Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections

<p>Abstract</p> <p>Background</p> <p>Recently, IMACCESS<b>®</b> developed a new malaria test (VIKIA Malaria Ag Pf/Pan™), based on the detection of falciparum malaria (HRP-2) and non-falciparum malaria (aldolase).</p> <p>Methods</p> <p>...

Full description

Bibliographic Details
Main Authors: Chou Monidarin, Kim Saorin, Khim Nimol, Chy Sophy, Sum Sarorn, Dourng Dany, Canier Lydie, Nguon Chea, Ménard Didier
Format: Article
Language:English
Published: BMC 2012-08-01
Series:Malaria Journal
Online Access:http://www.malariajournal.com/content/11/1/295
_version_ 1811314440958640128
author Chou Monidarin
Kim Saorin
Khim Nimol
Chy Sophy
Sum Sarorn
Dourng Dany
Canier Lydie
Nguon Chea
Ménard Didier
author_facet Chou Monidarin
Kim Saorin
Khim Nimol
Chy Sophy
Sum Sarorn
Dourng Dany
Canier Lydie
Nguon Chea
Ménard Didier
author_sort Chou Monidarin
collection DOAJ
description <p>Abstract</p> <p>Background</p> <p>Recently, IMACCESS<b>®</b> developed a new malaria test (VIKIA Malaria Ag Pf/Pan™), based on the detection of falciparum malaria (HRP-2) and non-falciparum malaria (aldolase).</p> <p>Methods</p> <p>The performance of this new malaria rapid diagnostic test (RDT) was assessed using 1,000 febrile patients seeking malaria treatment in four health centres in Cambodia from August to December 2011. The results of the VIKIA Malaria Ag Pf/Pan were compared with those obtained by microscopy, the CareStart Malaria™ RDT (AccessBio®) which is currently used in Cambodia, and real-time PCR (as “gold standard”).</p> <p>Results</p> <p>The best performances of the VIKIA Malaria Ag Pf/Pan™ test for detection of both <it>Plasmodium falciparum</it> and non-<it>P. falciparum</it> were with 20–30 min reading times (sensitivity of 93.4% for <it>P. falciparum</it> and 82.8% for non-<it>P. falciparum</it> and specificity of 98.6% for <it>P. falciparum</it> and 98.9% for non-<it>P. falciparum</it>) and were similar to those for the CareStart Malaria™ test.</p> <p>Conclusions</p> <p>This new RDT performs similarly well as other commercially available tests (especially the CareStart Malaria™ test, used as comparator), and conforms to the World Health Organization’s recommendations for RDT performance. It is a good alternative tool for the diagnosis of malaria in endemic areas.</p>
first_indexed 2024-04-13T11:11:44Z
format Article
id doaj.art-01d7990e2b5c4a2e9253dfd5a6de3ac2
institution Directory Open Access Journal
issn 1475-2875
language English
last_indexed 2024-04-13T11:11:44Z
publishDate 2012-08-01
publisher BMC
record_format Article
series Malaria Journal
spelling doaj.art-01d7990e2b5c4a2e9253dfd5a6de3ac22022-12-22T02:49:05ZengBMCMalaria Journal1475-28752012-08-0111129510.1186/1475-2875-11-295Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infectionsChou MonidarinKim SaorinKhim NimolChy SophySum SarornDourng DanyCanier LydieNguon CheaMénard Didier<p>Abstract</p> <p>Background</p> <p>Recently, IMACCESS<b>®</b> developed a new malaria test (VIKIA Malaria Ag Pf/Pan™), based on the detection of falciparum malaria (HRP-2) and non-falciparum malaria (aldolase).</p> <p>Methods</p> <p>The performance of this new malaria rapid diagnostic test (RDT) was assessed using 1,000 febrile patients seeking malaria treatment in four health centres in Cambodia from August to December 2011. The results of the VIKIA Malaria Ag Pf/Pan were compared with those obtained by microscopy, the CareStart Malaria™ RDT (AccessBio®) which is currently used in Cambodia, and real-time PCR (as “gold standard”).</p> <p>Results</p> <p>The best performances of the VIKIA Malaria Ag Pf/Pan™ test for detection of both <it>Plasmodium falciparum</it> and non-<it>P. falciparum</it> were with 20–30 min reading times (sensitivity of 93.4% for <it>P. falciparum</it> and 82.8% for non-<it>P. falciparum</it> and specificity of 98.6% for <it>P. falciparum</it> and 98.9% for non-<it>P. falciparum</it>) and were similar to those for the CareStart Malaria™ test.</p> <p>Conclusions</p> <p>This new RDT performs similarly well as other commercially available tests (especially the CareStart Malaria™ test, used as comparator), and conforms to the World Health Organization’s recommendations for RDT performance. It is a good alternative tool for the diagnosis of malaria in endemic areas.</p>http://www.malariajournal.com/content/11/1/295
spellingShingle Chou Monidarin
Kim Saorin
Khim Nimol
Chy Sophy
Sum Sarorn
Dourng Dany
Canier Lydie
Nguon Chea
Ménard Didier
Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections
Malaria Journal
title Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections
title_full Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections
title_fullStr Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections
title_full_unstemmed Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections
title_short Performance of “VIKIA Malaria Ag Pf/Pan” (IMACCESS®), a new malaria rapid diagnostic test for detection of symptomatic malaria infections
title_sort performance of vikia malaria ag pf pan imaccess r a new malaria rapid diagnostic test for detection of symptomatic malaria infections
url http://www.malariajournal.com/content/11/1/295
work_keys_str_mv AT choumonidarin performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT kimsaorin performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT khimnimol performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT chysophy performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT sumsarorn performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT dourngdany performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT canierlydie performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT nguonchea performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections
AT menarddidier performanceofvikiamalariaagpfpanimaccessanewmalariarapiddiagnostictestfordetectionofsymptomaticmalariainfections