Intra-fractional geometric and dose/volume metric variations of magnetic resonance imaging-guided stereotactic radiotherapy of prostate bed after radical prostatectomy
Background and purpose: Magnetic Resonance Imaging (MRI)-guided Stereotactic body radiotherapy (SBRT) treatment to prostate bed after radical prostatectomy has garnered growing interests. The aim of this study is to evaluate intra-fractional anatomic and dose/volume metric variations for patients re...
Main Authors: | Yu Gao, Stephanie Yoon, Ting Martin Ma, Yingli Yang, Ke Sheng, Daniel A. Low, Leslie Ballas, Michael L. Steinberg, Amar U Kishan, Minsong Cao |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2024-04-01
|
Series: | Physics and Imaging in Radiation Oncology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405631624000435 |
Similar Items
-
Multi-institutional experience treating patients with cardiac devices on a 1.5 Tesla magnetic resonance-linear accelerator and workflow development for thoracic treatments
by: Rick Keesman, et al.
Published: (2024-10-01) -
Clinical outcomes after online adaptive MR-guided stereotactic body radiotherapy for pancreatic tumors on a 1.5 T MR-linac
by: Hidde Eijkelenkamp, et al.
Published: (2023-10-01) -
Motion and dosimetric criteria for selecting gating technique for apical lung lesions in magnetic resonance guided radiotherapy
by: Matteo Galetto, et al.
Published: (2023-11-01) -
MR-guided stereotactic radiation therapy for head and neck cancers
by: He Wang, et al.
Published: (2024-05-01) -
A randomized phase II trial of MR-guided prostate stereotactic body radiotherapy administered in 5 or 2 fractions for localized prostate cancer (FORT)
by: Sydney Wolfe, et al.
Published: (2023-09-01)