Optimization of the control loops of the variable frequency induction motor drive of the flame reactor feed screw
In the paper the optimization of the control loops of the variable frequency induction motor drive for the feed screw of a flame reactor has been carried out to obtain required dynamic characteristics of the electric drive for known parameters of the plant. Simulation studies of basic control loops...
Main Authors: | Yu.N. Dementyev, I. Vajda, N.V. Koyain, K.N. Negodin, K.V. Obraztsov |
---|---|
Format: | Article |
Language: | English |
Published: |
European Alliance for Innovation (EAI)
2017-07-01
|
Series: | EAI Endorsed Transactions on Energy Web |
Subjects: | |
Online Access: | http://eudl.eu/doi/10.4108/eai.11-7-2017.152765 |