Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid

Introduction: Albumin is the protein that marks the passage of cerebrospinal fluid proteins into the serum. Materials and methods: Serum albumin was quantified by bromocresol green dye technique and by using the modified microalbuminuria method and for protein in cerebrospinal fluid, the pyrogallo...

Full description

Bibliographic Details
Main Authors: Vanessa Pérez-del-Vallìn, José Alejandro Rodríguez-Pérez, Alejandro Mirabal-Viel, Christian Meijides-Mejías, Jairo Lumpuy-Castillo, William Castillo-González, Alberto Juan Dorta-Contreras
Format: Article
Language:Spanish
Published: Centro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED) 2019-05-01
Series:Revista Cubana de Investigaciones Biomédicas
Online Access:http://www.revibiomedica.sld.cu/index.php/ibi/article/view/106
_version_ 1818201897674211328
author Vanessa Pérez-del-Vallìn
José Alejandro Rodríguez-Pérez
Alejandro Mirabal-Viel
Christian Meijides-Mejías
Jairo Lumpuy-Castillo
William Castillo-González
Alberto Juan Dorta-Contreras
author_facet Vanessa Pérez-del-Vallìn
José Alejandro Rodríguez-Pérez
Alejandro Mirabal-Viel
Christian Meijides-Mejías
Jairo Lumpuy-Castillo
William Castillo-González
Alberto Juan Dorta-Contreras
author_sort Vanessa Pérez-del-Vallìn
collection DOAJ
description Introduction: Albumin is the protein that marks the passage of cerebrospinal fluid proteins into the serum. Materials and methods: Serum albumin was quantified by bromocresol green dye technique and by using the modified microalbuminuria method and for protein in cerebrospinal fluid, the pyrogallol molybdate red complex technique and the bromocresol green method were used. Results: Compared methods in serum, the modified ELISA method had a sensitivity of 100%, a specificity of 80% and the cut-off point was less than or equal to 58 g / L. In both fluids the bromocresol green method had a sensitivity of 72.7%, specificity of 60% and the cut-off point was greater than 34g / L. The areas under the ROC curves of the two methods did not show significant differences for p = 0.074. In the methods for protein in cerebrospinal fluid the pyrogallol molybdate red complex had a sensitivity of 88.9% and a specificity of 90.5 and the cut-off point was less than or equal to 960mg / L and the bromocresol green method had a sensitivity of 66.7, a specificity of 85.7 and a cut-off point less than or equal to 700mg / L. The comparison between the ROC curves of the two methods studied was significant with p=0.138. Conclusions: The modified ELISA method is better than the bromocresol green method for protein in terms of specificity and sensitivity and in methods for quantifying serum albumin both methods do not show significant differences and have lower specificity and sensitivity than methods for quantifying protein in cerebrospinal fluid.
first_indexed 2024-12-12T03:00:51Z
format Article
id doaj.art-036ce85f79da4bb099c17bfde0150ae4
institution Directory Open Access Journal
issn 0864-0300
1561-3011
language Spanish
last_indexed 2024-12-12T03:00:51Z
publishDate 2019-05-01
publisher Centro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED)
record_format Article
series Revista Cubana de Investigaciones Biomédicas
spelling doaj.art-036ce85f79da4bb099c17bfde0150ae42022-12-22T00:40:38ZspaCentro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED)Revista Cubana de Investigaciones Biomédicas0864-03001561-30112019-05-01381119Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal FluidVanessa Pérez-del-Vallìn0José Alejandro Rodríguez-PérezAlejandro Mirabal-VielChristian Meijides-MejíasJairo Lumpuy-CastilloWilliam Castillo-GonzálezAlberto Juan Dorta-ContrerasLaboratorio Centrales de Lìquido Cefalorraquìdeo (LABCEL) Universidad de Ciencias Médicas de La Habana, Facultad Miguel Enrìquez.Introduction: Albumin is the protein that marks the passage of cerebrospinal fluid proteins into the serum. Materials and methods: Serum albumin was quantified by bromocresol green dye technique and by using the modified microalbuminuria method and for protein in cerebrospinal fluid, the pyrogallol molybdate red complex technique and the bromocresol green method were used. Results: Compared methods in serum, the modified ELISA method had a sensitivity of 100%, a specificity of 80% and the cut-off point was less than or equal to 58 g / L. In both fluids the bromocresol green method had a sensitivity of 72.7%, specificity of 60% and the cut-off point was greater than 34g / L. The areas under the ROC curves of the two methods did not show significant differences for p = 0.074. In the methods for protein in cerebrospinal fluid the pyrogallol molybdate red complex had a sensitivity of 88.9% and a specificity of 90.5 and the cut-off point was less than or equal to 960mg / L and the bromocresol green method had a sensitivity of 66.7, a specificity of 85.7 and a cut-off point less than or equal to 700mg / L. The comparison between the ROC curves of the two methods studied was significant with p=0.138. Conclusions: The modified ELISA method is better than the bromocresol green method for protein in terms of specificity and sensitivity and in methods for quantifying serum albumin both methods do not show significant differences and have lower specificity and sensitivity than methods for quantifying protein in cerebrospinal fluid.http://www.revibiomedica.sld.cu/index.php/ibi/article/view/106
spellingShingle Vanessa Pérez-del-Vallìn
José Alejandro Rodríguez-Pérez
Alejandro Mirabal-Viel
Christian Meijides-Mejías
Jairo Lumpuy-Castillo
William Castillo-González
Alberto Juan Dorta-Contreras
Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid
Revista Cubana de Investigaciones Biomédicas
title Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid
title_full Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid
title_fullStr Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid
title_full_unstemmed Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid
title_short Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid
title_sort comparison of methods for the quantification of albumin in serum and total protein in cerebrospinal fluid
url http://www.revibiomedica.sld.cu/index.php/ibi/article/view/106
work_keys_str_mv AT vanessaperezdelvallin comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid
AT josealejandrorodriguezperez comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid
AT alejandromirabalviel comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid
AT christianmeijidesmejias comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid
AT jairolumpuycastillo comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid
AT williamcastillogonzalez comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid
AT albertojuandortacontreras comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid