Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment
Stray current is a relevant phenomenon in particular for DC electrified transportation systems, affecting track and infrastructure within the right of way and other structures and installations nearby. It worsens with time and the level of protection depends on timely maintenance, as well as correct...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-06-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/23/13/5900 |
_version_ | 1797590826264559616 |
---|---|
author | Sahil Bhagat Jacopo Bongiorno Andrea Mariscotti |
author_facet | Sahil Bhagat Jacopo Bongiorno Andrea Mariscotti |
author_sort | Sahil Bhagat |
collection | DOAJ |
description | Stray current is a relevant phenomenon in particular for DC electrified transportation systems, affecting track and infrastructure within the right of way and other structures and installations nearby. It worsens with time and the level of protection depends on timely maintenance, as well as correct design choices. The assessment of track insulation is the starting point for both stray current monitoring systems and at commissioning or upon major changes. Standardized methods (ref. EN 50122-2 or IEC 62128-2) have been almost unchanged in the last 20 years but suffer from accuracy issues and variability due to parameters and conditions not under the operator’s control. The uncertainty of test methods is increasingly important now that contractual specifications require a high level of insulation for new systems. A critical discussion and analysis of the sources of variability and practical constraints is proposed, followed by an evaluation of uncertainty, with the objective not only to assess the accuracy of the provided results, but also to foster research on innovative, more flexible and accurate methods. |
first_indexed | 2024-03-11T01:28:58Z |
format | Article |
id | doaj.art-004a11101508471c8efe25b21d8f504e |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-03-11T01:28:58Z |
publishDate | 2023-06-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-004a11101508471c8efe25b21d8f504e2023-11-18T17:28:27ZengMDPI AGSensors1424-82202023-06-012313590010.3390/s23135900Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current AssessmentSahil Bhagat0Jacopo Bongiorno1Andrea Mariscotti2DITEN, University of Genova, 16145 Genova, ItalyRINA Services S.p.A., 16138 Genoa, ItalyDITEN, University of Genova, 16145 Genova, ItalyStray current is a relevant phenomenon in particular for DC electrified transportation systems, affecting track and infrastructure within the right of way and other structures and installations nearby. It worsens with time and the level of protection depends on timely maintenance, as well as correct design choices. The assessment of track insulation is the starting point for both stray current monitoring systems and at commissioning or upon major changes. Standardized methods (ref. EN 50122-2 or IEC 62128-2) have been almost unchanged in the last 20 years but suffer from accuracy issues and variability due to parameters and conditions not under the operator’s control. The uncertainty of test methods is increasingly important now that contractual specifications require a high level of insulation for new systems. A critical discussion and analysis of the sources of variability and practical constraints is proposed, followed by an evaluation of uncertainty, with the objective not only to assess the accuracy of the provided results, but also to foster research on innovative, more flexible and accurate methods.https://www.mdpi.com/1424-8220/23/13/5900DC power systemsguideway electric transportation systemsstray currenttest methodsuncertainty |
spellingShingle | Sahil Bhagat Jacopo Bongiorno Andrea Mariscotti Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment Sensors DC power systems guideway electric transportation systems stray current test methods uncertainty |
title | Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment |
title_full | Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment |
title_fullStr | Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment |
title_full_unstemmed | Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment |
title_short | Uncertainty of Standardized Track Insulation Measurement Methods for Stray Current Assessment |
title_sort | uncertainty of standardized track insulation measurement methods for stray current assessment |
topic | DC power systems guideway electric transportation systems stray current test methods uncertainty |
url | https://www.mdpi.com/1424-8220/23/13/5900 |
work_keys_str_mv | AT sahilbhagat uncertaintyofstandardizedtrackinsulationmeasurementmethodsforstraycurrentassessment AT jacopobongiorno uncertaintyofstandardizedtrackinsulationmeasurementmethodsforstraycurrentassessment AT andreamariscotti uncertaintyofstandardizedtrackinsulationmeasurementmethodsforstraycurrentassessment |