Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia

Ghada A Nassar,1 Ezzat N Abbas,2 Mahmoud Mohammed Ahmed Ali Khalil,2 Ehab Tharwat,2 Ahmed R Mohammed2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, Egypt; 2Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, EgyptCorrespondence: Ghada A Nassar,...

Full description

Bibliographic Details
Main Authors: Nassar GA, Abbas EN, Khalil MMAA, Tharwat E, Mohammed AR
Format: Article
Language:English
Published: Dove Medical Press 2023-04-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/evaluation-of-higher-order-aberrations-and-anterior-segment-parameters-peer-reviewed-fulltext-article-OPTH
_version_ 1827968798261510144
author Nassar GA
Abbas EN
Khalil MMAA
Tharwat E
Mohammed AR
author_facet Nassar GA
Abbas EN
Khalil MMAA
Tharwat E
Mohammed AR
author_sort Nassar GA
collection DOAJ
description Ghada A Nassar,1 Ezzat N Abbas,2 Mahmoud Mohammed Ahmed Ali Khalil,2 Ehab Tharwat,2 Ahmed R Mohammed2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, Egypt; 2Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, EgyptCorrespondence: Ghada A Nassar, 10 Said Street, Heliopolis, Cairo, 11757, Egypt, Tel +2 01222397300, Fax +20223636504, Email ghada.azab2010@gmail.comPurpose: To evaluate changes in higher order aberrations (HOAs) induced by implantable collamer lens (ICL) implantation in correction of high myopia and to compare the anterior segment parameters before and after surgery. Also, to correlate these parameters with HOAs, the best corrected visual acuity (BCVA) and intraocular pressure (IOP).Methods: This prospective interventional cohort case series study included 40 eyes with high myopia that underwent ICL V4c implantation. They were evaluated pre-operatively and post-operatively at 1st and 3rd month HOAs using Scheimpflug Sirius Camera. The anterior segment parameters were evaluated by optical biometry. Correlations between HOAs, BCVA and anterior segment parameters were evaluated.Results: The mean pre-operative BCVA was 0.67 ± 0.17, while post-operative BCVA was 0.74 ± 0.16 (p-value < 0.001). The spherical equivalent was − 13.66 ± 2.23 pre-operatively, while post-operatively it was − 0.77 ± 0.65 (p-value < 0.001). The mean pre-operative root mean square (RMS) of HOAs was 0.62 ± 0.11 μm, while mean post-operative RMS in the 1st month was 0.82 ± 0.29 μm (p-value < 0.001). At 3rd month, it was 0.63 ± 0.17 μm (p-value = 0.685). The mean pre-operative anterior chamber depth (ACD) was 3.66 ± 0.26 mm. It decreased in the post-operative 1st month to 3.46 ± 0.30 mm, while in 3rd month 3.45 ± 0.24 mm (p-value < 0.001, < 0.001) respectively. The mean pre-operative anterior chamber angle (ACA) 45.98 ± 8.39 o while, the mean ACA was 31.65 ± 4.14, 31.03 ± 3.74 post-operatively (p-value < 0.001, < 0.001) respectively. There was significant increase in IOP (p-value < 0.001).Conclusion: ICL implantation is safe and effective in correction of high myopia, as HOAs increase at first month post-operatively then, return to the pre-operative level by 3rd month. However, anterior segment parameters show significant changes which may need longer follow up.Keywords: implantable collamer lens, higher order aberrations, anterior segment parameters, Scheimpflug Sirius Camera, optical biometry, ICL, HOA
first_indexed 2024-04-09T18:28:16Z
format Article
id doaj.art-0358784b82674fb798e7ce99e1eaa6f1
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-04-09T18:28:16Z
publishDate 2023-04-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-0358784b82674fb798e7ce99e1eaa6f12023-04-11T19:05:00ZengDove Medical PressClinical Ophthalmology1177-54832023-04-01Volume 171097110782929Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High MyopiaNassar GAAbbas ENKhalil MMAATharwat EMohammed ARGhada A Nassar,1 Ezzat N Abbas,2 Mahmoud Mohammed Ahmed Ali Khalil,2 Ehab Tharwat,2 Ahmed R Mohammed2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, Egypt; 2Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, EgyptCorrespondence: Ghada A Nassar, 10 Said Street, Heliopolis, Cairo, 11757, Egypt, Tel +2 01222397300, Fax +20223636504, Email ghada.azab2010@gmail.comPurpose: To evaluate changes in higher order aberrations (HOAs) induced by implantable collamer lens (ICL) implantation in correction of high myopia and to compare the anterior segment parameters before and after surgery. Also, to correlate these parameters with HOAs, the best corrected visual acuity (BCVA) and intraocular pressure (IOP).Methods: This prospective interventional cohort case series study included 40 eyes with high myopia that underwent ICL V4c implantation. They were evaluated pre-operatively and post-operatively at 1st and 3rd month HOAs using Scheimpflug Sirius Camera. The anterior segment parameters were evaluated by optical biometry. Correlations between HOAs, BCVA and anterior segment parameters were evaluated.Results: The mean pre-operative BCVA was 0.67 ± 0.17, while post-operative BCVA was 0.74 ± 0.16 (p-value < 0.001). The spherical equivalent was − 13.66 ± 2.23 pre-operatively, while post-operatively it was − 0.77 ± 0.65 (p-value < 0.001). The mean pre-operative root mean square (RMS) of HOAs was 0.62 ± 0.11 μm, while mean post-operative RMS in the 1st month was 0.82 ± 0.29 μm (p-value < 0.001). At 3rd month, it was 0.63 ± 0.17 μm (p-value = 0.685). The mean pre-operative anterior chamber depth (ACD) was 3.66 ± 0.26 mm. It decreased in the post-operative 1st month to 3.46 ± 0.30 mm, while in 3rd month 3.45 ± 0.24 mm (p-value < 0.001, < 0.001) respectively. The mean pre-operative anterior chamber angle (ACA) 45.98 ± 8.39 o while, the mean ACA was 31.65 ± 4.14, 31.03 ± 3.74 post-operatively (p-value < 0.001, < 0.001) respectively. There was significant increase in IOP (p-value < 0.001).Conclusion: ICL implantation is safe and effective in correction of high myopia, as HOAs increase at first month post-operatively then, return to the pre-operative level by 3rd month. However, anterior segment parameters show significant changes which may need longer follow up.Keywords: implantable collamer lens, higher order aberrations, anterior segment parameters, Scheimpflug Sirius Camera, optical biometry, ICL, HOAhttps://www.dovepress.com/evaluation-of-higher-order-aberrations-and-anterior-segment-parameters-peer-reviewed-fulltext-article-OPTHimplantable collamer lens – higher order aberrations – anterior segment parameters - scheimpflug sirius camera – optical biometry.
spellingShingle Nassar GA
Abbas EN
Khalil MMAA
Tharwat E
Mohammed AR
Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia
Clinical Ophthalmology
implantable collamer lens – higher order aberrations – anterior segment parameters - scheimpflug sirius camera – optical biometry.
title Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia
title_full Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia
title_fullStr Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia
title_full_unstemmed Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia
title_short Evaluation of Higher Order Aberrations and Anterior Segment Parameters Changes After Implantable Collamer Lens Implantation for High Myopia
title_sort evaluation of higher order aberrations and anterior segment parameters changes after implantable collamer lens implantation for high myopia
topic implantable collamer lens – higher order aberrations – anterior segment parameters - scheimpflug sirius camera – optical biometry.
url https://www.dovepress.com/evaluation-of-higher-order-aberrations-and-anterior-segment-parameters-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT nassarga evaluationofhigherorderaberrationsandanteriorsegmentparameterschangesafterimplantablecollamerlensimplantationforhighmyopia
AT abbasen evaluationofhigherorderaberrationsandanteriorsegmentparameterschangesafterimplantablecollamerlensimplantationforhighmyopia
AT khalilmmaa evaluationofhigherorderaberrationsandanteriorsegmentparameterschangesafterimplantablecollamerlensimplantationforhighmyopia
AT tharwate evaluationofhigherorderaberrationsandanteriorsegmentparameterschangesafterimplantablecollamerlensimplantationforhighmyopia
AT mohammedar evaluationofhigherorderaberrationsandanteriorsegmentparameterschangesafterimplantablecollamerlensimplantationforhighmyopia