Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral Instability
Abstract Objectives The aim of the present study was to describe the dimensions of the coracoid grafts in our Latarjet surgeries and compare them with the results described in the literature. In addition, the feasibility of the 7-millimeter rule was verified. Methods Individuals with anterior glen...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Thieme Revinter Publicações Ltda.
|
Series: | Revista Brasileira de Ortopedia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000200215&lng=en&tlng=en |
_version_ | 1827266659854843904 |
---|---|
author | Bernardo V.P. Alves Gabriel S. Silva Fábio Y. Matsumoto Marco T. Ferreira Almiro G. Britto Fernando C. Mothes |
author_facet | Bernardo V.P. Alves Gabriel S. Silva Fábio Y. Matsumoto Marco T. Ferreira Almiro G. Britto Fernando C. Mothes |
author_sort | Bernardo V.P. Alves |
collection | DOAJ |
description | Abstract Objectives The aim of the present study was to describe the dimensions of the coracoid grafts in our Latarjet surgeries and compare them with the results described in the literature. In addition, the feasibility of the 7-millimeter rule was verified. Methods Individuals with anterior glenohumeral instability with or without bone loss participated in the present study. The dimensions of 31 coracoid process grafts of patients who were submitted to the Latarjet surgical technique were measured with an analogical caliper and recorded for posterior analysis. Results The dimensions of the coracoid graft did not show statistically significant differences related to gender. The graft width obtained from our sample presented similarities with the dimensions reported in the literature. However, the length and thickness were smaller when compared to the reference study (Young et al, 2013).15 The 7-millimeter rule was considered feasible regarding the graft dimensions obtained from our sample. Conclusion The coracoid graft dimensions were similar to the dimensions described in the literature regarding width, but the same was not found for length and thickness; and the 7-millimeter rule was feasible regarding the graft dimensions obtained from our sample. |
first_indexed | 2024-03-08T07:30:44Z |
format | Article |
id | doaj.art-0067c7d6befa44b5bec24bfe71eeaae6 |
institution | Directory Open Access Journal |
issn | 0102-3616 1982-4378 |
language | English |
last_indexed | 2025-03-22T04:21:22Z |
publisher | Thieme Revinter Publicações Ltda. |
record_format | Article |
series | Revista Brasileira de Ortopedia |
spelling | doaj.art-0067c7d6befa44b5bec24bfe71eeaae62024-04-28T07:43:48ZengThieme Revinter Publicações Ltda.Revista Brasileira de Ortopedia0102-36161982-437855221522010.1055/s-0039-1698801S0102-36162020000200215Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral InstabilityBernardo V.P. AlvesGabriel S. SilvaFábio Y. MatsumotoMarco T. FerreiraAlmiro G. BrittoFernando C. MothesAbstract Objectives The aim of the present study was to describe the dimensions of the coracoid grafts in our Latarjet surgeries and compare them with the results described in the literature. In addition, the feasibility of the 7-millimeter rule was verified. Methods Individuals with anterior glenohumeral instability with or without bone loss participated in the present study. The dimensions of 31 coracoid process grafts of patients who were submitted to the Latarjet surgical technique were measured with an analogical caliper and recorded for posterior analysis. Results The dimensions of the coracoid graft did not show statistically significant differences related to gender. The graft width obtained from our sample presented similarities with the dimensions reported in the literature. However, the length and thickness were smaller when compared to the reference study (Young et al, 2013).15 The 7-millimeter rule was considered feasible regarding the graft dimensions obtained from our sample. Conclusion The coracoid graft dimensions were similar to the dimensions described in the literature regarding width, but the same was not found for length and thickness; and the 7-millimeter rule was feasible regarding the graft dimensions obtained from our sample.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000200215&lng=en&tlng=enluxação do ombroarticulação do ombro/lesõesinstabilidade articularcavidade glenoidetransplante ósseo |
spellingShingle | Bernardo V.P. Alves Gabriel S. Silva Fábio Y. Matsumoto Marco T. Ferreira Almiro G. Britto Fernando C. Mothes Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral Instability Revista Brasileira de Ortopedia luxação do ombro articulação do ombro/lesões instabilidade articular cavidade glenoide transplante ósseo |
title | Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral Instability |
title_full | Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral Instability |
title_fullStr | Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral Instability |
title_full_unstemmed | Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral Instability |
title_short | Comparative Evaluation of Coracoid Graft Dimensions in the Latarjet Surgery for Anterior Glenohumeral Instability |
title_sort | comparative evaluation of coracoid graft dimensions in the latarjet surgery for anterior glenohumeral instability |
topic | luxação do ombro articulação do ombro/lesões instabilidade articular cavidade glenoide transplante ósseo |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162020000200215&lng=en&tlng=en |
work_keys_str_mv | AT bernardovpalves comparativeevaluationofcoracoidgraftdimensionsinthelatarjetsurgeryforanteriorglenohumeralinstability AT gabrielssilva comparativeevaluationofcoracoidgraftdimensionsinthelatarjetsurgeryforanteriorglenohumeralinstability AT fabioymatsumoto comparativeevaluationofcoracoidgraftdimensionsinthelatarjetsurgeryforanteriorglenohumeralinstability AT marcotferreira comparativeevaluationofcoracoidgraftdimensionsinthelatarjetsurgeryforanteriorglenohumeralinstability AT almirogbritto comparativeevaluationofcoracoidgraftdimensionsinthelatarjetsurgeryforanteriorglenohumeralinstability AT fernandocmothes comparativeevaluationofcoracoidgraftdimensionsinthelatarjetsurgeryforanteriorglenohumeralinstability |