Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and Sapporo

The Local Climate Zone (LCZ) classification system is used in this study to analyze the impacts of urban morphology on a surface urban heat island (SUHI). Our study involved a comparative analysis of SUHI effects in two Japanese cities, Sapporo and Hiroshima, between 2000 to 2022. We used geographic...

Full description

Bibliographic Details
Main Authors: Neshat Rahmani, Ayyoob Sharifi
Format: Article
Language:English
Published: MDPI AG 2023-07-01
Series:Climate
Subjects:
Online Access:https://www.mdpi.com/2225-1154/11/7/142
_version_ 1797589701846106112
author Neshat Rahmani
Ayyoob Sharifi
author_facet Neshat Rahmani
Ayyoob Sharifi
author_sort Neshat Rahmani
collection DOAJ
description The Local Climate Zone (LCZ) classification system is used in this study to analyze the impacts of urban morphology on a surface urban heat island (SUHI). Our study involved a comparative analysis of SUHI effects in two Japanese cities, Sapporo and Hiroshima, between 2000 to 2022. We used geographical-information-system (GIS) mapping techniques to measure temporal LST changes using Landsat 7 and 8 images during the summer’s hottest month (August) and classified the study area into LCZ classes using The World Urban Database and Access Portal Tools (WUDAPT) method with Google Earth Pro. The urban thermal field variance index (UTFVI) is used to examine each LCZ’s thermal comfort level, and the SUHI heat spots (HS) in each LCZ classes are identified. The research findings indicate that the mean LST in Sapporo only experienced a 0.5 °C increase over the time, while the mean LST increased by 1.8 °C in Hiroshima City between 2000 and 2022. In 2000, open low-rise (LCZ 6) areas in Sapporo were the hottest, but by 2022, heavy industry (LCZ 10) became the hottest. In Hiroshima, compact mid-rise (LCZ 2) areas were the hottest in 2000, but by 2022, heavy-industry areas took the lead. The study found that LCZ 10, LCZ 8, LCZ E, and LCZ 3 areas in both Dfa and Cfa climate classifications had unfavorable UTFVI conditions. This was attributed to factors such as a high concentration of heat-absorbing materials, impervious surfaces, and limited green spaces. The majority of the SUHI HS and areas with the highest surface temperatures were situated near industrial zones and large low-rise urban forms in both cities. The study offers valuable insights into the potential long-term effects of various urban forms on the SUHI phenomenon.
first_indexed 2024-03-11T01:10:18Z
format Article
id doaj.art-024649c738544c3b8e9ae1e4e9bec0b0
institution Directory Open Access Journal
issn 2225-1154
language English
last_indexed 2024-03-11T01:10:18Z
publishDate 2023-07-01
publisher MDPI AG
record_format Article
series Climate
spelling doaj.art-024649c738544c3b8e9ae1e4e9bec0b02023-11-18T18:51:44ZengMDPI AGClimate2225-11542023-07-0111714210.3390/cli11070142Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and SapporoNeshat Rahmani0Ayyoob Sharifi1Graduate School of Advanced Science and Engineering, Hiroshima University, Hiroshima 739-8511, JapanThe IDEC Institute, and Network for Education and Research on Peace and Sustainability (NERPS), Hiroshima University, Hiroshima 739-8529, JapanThe Local Climate Zone (LCZ) classification system is used in this study to analyze the impacts of urban morphology on a surface urban heat island (SUHI). Our study involved a comparative analysis of SUHI effects in two Japanese cities, Sapporo and Hiroshima, between 2000 to 2022. We used geographical-information-system (GIS) mapping techniques to measure temporal LST changes using Landsat 7 and 8 images during the summer’s hottest month (August) and classified the study area into LCZ classes using The World Urban Database and Access Portal Tools (WUDAPT) method with Google Earth Pro. The urban thermal field variance index (UTFVI) is used to examine each LCZ’s thermal comfort level, and the SUHI heat spots (HS) in each LCZ classes are identified. The research findings indicate that the mean LST in Sapporo only experienced a 0.5 °C increase over the time, while the mean LST increased by 1.8 °C in Hiroshima City between 2000 and 2022. In 2000, open low-rise (LCZ 6) areas in Sapporo were the hottest, but by 2022, heavy industry (LCZ 10) became the hottest. In Hiroshima, compact mid-rise (LCZ 2) areas were the hottest in 2000, but by 2022, heavy-industry areas took the lead. The study found that LCZ 10, LCZ 8, LCZ E, and LCZ 3 areas in both Dfa and Cfa climate classifications had unfavorable UTFVI conditions. This was attributed to factors such as a high concentration of heat-absorbing materials, impervious surfaces, and limited green spaces. The majority of the SUHI HS and areas with the highest surface temperatures were situated near industrial zones and large low-rise urban forms in both cities. The study offers valuable insights into the potential long-term effects of various urban forms on the SUHI phenomenon.https://www.mdpi.com/2225-1154/11/7/142surface urban heat island (SUHI)local climate zones (LCZs)land surface temperature (LST)climate change adaptationSapporoHiroshima
spellingShingle Neshat Rahmani
Ayyoob Sharifi
Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and Sapporo
Climate
surface urban heat island (SUHI)
local climate zones (LCZs)
land surface temperature (LST)
climate change adaptation
Sapporo
Hiroshima
title Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and Sapporo
title_full Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and Sapporo
title_fullStr Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and Sapporo
title_full_unstemmed Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and Sapporo
title_short Comparative Analysis of the Surface Urban Heat Island (SUHI) Effect Based on the Local Climate Zone (LCZ) Classification Scheme for Two Japanese Cities, Hiroshima, and Sapporo
title_sort comparative analysis of the surface urban heat island suhi effect based on the local climate zone lcz classification scheme for two japanese cities hiroshima and sapporo
topic surface urban heat island (SUHI)
local climate zones (LCZs)
land surface temperature (LST)
climate change adaptation
Sapporo
Hiroshima
url https://www.mdpi.com/2225-1154/11/7/142
work_keys_str_mv AT neshatrahmani comparativeanalysisofthesurfaceurbanheatislandsuhieffectbasedonthelocalclimatezonelczclassificationschemefortwojapanesecitieshiroshimaandsapporo
AT ayyoobsharifi comparativeanalysisofthesurfaceurbanheatislandsuhieffectbasedonthelocalclimatezonelczclassificationschemefortwojapanesecitieshiroshimaandsapporo