ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРА
The object of research is a three-phase shunt active power filter, which consists of a semiconductor voltage inverter on fully controllable switches, capacitive storage, and an RL-link. The carried-out decomposition of the research object according to the rate of motion of the dynamic system makes i...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Electrodynamics of the National Academy of Sciences of Ukraine
2021-05-01
|
Series: | Праці Інституту електродинаміки Національної академії наук України |
Subjects: | |
Online Access: | https://prc.ied.org.ua/index.php/proceedings/article/view/24 |
_version_ | 1797950847520342016 |
---|---|
author | К.І. Денисенко В.О. Лесик Т.В. Мисак |
author_facet | К.І. Денисенко В.О. Лесик Т.В. Мисак |
author_sort | К.І. Денисенко |
collection | DOAJ |
description | The object of research is a three-phase shunt active power filter, which consists of a semiconductor voltage inverter on fully controllable switches, capacitive storage, and an RL-link. The carried-out decomposition of the research object according to the rate of motion of the dynamic system makes it possible to divide this dynamic system into two subsystems, interconnected by control. The role and influence of the communication subsystem between the voltage stabilization circuit on the storage capacitor of the three-phase shunt active power filter and the circuits for the formation of the compensation current, which is injected by this filter into the distributed power supply network, is considered. The presence of a non-linear load in this network is a source of distortion of the parameters of electrical energy. The formation of the compensation current by the forced introduction of the first order sliding modes along some sliding surfaces was carried out. The two-dimensional sliding surface is a linear combination of the components of the two-dimensional error vectors of the compensation current and the first derivative of the error of this current. The introduced communication subsystem makes it possible to reduce the influence of the disturbance in the form of harmonic components of the rectified voltage on the parameters of the compensating current. The influence of the dynamic characteristics of a communication subsystem with filtering properties on the performance indicators of a parallel active filter and the current distortion factor in the power supply network to which this filter is connected was analyzed. To confirm the theoretical assumptions, a simulation model was built and the results of digital modeling were analyzed. Comparison of different types of filters as a communication subsystem according to the criteria of the duration of the transient process and the harmonic distortion in the current that consumed from the network was carried out. References 26, figures 4, tables 3. |
first_indexed | 2024-04-10T22:21:33Z |
format | Article |
id | doaj.art-02a195eec70e4c25b25f06487da3da46 |
institution | Directory Open Access Journal |
issn | 1727-9895 2786-7064 |
language | English |
last_indexed | 2024-04-10T22:21:33Z |
publishDate | 2021-05-01 |
publisher | Institute of Electrodynamics of the National Academy of Sciences of Ukraine |
record_format | Article |
series | Праці Інституту електродинаміки Національної академії наук України |
spelling | doaj.art-02a195eec70e4c25b25f06487da3da462023-01-17T14:35:02ZengInstitute of Electrodynamics of the National Academy of Sciences of UkraineПраці Інституту електродинаміки Національної академії наук України1727-98952786-70642021-05-01585565https://doi.org/10.15407/publishing2021.58.055ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРАК.І. Денисенко0В.О. Лесик1Т.В. Мисак2https://orcid.org/0000-0002-3140-971XІнститут електродинаміки НАН України, пр. Перемоги, 56, Київ-57, 03057, УкраїнаІнститут електродинаміки НАН України, пр. Перемоги, 56, Київ, 03057, УкраїнаІнститут електродинаміки НАН України, пр. Перемоги, 56, Київ, 03057, УкраїнаThe object of research is a three-phase shunt active power filter, which consists of a semiconductor voltage inverter on fully controllable switches, capacitive storage, and an RL-link. The carried-out decomposition of the research object according to the rate of motion of the dynamic system makes it possible to divide this dynamic system into two subsystems, interconnected by control. The role and influence of the communication subsystem between the voltage stabilization circuit on the storage capacitor of the three-phase shunt active power filter and the circuits for the formation of the compensation current, which is injected by this filter into the distributed power supply network, is considered. The presence of a non-linear load in this network is a source of distortion of the parameters of electrical energy. The formation of the compensation current by the forced introduction of the first order sliding modes along some sliding surfaces was carried out. The two-dimensional sliding surface is a linear combination of the components of the two-dimensional error vectors of the compensation current and the first derivative of the error of this current. The introduced communication subsystem makes it possible to reduce the influence of the disturbance in the form of harmonic components of the rectified voltage on the parameters of the compensating current. The influence of the dynamic characteristics of a communication subsystem with filtering properties on the performance indicators of a parallel active filter and the current distortion factor in the power supply network to which this filter is connected was analyzed. To confirm the theoretical assumptions, a simulation model was built and the results of digital modeling were analyzed. Comparison of different types of filters as a communication subsystem according to the criteria of the duration of the transient process and the harmonic distortion in the current that consumed from the network was carried out. References 26, figures 4, tables 3.https://prc.ied.org.ua/index.php/proceedings/article/view/24shunt active filtersliding modecompensation currentlow-pass filterspeedcoefficient of distortion |
spellingShingle | К.І. Денисенко В.О. Лесик Т.В. Мисак ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРА Праці Інституту електродинаміки Національної академії наук України shunt active filter sliding mode compensation current low-pass filter speed coefficient of distortion |
title | ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРА |
title_full | ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРА |
title_fullStr | ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРА |
title_full_unstemmed | ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРА |
title_short | ВПЛИВ ФІЛЬТРА В КАНАЛІ КЕРУВАННЯ КОНТУРОМ СТАБІЛІЗАЦІЇ НАПРУГИ НАКОПИЧУВАЛЬНОГО КОНДЕНСАТОРА НА ДИНАМІКУ ТРИФАЗНОГО ПАРАЛЕЛЬНОГО АКТИВНОГО ФІЛЬТРА |
title_sort | вплив фільтра в каналі керування контуром стабілізації напруги накопичувального конденсатора на динаміку трифазного паралельного активного фільтра |
topic | shunt active filter sliding mode compensation current low-pass filter speed coefficient of distortion |
url | https://prc.ied.org.ua/index.php/proceedings/article/view/24 |
work_keys_str_mv | AT kídenisenko vplivfílʹtravkanalíkeruvannâkonturomstabílízacíínapruginakopičuvalʹnogokondensatoranadinamíkutrifaznogoparalelʹnogoaktivnogofílʹtra AT volesik vplivfílʹtravkanalíkeruvannâkonturomstabílízacíínapruginakopičuvalʹnogokondensatoranadinamíkutrifaznogoparalelʹnogoaktivnogofílʹtra AT tvmisak vplivfílʹtravkanalíkeruvannâkonturomstabílízacíínapruginakopičuvalʹnogokondensatoranadinamíkutrifaznogoparalelʹnogoaktivnogofílʹtra |