Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid
Introduction: Albumin is the protein that marks the passage of cerebrospinal fluid proteins into the serum. Materials and methods: Serum albumin was quantified by bromocresol green dye technique and by using the modified microalbuminuria method and for protein in cerebrospinal fluid, the pyrogallo...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | Spanish |
Published: |
Centro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED)
2019-05-01
|
Series: | Revista Cubana de Investigaciones Biomédicas |
Online Access: | http://www.revibiomedica.sld.cu/index.php/ibi/article/view/106 |
_version_ | 1818201897674211328 |
---|---|
author | Vanessa Pérez-del-Vallìn José Alejandro Rodríguez-Pérez Alejandro Mirabal-Viel Christian Meijides-Mejías Jairo Lumpuy-Castillo William Castillo-González Alberto Juan Dorta-Contreras |
author_facet | Vanessa Pérez-del-Vallìn José Alejandro Rodríguez-Pérez Alejandro Mirabal-Viel Christian Meijides-Mejías Jairo Lumpuy-Castillo William Castillo-González Alberto Juan Dorta-Contreras |
author_sort | Vanessa Pérez-del-Vallìn |
collection | DOAJ |
description | Introduction: Albumin is the protein that marks the passage of cerebrospinal fluid proteins into the serum.
Materials and methods: Serum albumin was quantified by bromocresol green dye technique and by using the modified microalbuminuria method and for protein in cerebrospinal fluid, the pyrogallol molybdate red complex technique and the bromocresol green method were used.
Results: Compared methods in serum, the modified ELISA method had a sensitivity of 100%, a specificity of 80% and the cut-off point was less than or equal to 58 g / L. In both fluids the bromocresol green method had a sensitivity of 72.7%, specificity of 60% and the cut-off point was greater than 34g / L. The areas under the ROC curves of the two methods did not show significant differences for p = 0.074. In the methods for protein in cerebrospinal fluid the pyrogallol molybdate red complex had a sensitivity of 88.9% and a specificity of 90.5 and the cut-off point was less than or equal to 960mg / L and the bromocresol green method had a sensitivity of 66.7, a specificity of 85.7 and a cut-off point less than or equal to 700mg / L. The comparison between the ROC curves of the two methods studied was significant with p=0.138.
Conclusions: The modified ELISA method is better than the bromocresol green method for protein in terms of specificity and sensitivity and in methods for quantifying serum albumin both methods do not show significant differences and have lower specificity and sensitivity than methods for quantifying protein in cerebrospinal fluid. |
first_indexed | 2024-12-12T03:00:51Z |
format | Article |
id | doaj.art-036ce85f79da4bb099c17bfde0150ae4 |
institution | Directory Open Access Journal |
issn | 0864-0300 1561-3011 |
language | Spanish |
last_indexed | 2024-12-12T03:00:51Z |
publishDate | 2019-05-01 |
publisher | Centro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED) |
record_format | Article |
series | Revista Cubana de Investigaciones Biomédicas |
spelling | doaj.art-036ce85f79da4bb099c17bfde0150ae42022-12-22T00:40:38ZspaCentro Nacional de Información de Ciencias Médicas. Editorial de Ciencias Médicas (ECIMED)Revista Cubana de Investigaciones Biomédicas0864-03001561-30112019-05-01381119Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal FluidVanessa Pérez-del-Vallìn0José Alejandro Rodríguez-PérezAlejandro Mirabal-VielChristian Meijides-MejíasJairo Lumpuy-CastilloWilliam Castillo-GonzálezAlberto Juan Dorta-ContrerasLaboratorio Centrales de Lìquido Cefalorraquìdeo (LABCEL) Universidad de Ciencias Médicas de La Habana, Facultad Miguel Enrìquez.Introduction: Albumin is the protein that marks the passage of cerebrospinal fluid proteins into the serum. Materials and methods: Serum albumin was quantified by bromocresol green dye technique and by using the modified microalbuminuria method and for protein in cerebrospinal fluid, the pyrogallol molybdate red complex technique and the bromocresol green method were used. Results: Compared methods in serum, the modified ELISA method had a sensitivity of 100%, a specificity of 80% and the cut-off point was less than or equal to 58 g / L. In both fluids the bromocresol green method had a sensitivity of 72.7%, specificity of 60% and the cut-off point was greater than 34g / L. The areas under the ROC curves of the two methods did not show significant differences for p = 0.074. In the methods for protein in cerebrospinal fluid the pyrogallol molybdate red complex had a sensitivity of 88.9% and a specificity of 90.5 and the cut-off point was less than or equal to 960mg / L and the bromocresol green method had a sensitivity of 66.7, a specificity of 85.7 and a cut-off point less than or equal to 700mg / L. The comparison between the ROC curves of the two methods studied was significant with p=0.138. Conclusions: The modified ELISA method is better than the bromocresol green method for protein in terms of specificity and sensitivity and in methods for quantifying serum albumin both methods do not show significant differences and have lower specificity and sensitivity than methods for quantifying protein in cerebrospinal fluid.http://www.revibiomedica.sld.cu/index.php/ibi/article/view/106 |
spellingShingle | Vanessa Pérez-del-Vallìn José Alejandro Rodríguez-Pérez Alejandro Mirabal-Viel Christian Meijides-Mejías Jairo Lumpuy-Castillo William Castillo-González Alberto Juan Dorta-Contreras Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid Revista Cubana de Investigaciones Biomédicas |
title | Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid |
title_full | Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid |
title_fullStr | Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid |
title_full_unstemmed | Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid |
title_short | Comparison Of Methods For The Quantification Of Albumin In Serum And Total Protein In Cerebrospinal Fluid |
title_sort | comparison of methods for the quantification of albumin in serum and total protein in cerebrospinal fluid |
url | http://www.revibiomedica.sld.cu/index.php/ibi/article/view/106 |
work_keys_str_mv | AT vanessaperezdelvallin comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid AT josealejandrorodriguezperez comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid AT alejandromirabalviel comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid AT christianmeijidesmejias comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid AT jairolumpuycastillo comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid AT williamcastillogonzalez comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid AT albertojuandortacontreras comparisonofmethodsforthequantificationofalbumininserumandtotalproteinincerebrospinalfluid |