Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirements

The system-specific selection of aeroponic nutrient system components, specifically pumps, pipes, and tanks, is very important to improve system efficiency and minimize costs, as these components vary for different systems with different crop water requirements and design specifications. In this stu...

Full description

Bibliographic Details
Main Authors: Milon Chowdhury, Md. Shaha Nur Kabir, Hyeon-Tae Kim, Sun-Ok Chung
Format: Article
Language:English
Published: PAGEPress Publications 2020-06-01
Series:Journal of Agricultural Engineering
Subjects:
Online Access:https://www.agroengineering.org/index.php/jae/article/view/1028
_version_ 1829103760663642112
author Milon Chowdhury
Md. Shaha Nur Kabir
Hyeon-Tae Kim
Sun-Ok Chung
author_facet Milon Chowdhury
Md. Shaha Nur Kabir
Hyeon-Tae Kim
Sun-Ok Chung
author_sort Milon Chowdhury
collection DOAJ
description The system-specific selection of aeroponic nutrient system components, specifically pumps, pipes, and tanks, is very important to improve system efficiency and minimize costs, as these components vary for different systems with different crop water requirements and design specifications. In this study, methods were suggested for determining the most suitable sizes of pumps, pipes, and tanks based on the plant water consumption and irrigation interval targeted to improve the usual procedures to design an aeroponic nutrient management system, and applied to a case. Factors affecting the size calculation are discussed, and calculation methods were suggested based on basic hydraulic principles. A recycle-type aeroponic nutrient management system, cultivating 500 plants in 21 plant beds, was considered for a case study. Application of the size calculation methods in the case study showed that an irrigation pump with a 37 Lmin–1 flow rate at 900 kPa capacity and nutrient pumps with a 5 Lmin–1 flow rate at 40 kPa capacity with 19-mmdiameter pipes were required to deliver the mixed nutrients and supply stock solutions into the mixing tank, along with nutrient mixing, stock nutrients, and distilled water tanks of 750, 40, and 685 L, respectively. Calculation was demonstrated to show the variations in the sizing of the pumps, pipes, and tanks by number of plants. Validation tests were performed for the selected irrigation pump capacity, and the results showed that the Nash-Sutcliffe efficiency coefficient (NSE), coefficient of determination (R2), and root-mean-square error (RMSE) values were 0.410, 0.98, 0.109 Lmin–1 and 0.775, 0.99, 34.91 kPa for flow rate and pressure, respectively. The case study also showed that these sizing procedures increased the plant bed coverage efficiency of the irrigation pump by 33%, while increasing the nutrient mixing tank size by 133%. This study would provide useful information on the efficient sizing of pumps, pipes, and tanks for minimizing costs and maximizing crop production in aeroponic nutrient management systems.
first_indexed 2024-12-12T04:15:38Z
format Article
id doaj.art-036fd0c1fa264aceb71fdf8f0aa7e440
institution Directory Open Access Journal
issn 1974-7071
2239-6268
language English
last_indexed 2024-12-12T04:15:38Z
publishDate 2020-06-01
publisher PAGEPress Publications
record_format Article
series Journal of Agricultural Engineering
spelling doaj.art-036fd0c1fa264aceb71fdf8f0aa7e4402022-12-22T00:38:27ZengPAGEPress PublicationsJournal of Agricultural Engineering1974-70712239-62682020-06-0151210.4081/jae.2020.1028Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirementsMilon Chowdhury0Md. Shaha Nur Kabir1Hyeon-Tae Kim2Sun-Ok Chung3Department of Agricultural Machinery Engineering, Chungnam National University, Daejeon, Republic of Korea; Department of Smart Agriculture Systems, Chungnam National University, DaejeonDepartment of Agricultural and Industrial Engineering, Hajee Mohammad Danesh Science and Technology University, DinajpurDepartment of Biosystems Machinery Engineering, Gyeongsang National University, JinjuDepartment of Agricultural Machinery Engineering, Chungnam National University, Daejeon, Republic of Korea; Department of Smart Agriculture Systems, Chungnam National University, DaejeonThe system-specific selection of aeroponic nutrient system components, specifically pumps, pipes, and tanks, is very important to improve system efficiency and minimize costs, as these components vary for different systems with different crop water requirements and design specifications. In this study, methods were suggested for determining the most suitable sizes of pumps, pipes, and tanks based on the plant water consumption and irrigation interval targeted to improve the usual procedures to design an aeroponic nutrient management system, and applied to a case. Factors affecting the size calculation are discussed, and calculation methods were suggested based on basic hydraulic principles. A recycle-type aeroponic nutrient management system, cultivating 500 plants in 21 plant beds, was considered for a case study. Application of the size calculation methods in the case study showed that an irrigation pump with a 37 Lmin–1 flow rate at 900 kPa capacity and nutrient pumps with a 5 Lmin–1 flow rate at 40 kPa capacity with 19-mmdiameter pipes were required to deliver the mixed nutrients and supply stock solutions into the mixing tank, along with nutrient mixing, stock nutrients, and distilled water tanks of 750, 40, and 685 L, respectively. Calculation was demonstrated to show the variations in the sizing of the pumps, pipes, and tanks by number of plants. Validation tests were performed for the selected irrigation pump capacity, and the results showed that the Nash-Sutcliffe efficiency coefficient (NSE), coefficient of determination (R2), and root-mean-square error (RMSE) values were 0.410, 0.98, 0.109 Lmin–1 and 0.775, 0.99, 34.91 kPa for flow rate and pressure, respectively. The case study also showed that these sizing procedures increased the plant bed coverage efficiency of the irrigation pump by 33%, while increasing the nutrient mixing tank size by 133%. This study would provide useful information on the efficient sizing of pumps, pipes, and tanks for minimizing costs and maximizing crop production in aeroponic nutrient management systems.https://www.agroengineering.org/index.php/jae/article/view/1028Aeroponic crop cultivationnutrient managementirrigationsize selection.
spellingShingle Milon Chowdhury
Md. Shaha Nur Kabir
Hyeon-Tae Kim
Sun-Ok Chung
Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirements
Journal of Agricultural Engineering
Aeroponic crop cultivation
nutrient management
irrigation
size selection.
title Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirements
title_full Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirements
title_fullStr Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirements
title_full_unstemmed Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirements
title_short Method of pump, pipe, and tank selection for aeroponic nutrient management systems based on crop requirements
title_sort method of pump pipe and tank selection for aeroponic nutrient management systems based on crop requirements
topic Aeroponic crop cultivation
nutrient management
irrigation
size selection.
url https://www.agroengineering.org/index.php/jae/article/view/1028
work_keys_str_mv AT milonchowdhury methodofpumppipeandtankselectionforaeroponicnutrientmanagementsystemsbasedoncroprequirements
AT mdshahanurkabir methodofpumppipeandtankselectionforaeroponicnutrientmanagementsystemsbasedoncroprequirements
AT hyeontaekim methodofpumppipeandtankselectionforaeroponicnutrientmanagementsystemsbasedoncroprequirements
AT sunokchung methodofpumppipeandtankselectionforaeroponicnutrientmanagementsystemsbasedoncroprequirements