Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report

<p>Abstract</p> <p>Introduction</p> <p>High frequency percussive ventilation is a ventilatory technique that delivers small bursts of high flow respiratory gas into the lungs at high rates. It is classified as a pneumatically powered, pressure-regulated, time-cycled, hi...

Full description

Bibliographic Details
Main Authors: Persi Bruno, Zanatta Paolo, Salandin Valeria, Forti Alessandro, Sorbara Carlo
Format: Article
Language:English
Published: BMC 2010-10-01
Series:Journal of Medical Case Reports
Online Access:http://www.jmedicalcasereports.com/content/4/1/339
_version_ 1811247987304693760
author Persi Bruno
Zanatta Paolo
Salandin Valeria
Forti Alessandro
Sorbara Carlo
author_facet Persi Bruno
Zanatta Paolo
Salandin Valeria
Forti Alessandro
Sorbara Carlo
author_sort Persi Bruno
collection DOAJ
description <p>Abstract</p> <p>Introduction</p> <p>High frequency percussive ventilation is a ventilatory technique that delivers small bursts of high flow respiratory gas into the lungs at high rates. It is classified as a pneumatically powered, pressure-regulated, time-cycled, high-frequency flow interrupter modality of ventilation. High frequency percussive ventilation improves the arterial partial pressure of oxygen with the same positive end expiratory pressure and fractional inspiratory oxygen level as conventional ventilation using a minor mean airway pressure in an open circuit. It reduces the barotraumatic events in a hypoxic patient who has low lung-compliance. To the best of our knowledge, there have been no papers published about this ventilation modality in patients with severe hypoxaemia after cardiac surgery.</p> <p>Case presentation</p> <p>A 75-year-old Caucasian man with an ejection fraction of 27 percent, developed a lung infection with severe hypoxaemia [partial pressure of oxygen/fractional inspiratory oxygen of 90] ten days after cardiac surgery. Conventional ventilation did not improve the gas exchange. He was treated with high frequency percussive ventilation for 12 hours with a low conventional respiratory rate (five per minute). His cardiac output and systemic and pulmonary pressures were monitored.</p> <p>Compared to conventional ventilation, high frequency percussive ventilation gives an improvement of the partial pressure of oxygen from 90 to 190 mmHg with the same fractional inspiratory oxygen and positive end expiratory pressure level. His right ventricular stroke work index was lowered from 19 to seven g-m/m<sup>2</sup>/beat; his pulmonary vascular resistance index from 267 to 190 dynes•seconds/cm<sup>5</sup>/m<sup>2</sup>; left ventricular stroke work index from 28 to 16 gm-m/m<sup>2</sup>/beat; and his pulmonary arterial wedge pressure was lowered from 32 to 24 mmHg with a lower mean airway pressure compared to conventional ventilation. His cardiac index (2.7 L/min/m<sup>2</sup>) and ejection fraction (27 percent) did not change.</p> <p>Conclusion</p> <p>Although the high frequency percussive ventilation was started ten days after the conventional ventilation, it still improved the gas exchange. The reduction of right ventricular stroke work index, left ventricular stroke work index, pulmonary vascular resistance index and pulmonary arterial wedge pressure is directly related to the lower respiratory mean airway pressure and the consequent afterload reduction.</p>
first_indexed 2024-04-12T15:20:11Z
format Article
id doaj.art-008ebb0d1b06433bbc079e04940a23ac
institution Directory Open Access Journal
issn 1752-1947
language English
last_indexed 2024-04-12T15:20:11Z
publishDate 2010-10-01
publisher BMC
record_format Article
series Journal of Medical Case Reports
spelling doaj.art-008ebb0d1b06433bbc079e04940a23ac2022-12-22T03:27:29ZengBMCJournal of Medical Case Reports1752-19472010-10-014133910.1186/1752-1947-4-339Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case reportPersi BrunoZanatta PaoloSalandin ValeriaForti AlessandroSorbara Carlo<p>Abstract</p> <p>Introduction</p> <p>High frequency percussive ventilation is a ventilatory technique that delivers small bursts of high flow respiratory gas into the lungs at high rates. It is classified as a pneumatically powered, pressure-regulated, time-cycled, high-frequency flow interrupter modality of ventilation. High frequency percussive ventilation improves the arterial partial pressure of oxygen with the same positive end expiratory pressure and fractional inspiratory oxygen level as conventional ventilation using a minor mean airway pressure in an open circuit. It reduces the barotraumatic events in a hypoxic patient who has low lung-compliance. To the best of our knowledge, there have been no papers published about this ventilation modality in patients with severe hypoxaemia after cardiac surgery.</p> <p>Case presentation</p> <p>A 75-year-old Caucasian man with an ejection fraction of 27 percent, developed a lung infection with severe hypoxaemia [partial pressure of oxygen/fractional inspiratory oxygen of 90] ten days after cardiac surgery. Conventional ventilation did not improve the gas exchange. He was treated with high frequency percussive ventilation for 12 hours with a low conventional respiratory rate (five per minute). His cardiac output and systemic and pulmonary pressures were monitored.</p> <p>Compared to conventional ventilation, high frequency percussive ventilation gives an improvement of the partial pressure of oxygen from 90 to 190 mmHg with the same fractional inspiratory oxygen and positive end expiratory pressure level. His right ventricular stroke work index was lowered from 19 to seven g-m/m<sup>2</sup>/beat; his pulmonary vascular resistance index from 267 to 190 dynes•seconds/cm<sup>5</sup>/m<sup>2</sup>; left ventricular stroke work index from 28 to 16 gm-m/m<sup>2</sup>/beat; and his pulmonary arterial wedge pressure was lowered from 32 to 24 mmHg with a lower mean airway pressure compared to conventional ventilation. His cardiac index (2.7 L/min/m<sup>2</sup>) and ejection fraction (27 percent) did not change.</p> <p>Conclusion</p> <p>Although the high frequency percussive ventilation was started ten days after the conventional ventilation, it still improved the gas exchange. The reduction of right ventricular stroke work index, left ventricular stroke work index, pulmonary vascular resistance index and pulmonary arterial wedge pressure is directly related to the lower respiratory mean airway pressure and the consequent afterload reduction.</p>http://www.jmedicalcasereports.com/content/4/1/339
spellingShingle Persi Bruno
Zanatta Paolo
Salandin Valeria
Forti Alessandro
Sorbara Carlo
Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report
Journal of Medical Case Reports
title Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report
title_full Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report
title_fullStr Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report
title_full_unstemmed Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report
title_short Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report
title_sort haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery a case report
url http://www.jmedicalcasereports.com/content/4/1/339
work_keys_str_mv AT persibruno haemodynamicsandoxygenationimprovementinducedbyhighfrequencypercussiveventilationinapatientwithhypoxiafollowingcardiacsurgeryacasereport
AT zanattapaolo haemodynamicsandoxygenationimprovementinducedbyhighfrequencypercussiveventilationinapatientwithhypoxiafollowingcardiacsurgeryacasereport
AT salandinvaleria haemodynamicsandoxygenationimprovementinducedbyhighfrequencypercussiveventilationinapatientwithhypoxiafollowingcardiacsurgeryacasereport
AT fortialessandro haemodynamicsandoxygenationimprovementinducedbyhighfrequencypercussiveventilationinapatientwithhypoxiafollowingcardiacsurgeryacasereport
AT sorbaracarlo haemodynamicsandoxygenationimprovementinducedbyhighfrequencypercussiveventilationinapatientwithhypoxiafollowingcardiacsurgeryacasereport