Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BB

The in-box LOCA (Loss of Coolant Accident) represents a major safety concern to be addressed in the design of the WCLL-BB (water-cooled lead-lithium breeding blanket). Research activities are ongoing to master the phenomena and processes that occur during the postulated accident, to enhance the pred...

Full description

Bibliographic Details
Main Authors: Marica Eboli, Francesco Galleni, Nicola Forgione, Nicolò Badodi, Antonio Cammi, Alessandro Del Nevo
Format: Article
Language:English
Published: MDPI AG 2021-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/24/8527
_version_ 1797504950842949632
author Marica Eboli
Francesco Galleni
Nicola Forgione
Nicolò Badodi
Antonio Cammi
Alessandro Del Nevo
author_facet Marica Eboli
Francesco Galleni
Nicola Forgione
Nicolò Badodi
Antonio Cammi
Alessandro Del Nevo
author_sort Marica Eboli
collection DOAJ
description The in-box LOCA (Loss of Coolant Accident) represents a major safety concern to be addressed in the design of the WCLL-BB (water-cooled lead-lithium breeding blanket). Research activities are ongoing to master the phenomena and processes that occur during the postulated accident, to enhance the predictive capability and reliability of numerical tools, and to validate computer models, codes, and procedures for their applications. Following these objectives, ENEA designed and built the new separate effects test facility LIFUS5/Mod3. Two experimental campaigns (Series D and Series E) were executed by injecting water at high pressure into a pool of PbLi in WCLL-BB-relevant parameter ranges. The obtained experimental data were used to check the capabilities of the RELAP5 system code to reproduce the pressure transient of a water system, to validate the chemical model of PbLi/water reactions implemented in the modified version of SIMMER codes for fusion application, to investigate the dynamic effects of energy release on the structures, and to provide relevant feedback for the follow-up experimental campaigns. This work presents the experimental data and the numerical simulations of Test E4.1. The results of the test are presented and critically discussed. The code simulations highlight that SIMMER code is able to reproduce the phenomena connected to PbLi/water interaction, and the relevant test parameters are in agreement with the acquired experimental signals. Moreover, the results obtained by the first approach to SIMMER-RELAP5 code-coupling demonstrate its capability of and strength for predicting the transient scenario in complex geometries, considering multiple physical phenomena and minimizing the computational cost.
first_indexed 2024-03-10T04:11:42Z
format Article
id doaj.art-01b46ea0c7524942a2747686beb0a076
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T04:11:42Z
publishDate 2021-12-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-01b46ea0c7524942a2747686beb0a0762023-11-23T08:08:35ZengMDPI AGEnergies1996-10732021-12-011424852710.3390/en14248527Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BBMarica Eboli0Francesco Galleni1Nicola Forgione2Nicolò Badodi3Antonio Cammi4Alessandro Del Nevo5Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Department of Fusion and Technology for Nuclear Safety and Security, 40032 Camugnano, ItalyDepartment of Civil and Industrial Engineering, University of Pisa, 56122 Pisa, ItalyDepartment of Civil and Industrial Engineering, University of Pisa, 56122 Pisa, ItalyDepartment of Energy, Politecnico di Milano, 20156 Milano, ItalyDepartment of Energy, Politecnico di Milano, 20156 Milano, ItalyItalian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Department of Fusion and Technology for Nuclear Safety and Security, 40032 Camugnano, ItalyThe in-box LOCA (Loss of Coolant Accident) represents a major safety concern to be addressed in the design of the WCLL-BB (water-cooled lead-lithium breeding blanket). Research activities are ongoing to master the phenomena and processes that occur during the postulated accident, to enhance the predictive capability and reliability of numerical tools, and to validate computer models, codes, and procedures for their applications. Following these objectives, ENEA designed and built the new separate effects test facility LIFUS5/Mod3. Two experimental campaigns (Series D and Series E) were executed by injecting water at high pressure into a pool of PbLi in WCLL-BB-relevant parameter ranges. The obtained experimental data were used to check the capabilities of the RELAP5 system code to reproduce the pressure transient of a water system, to validate the chemical model of PbLi/water reactions implemented in the modified version of SIMMER codes for fusion application, to investigate the dynamic effects of energy release on the structures, and to provide relevant feedback for the follow-up experimental campaigns. This work presents the experimental data and the numerical simulations of Test E4.1. The results of the test are presented and critically discussed. The code simulations highlight that SIMMER code is able to reproduce the phenomena connected to PbLi/water interaction, and the relevant test parameters are in agreement with the acquired experimental signals. Moreover, the results obtained by the first approach to SIMMER-RELAP5 code-coupling demonstrate its capability of and strength for predicting the transient scenario in complex geometries, considering multiple physical phenomena and minimizing the computational cost.https://www.mdpi.com/1996-1073/14/24/8527SIMMER codeRELAP5 codein-box LOCAWCLL breeding blanketLIFUS5/Mod3
spellingShingle Marica Eboli
Francesco Galleni
Nicola Forgione
Nicolò Badodi
Antonio Cammi
Alessandro Del Nevo
Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BB
Energies
SIMMER code
RELAP5 code
in-box LOCA
WCLL breeding blanket
LIFUS5/Mod3
title Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BB
title_full Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BB
title_fullStr Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BB
title_full_unstemmed Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BB
title_short Experimental and Numerical Results of LIFUS5/Mod3 Series E Test on In-Box LOCA Transient for WCLL-BB
title_sort experimental and numerical results of lifus5 mod3 series e test on in box loca transient for wcll bb
topic SIMMER code
RELAP5 code
in-box LOCA
WCLL breeding blanket
LIFUS5/Mod3
url https://www.mdpi.com/1996-1073/14/24/8527
work_keys_str_mv AT maricaeboli experimentalandnumericalresultsoflifus5mod3seriesetestoninboxlocatransientforwcllbb
AT francescogalleni experimentalandnumericalresultsoflifus5mod3seriesetestoninboxlocatransientforwcllbb
AT nicolaforgione experimentalandnumericalresultsoflifus5mod3seriesetestoninboxlocatransientforwcllbb
AT nicolobadodi experimentalandnumericalresultsoflifus5mod3seriesetestoninboxlocatransientforwcllbb
AT antoniocammi experimentalandnumericalresultsoflifus5mod3seriesetestoninboxlocatransientforwcllbb
AT alessandrodelnevo experimentalandnumericalresultsoflifus5mod3seriesetestoninboxlocatransientforwcllbb