On the issue of distortion source identification on the example of a simplified model of electric power system

The relevance of the research is caused the changed structure of energy consumption associated with an increase in the proportion of non-linear loads and the need to reliable determination of distortion sources in the distribution network for the effective functioning of the system of penalties and...

Full description

Bibliographic Details
Main Authors: Anatoly Voloshko, Daniel Filyanin
Format: Article
Language:Russian
Published: Tomsk Polytechnic University 2019-05-01
Series:Известия Томского политехнического университета: Инжиниринг георесурсов
Subjects:
Online Access:http://izvestiya.tpu.ru/archive/article/view/1595
_version_ 1797813259616649216
author Anatoly Voloshko
Daniel Filyanin
author_facet Anatoly Voloshko
Daniel Filyanin
author_sort Anatoly Voloshko
collection DOAJ
description The relevance of the research is caused the changed structure of energy consumption associated with an increase in the proportion of non-linear loads and the need to reliable determination of distortion sources in the distribution network for the effective functioning of the system of penalties and sanctions. The main aim of the study: is to determine the sources of stress curve distortion in the point of common coupling on the example of a simplified model of electric power system. The methods used in the study. The operating modes of the model are calculated using the Simulink application, included in the software package Matlab 2014a. To build the model the authors used a simulation library SimPowerSystem, which includes mathematical models of individual elements of power equipment. When selecting the model parameters of the distribution network the active resistances that simulate cable line and load, were used to simplify the calculations. To determine the magnitude and sign of harmonic power flux the Fourier transform was applied. The results. The authors carried out the review of the existing methods for identification of distortion sources in the point of common coupling of the distribution network; their advantages and disadvantages were defined. On the example of a simplified model of electric power system the authors measured the sign and magnitude of the power of distortion sources in the point of common coupling and at the terminals of consumers with non-distortion and distortion loads. According to the results of the measurements the differences in the values of secondary harmonic power in the point of common coupling and at the terminals of consumers were defined. The authors identified some features of the distortion sources presence in the load and proposed a new approach to identify the sources of harmonics by using a harmonic power flux sense method, according to which it is recommended to move the point of measuring of the secondary harmonic power from the point of common coupling to terminals of consumers.
first_indexed 2024-03-13T07:49:37Z
format Article
id doaj.art-0199cc18d83e47148ada59f8d575505d
institution Directory Open Access Journal
issn 2500-1019
2413-1830
language Russian
last_indexed 2024-03-13T07:49:37Z
publishDate 2019-05-01
publisher Tomsk Polytechnic University
record_format Article
series Известия Томского политехнического университета: Инжиниринг георесурсов
spelling doaj.art-0199cc18d83e47148ada59f8d575505d2023-06-02T21:06:23ZrusTomsk Polytechnic UniversityИзвестия Томского политехнического университета: Инжиниринг георесурсов2500-10192413-18302019-05-013266On the issue of distortion source identification on the example of a simplified model of electric power systemAnatoly VoloshkoDaniel FilyaninThe relevance of the research is caused the changed structure of energy consumption associated with an increase in the proportion of non-linear loads and the need to reliable determination of distortion sources in the distribution network for the effective functioning of the system of penalties and sanctions. The main aim of the study: is to determine the sources of stress curve distortion in the point of common coupling on the example of a simplified model of electric power system. The methods used in the study. The operating modes of the model are calculated using the Simulink application, included in the software package Matlab 2014a. To build the model the authors used a simulation library SimPowerSystem, which includes mathematical models of individual elements of power equipment. When selecting the model parameters of the distribution network the active resistances that simulate cable line and load, were used to simplify the calculations. To determine the magnitude and sign of harmonic power flux the Fourier transform was applied. The results. The authors carried out the review of the existing methods for identification of distortion sources in the point of common coupling of the distribution network; their advantages and disadvantages were defined. On the example of a simplified model of electric power system the authors measured the sign and magnitude of the power of distortion sources in the point of common coupling and at the terminals of consumers with non-distortion and distortion loads. According to the results of the measurements the differences in the values of secondary harmonic power in the point of common coupling and at the terminals of consumers were defined. The authors identified some features of the distortion sources presence in the load and proposed a new approach to identify the sources of harmonics by using a harmonic power flux sense method, according to which it is recommended to move the point of measuring of the secondary harmonic power from the point of common coupling to terminals of consumers.http://izvestiya.tpu.ru/archive/article/view/1595power qualityharmonicsdistortion powertotal harmonic distortiondistortion source
spellingShingle Anatoly Voloshko
Daniel Filyanin
On the issue of distortion source identification on the example of a simplified model of electric power system
Известия Томского политехнического университета: Инжиниринг георесурсов
power quality
harmonics
distortion power
total harmonic distortion
distortion source
title On the issue of distortion source identification on the example of a simplified model of electric power system
title_full On the issue of distortion source identification on the example of a simplified model of electric power system
title_fullStr On the issue of distortion source identification on the example of a simplified model of electric power system
title_full_unstemmed On the issue of distortion source identification on the example of a simplified model of electric power system
title_short On the issue of distortion source identification on the example of a simplified model of electric power system
title_sort on the issue of distortion source identification on the example of a simplified model of electric power system
topic power quality
harmonics
distortion power
total harmonic distortion
distortion source
url http://izvestiya.tpu.ru/archive/article/view/1595
work_keys_str_mv AT anatolyvoloshko ontheissueofdistortionsourceidentificationontheexampleofasimplifiedmodelofelectricpowersystem
AT danielfilyanin ontheissueofdistortionsourceidentificationontheexampleofasimplifiedmodelofelectricpowersystem