Academy of Sciences of Ukraine, OdesaBogatsky Physico-chemical Institute of the National Academy of Sciences of Ukraine, Odesa«INTERCHEM SLC», OdesaBogatsky Physico-chemical Institute of the National Academy of Sciences of Ukraine, OdesaA prerequisite for ensuring the quality of medicines is their production in accordance with the rules of GMP (Good Manufacturing Practice for Medicinal Products), one of the most important requirements of which is equipment cleaning. In many cases, the same equipment is used in the production of various preparations. Therefore, to prevent contamination of each of the following drugs, the previous one, it is very important to carry out an effective equipment cleaning procedure with a mandatory assessment of its purity. The purpose of this study was to develop simple, express, selective methods for luminescent determination of residual quantities of APIs of trazodone hydrochloride (TG) and melatonin (MT) in washes to control the completeness of their removal when cleaning process equipment. The excitation and luminescence spectra were recorded using a Cary Eclipse "Varian" spectrofluorimeter (Australia) with a xenon lamp 150 W. Electronic absorption spectra were recorded on a UV-2401 PC spectrophotometer «Shimadzu» (Japan). The electronic absorption spectra of TG and MT have absorption bands in the UV spectral region. It was established experimentally that the excitation spectra of TG and MT are similar to their absorption spectra (λex = 318 nm (TG) and λem = 274 nm (MT)). The effect on the luminescence intensity of TG and MT of methanol, ethanol, acetonitrile, dimethylformamide, dimethylsulfoxide, propanol (50 v/v) was studied. It is established that the maximum luminescence is observed in water. The methods were validated according to the following parameters: specificity, linearity, accuracy, limit of quantitation. The degree of extraction of trazodone hydrochloride and melatonin from applicators and surfaces of pharmaceutical equipment is more than 90%. The developed methods can be recommended for determining the residual amounts of trazodone hydrochloride and melatonin while monitoring the quality of the cleaning of pharmaceutical equipment.https://pharmj.org.ua/index.php/journal/article/view/620/583luminescencetrazodone hydrochloridemelatonincleaning of pharmaceutical equipment
spellingShingle O. D. Voitiuk
A. V. Yegorova
Yu. V. Scrypynets
S. N. Kashutskуy
V. P. Antonovich
Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
Фармацевтичний журнал
luminescence
trazodone hydrochloride
melatonin
cleaning of pharmaceutical equipment
title Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
title_full Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
title_fullStr Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
title_full_unstemmed Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
title_short Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
title_sort luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
topic luminescence
trazodone hydrochloride
melatonin
cleaning of pharmaceutical equipment
url https://pharmj.org.ua/index.php/journal/article/view/620/583
work_keys_str_mv AT odvoitiuk luminescentdeterminationofresiduesoftrazodonhydrochlorideandmelatoninaftercleaningpharmaceuticalequipment
AT avyegorova luminescentdeterminationofresiduesoftrazodonhydrochlorideandmelatoninaftercleaningpharmaceuticalequipment
AT yuvscrypynets luminescentdeterminationofresiduesoftrazodonhydrochlorideandmelatoninaftercleaningpharmaceuticalequipment
AT snkashutskuy luminescentdeterminationofresiduesoftrazodonhydrochlorideandmelatoninaftercleaningpharmaceuticalequipment
AT vpantonovich luminescentdeterminationofresiduesoftrazodonhydrochlorideandmelatoninaftercleaningpharmaceuticalequipment