Improvement in the microhardness and corrosion behaviour of Ti-14Mn biomedical alloy by cold working
β -titanium alloys are essential in many applications, particularly biomedical applications. Ti-14Mn β -type alloy was produced using an electric arc furnace from raw alloying elements in an inert atmosphere. The alloy was homogenized at 1000 °C for 8 h to ensure the complete composition distributio...
Main Authors: | M K Gouda, Salah A Salman, Saad Ebied |
---|---|
Format: | Article |
Language: | English |
Published: |
IOP Publishing
2022-01-01
|
Series: | Materials Research Express |
Subjects: | |
Online Access: | https://doi.org/10.1088/2053-1591/ac4b77 |
Similar Items
-
Effect of Thermal Treatment of Biomedical Ti-6Al-4V Alloy on Corrosion Resistance in Simulated Physiological Solutions
by: J. Ryba, et al.
Published: (2020-03-01) -
Corrosion Resistance After Mechanical Deformation of the Ti30Ta Experimental Alloy for Using in Biomedical Applications
by: Kerolene Barboza da Silva, et al.
Published: (2017-08-01) -
Corrosion Behavior of Ti-6Al-4V Alloy in Different Media
by: Slafa I. Ibrahim, et al.
Published: (2010-01-01) -
Ti–15Zr and Ti–15Zr–5Mo Biomaterials Alloys: An Analysis of Corrosion and Tribocorrosion Behavior in Phosphate-Buffered Saline Solution
by: Adriana Alencar Santos, et al.
Published: (2023-02-01) -
Review on Corrosion, Tribocorrosion and Osseointegration of Titanium Alloys as Biomaterials
by: Jamal Takadoum
Published: (2023-11-01)