<b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254

The present study determined the neuromuscular fatigue threshold (NFT) using four different time-periods of analysis of the electromyographic signal and compared these estimations with critical power (CP). Fifteen healthy young men (73.6 ± 5.1 kg, 177.8 ± 7.0 cm, 23.4 ± 5.2 years) performed 3-4 diff...

Full description

Bibliographic Details
Main Authors: Alexandre Hideki Okano, Antonio Carlos de Moraes, Bruno de Paula Smirmaul, Ricardo Okada Triana, Ezequiel Moreira Gonçalves, Leandro Ricardo Altimari, Eduardo Bodnariuc Fontes
Format: Article
Language:English
Published: Universidade Federal de Santa Catarina 2012-05-01
Series:Revista Brasileira de Cineantropometria e Desempenho Humano
Subjects:
Online Access:http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/21877/21730
_version_ 1819074235172126720
author Alexandre Hideki Okano
Antonio Carlos de Moraes
Bruno de Paula Smirmaul
Ricardo Okada Triana
Ezequiel Moreira Gonçalves
Leandro Ricardo Altimari
Eduardo Bodnariuc Fontes
author_facet Alexandre Hideki Okano
Antonio Carlos de Moraes
Bruno de Paula Smirmaul
Ricardo Okada Triana
Ezequiel Moreira Gonçalves
Leandro Ricardo Altimari
Eduardo Bodnariuc Fontes
author_sort Alexandre Hideki Okano
collection DOAJ
description The present study determined the neuromuscular fatigue threshold (NFT) using four different time-periods of analysis of the electromyographic signal and compared these estimations with critical power (CP). Fifteen healthy young men (73.6 ± 5.1 kg, 177.8 ± 7.0 cm, 23.4 ± 5.2 years) performed 3-4 different severe constant workload trials until exhaustion on a cycle ergometer with simultaneous SEMG signals acquisition. The obtained data permitted NFT estimation with four different periods of analysis as follows: initial 30s (T30), 1min (T1), 2min (T2) and total time (TT), as well as CP. T30 and T1 were significantly higher than TT and CP and, T2 and TT did not differ between each other, and both were significantly higher than CP. In addition, TT was significantly correlated to CP (0.72; P < 0.05) and to T2 (0.58; P < 0.05). We conclude that NFT overestimates CP, independent of the time-period analysis used for its determination.
first_indexed 2024-12-21T18:06:17Z
format Article
id doaj.art-00fc4fe20f984663bc1e2f1212ff31be
institution Directory Open Access Journal
issn 1415-8426
1980-0037
language English
last_indexed 2024-12-21T18:06:17Z
publishDate 2012-05-01
publisher Universidade Federal de Santa Catarina
record_format Article
series Revista Brasileira de Cineantropometria e Desempenho Humano
spelling doaj.art-00fc4fe20f984663bc1e2f1212ff31be2022-12-21T18:54:55ZengUniversidade Federal de Santa CatarinaRevista Brasileira de Cineantropometria e Desempenho Humano1415-84261980-00372012-05-01143254263<b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254Alexandre Hideki OkanoAntonio Carlos de MoraesBruno de Paula SmirmaulRicardo Okada TrianaEzequiel Moreira GonçalvesLeandro Ricardo AltimariEduardo Bodnariuc FontesThe present study determined the neuromuscular fatigue threshold (NFT) using four different time-periods of analysis of the electromyographic signal and compared these estimations with critical power (CP). Fifteen healthy young men (73.6 ± 5.1 kg, 177.8 ± 7.0 cm, 23.4 ± 5.2 years) performed 3-4 different severe constant workload trials until exhaustion on a cycle ergometer with simultaneous SEMG signals acquisition. The obtained data permitted NFT estimation with four different periods of analysis as follows: initial 30s (T30), 1min (T1), 2min (T2) and total time (TT), as well as CP. T30 and T1 were significantly higher than TT and CP and, T2 and TT did not differ between each other, and both were significantly higher than CP. In addition, TT was significantly correlated to CP (0.72; P < 0.05) and to T2 (0.58; P < 0.05). We conclude that NFT overestimates CP, independent of the time-period analysis used for its determination.http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/21877/21730ElectromyographyExercise testMuscle fatiguePhysical fitnessCondicionamento físicoEletromiografiaFadiga muscularTeste físico.
spellingShingle Alexandre Hideki Okano
Antonio Carlos de Moraes
Bruno de Paula Smirmaul
Ricardo Okada Triana
Ezequiel Moreira Gonçalves
Leandro Ricardo Altimari
Eduardo Bodnariuc Fontes
<b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254
Revista Brasileira de Cineantropometria e Desempenho Humano
Electromyography
Exercise test
Muscle fatigue
Physical fitness
Condicionamento físico
Eletromiografia
Fadiga muscular
Teste físico.
title <b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254
title_full <b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254
title_fullStr <b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254
title_full_unstemmed <b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254
title_short <b>Can neuromuscular fatigue threshold bedetermined by short and non-exhaustive bouts?</b>. DOI: http://dx.doi.org/10.5007/1980-0037.2012v14n3p254
title_sort b can neuromuscular fatigue threshold bedetermined by short and non exhaustive bouts b doi http dx doi org 10 5007 1980 0037 2012v14n3p254
topic Electromyography
Exercise test
Muscle fatigue
Physical fitness
Condicionamento físico
Eletromiografia
Fadiga muscular
Teste físico.
url http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/21877/21730
work_keys_str_mv AT alexandrehidekiokano bcanneuromuscularfatiguethresholdbedeterminedbyshortandnonexhaustiveboutsbdoihttpdxdoiorg105007198000372012v14n3p254
AT antoniocarlosdemoraes bcanneuromuscularfatiguethresholdbedeterminedbyshortandnonexhaustiveboutsbdoihttpdxdoiorg105007198000372012v14n3p254
AT brunodepaulasmirmaul bcanneuromuscularfatiguethresholdbedeterminedbyshortandnonexhaustiveboutsbdoihttpdxdoiorg105007198000372012v14n3p254
AT ricardookadatriana bcanneuromuscularfatiguethresholdbedeterminedbyshortandnonexhaustiveboutsbdoihttpdxdoiorg105007198000372012v14n3p254
AT ezequielmoreiragoncalves bcanneuromuscularfatiguethresholdbedeterminedbyshortandnonexhaustiveboutsbdoihttpdxdoiorg105007198000372012v14n3p254
AT leandroricardoaltimari bcanneuromuscularfatiguethresholdbedeterminedbyshortandnonexhaustiveboutsbdoihttpdxdoiorg105007198000372012v14n3p254
AT eduardobodnariucfontes bcanneuromuscularfatiguethresholdbedeterminedbyshortandnonexhaustiveboutsbdoihttpdxdoiorg105007198000372012v14n3p254