Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measu...

Full description

Bibliographic Details
Main Authors: Maria Magdalena Dresler, Jacek Kociszewski, Edyta Wlaźlak, Piotr Pędraszewski, Agnieszka Trzeciak, Grzegorz Surkont
Format: Article
Language:English
Published: Sciendo 2017-06-01
Series:Journal of Ultrasonography
Subjects:
Online Access:http://jultrason.pl/index.php/issues/volume-17-no-69/repeatability-and-reproducibility-of-measurements-of-the-suburethral-tape-location-obtained-in-pelvic-floor-ultrasound-performed-with-a-transvaginal-probe?aid=513
_version_ 1818508148169768960
author Maria Magdalena Dresler
Jacek Kociszewski
Edyta Wlaźlak
Piotr Pędraszewski
Agnieszka Trzeciak
Grzegorz Surkont
author_facet Maria Magdalena Dresler
Jacek Kociszewski
Edyta Wlaźlak
Piotr Pędraszewski
Agnieszka Trzeciak
Grzegorz Surkont
author_sort Maria Magdalena Dresler
collection DOAJ
description Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.
first_indexed 2024-12-10T22:27:44Z
format Article
id doaj.art-0310c756da7042a39ae0dbcc7e8aabcc
institution Directory Open Access Journal
issn 2084-8404
2451-070X
language English
last_indexed 2024-12-10T22:27:44Z
publishDate 2017-06-01
publisher Sciendo
record_format Article
series Journal of Ultrasonography
spelling doaj.art-0310c756da7042a39ae0dbcc7e8aabcc2022-12-22T01:31:07ZengSciendoJournal of Ultrasonography2084-84042451-070X2017-06-01176910110510.15557/JoU.2017.0014Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probeMaria Magdalena Dresler0Jacek Kociszewski1Edyta Wlaźlak2Piotr Pędraszewski3Agnieszka Trzeciak4Grzegorz Surkont5Ultrasound Diagnostics Laboratory, Division of Operative Gynecology and Gynecologic Oncology, Gynecology and Obstetrics Department, Medical University of Łódź, PolandFrauenklinik, Evangelisches Krankenhaus Hagen-HaspeGmbH, Hagen, GermanyUltrasound Diagnostics Laboratory, Division of Operative Gynecology and Gynecologic Oncology, Gynecology and Obstetrics Department, Medical University of Łódź, PolandGynecology and Obstetrics Unit, Voivodeship Hospital Complex, Płock, PolandMedical Center, Remedium Municipal Outpatient Center, Głowno, PolandUltrasound Diagnostics Laboratory, Division of Operative Gynecology and Gynecologic Oncology, Gynecology and Obstetrics Department, Medical University of Łódź, PolandIntroduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.http://jultrason.pl/index.php/issues/volume-17-no-69/repeatability-and-reproducibility-of-measurements-of-the-suburethral-tape-location-obtained-in-pelvic-floor-ultrasound-performed-with-a-transvaginal-probe?aid=513pelvic ultrasoundurogynecologysuburethral taperepeatabilitytransvaginal probe
spellingShingle Maria Magdalena Dresler
Jacek Kociszewski
Edyta Wlaźlak
Piotr Pędraszewski
Agnieszka Trzeciak
Grzegorz Surkont
Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
Journal of Ultrasonography
pelvic ultrasound
urogynecology
suburethral tape
repeatability
transvaginal probe
title Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_full Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_fullStr Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_full_unstemmed Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_short Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_sort repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
topic pelvic ultrasound
urogynecology
suburethral tape
repeatability
transvaginal probe
url http://jultrason.pl/index.php/issues/volume-17-no-69/repeatability-and-reproducibility-of-measurements-of-the-suburethral-tape-location-obtained-in-pelvic-floor-ultrasound-performed-with-a-transvaginal-probe?aid=513
work_keys_str_mv AT mariamagdalenadresler repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT jacekkociszewski repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT edytawlazlak repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT piotrpedraszewski repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT agnieszkatrzeciak repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT grzegorzsurkont repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe