The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically

The mismatch between bony endplates (BEPs) and grafted bone (GB) triggers several complications biomechanically. However, no published study has identified whether this factor increases the risk of screw loosening by deteriorating the local stress levels. This study aimed to illustrate the biomechan...

Full description

Bibliographic Details
Main Authors: Jing-Chi Li, Tian-Hang Xie, Zhuang Zhang, Zhe-Tao Song, Yue-Ming Song, Jian-Cheng Zeng
Format: Article
Language:English
Published: Frontiers Media S.A. 2022-04-01
Series:Frontiers in Bioengineering and Biotechnology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fbioe.2022.862951/full
_version_ 1819045456142925824
author Jing-Chi Li
Tian-Hang Xie
Zhuang Zhang
Zhe-Tao Song
Yue-Ming Song
Jian-Cheng Zeng
author_facet Jing-Chi Li
Tian-Hang Xie
Zhuang Zhang
Zhe-Tao Song
Yue-Ming Song
Jian-Cheng Zeng
author_sort Jing-Chi Li
collection DOAJ
description The mismatch between bony endplates (BEPs) and grafted bone (GB) triggers several complications biomechanically. However, no published study has identified whether this factor increases the risk of screw loosening by deteriorating the local stress levels. This study aimed to illustrate the biomechanical effects of the mismatch between BEP and GB and the related risk of screw loosening. In this study, radiographic and demographic data of 56 patients treated by single segment oblique lumbar interbody fusion (OLIF) with anterior lateral single rod (ALSR) fixation were collected retrospectively, and the match sufficiency between BEP and GB was measured and presented as the grafted bony occupancy rate (GBOR). Data in patients with and without screw loosening were compared; regression analyses identified independent risk factors. OLIF with different GBORs was simulated in a previously constructed and validated lumbosacral model, and biomechanical indicators related to screw loosening were computed in surgical models. The radiographic review and numerical simulations showed that the coronal plane’s GBOR was significantly lower in screw loosening patients both in the cranial and caudal vertebral bodies; the decrease in the coronal plane’s GBOR has been proven to be an independent risk factor for screw loosening. In addition, numerical mechanical simulations showed that the poor match between BEP and GB will lead to stress concentration on both screws and bone-screw interfaces. Therefore, we can conclude that the mismatch between the BEP and GB will increase the risk of screw loosening by deteriorating local stress levels, and the increase in the GBOR by modifying the OLIF cage’s design may be an effective method to optimize the patient’s prognosis.
first_indexed 2024-12-21T10:28:51Z
format Article
id doaj.art-0494396d853e46e6a84a6712208a2a60
institution Directory Open Access Journal
issn 2296-4185
language English
last_indexed 2024-12-21T10:28:51Z
publishDate 2022-04-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Bioengineering and Biotechnology
spelling doaj.art-0494396d853e46e6a84a6712208a2a602022-12-21T19:07:15ZengFrontiers Media S.A.Frontiers in Bioengineering and Biotechnology2296-41852022-04-011010.3389/fbioe.2022.862951862951The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation BiomechanicallyJing-Chi Li0Tian-Hang Xie1Zhuang Zhang2Zhe-Tao Song3Yue-Ming Song4Jian-Cheng Zeng5Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, ChinaDepartment of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, ChinaDepartment of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, ChinaDepartment of Imaging, West China Hospital, Chengdu, ChinaDepartment of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, ChinaDepartment of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital/West China School of Medicine for Sichuan University, Chengdu, ChinaThe mismatch between bony endplates (BEPs) and grafted bone (GB) triggers several complications biomechanically. However, no published study has identified whether this factor increases the risk of screw loosening by deteriorating the local stress levels. This study aimed to illustrate the biomechanical effects of the mismatch between BEP and GB and the related risk of screw loosening. In this study, radiographic and demographic data of 56 patients treated by single segment oblique lumbar interbody fusion (OLIF) with anterior lateral single rod (ALSR) fixation were collected retrospectively, and the match sufficiency between BEP and GB was measured and presented as the grafted bony occupancy rate (GBOR). Data in patients with and without screw loosening were compared; regression analyses identified independent risk factors. OLIF with different GBORs was simulated in a previously constructed and validated lumbosacral model, and biomechanical indicators related to screw loosening were computed in surgical models. The radiographic review and numerical simulations showed that the coronal plane’s GBOR was significantly lower in screw loosening patients both in the cranial and caudal vertebral bodies; the decrease in the coronal plane’s GBOR has been proven to be an independent risk factor for screw loosening. In addition, numerical mechanical simulations showed that the poor match between BEP and GB will lead to stress concentration on both screws and bone-screw interfaces. Therefore, we can conclude that the mismatch between the BEP and GB will increase the risk of screw loosening by deteriorating local stress levels, and the increase in the GBOR by modifying the OLIF cage’s design may be an effective method to optimize the patient’s prognosis.https://www.frontiersin.org/articles/10.3389/fbioe.2022.862951/fulloblique lumbar interbody fusiongrafted bony occupancy ratescrew looseningbiomechanical deteriorationanterior lateral single rod fixation
spellingShingle Jing-Chi Li
Tian-Hang Xie
Zhuang Zhang
Zhe-Tao Song
Yue-Ming Song
Jian-Cheng Zeng
The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
Frontiers in Bioengineering and Biotechnology
oblique lumbar interbody fusion
grafted bony occupancy rate
screw loosening
biomechanical deterioration
anterior lateral single rod fixation
title The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_full The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_fullStr The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_full_unstemmed The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_short The Mismatch Between Bony Endplates and Grafted Bone Increases Screw Loosening Risk for OLIF Patients With ALSR Fixation Biomechanically
title_sort mismatch between bony endplates and grafted bone increases screw loosening risk for olif patients with alsr fixation biomechanically
topic oblique lumbar interbody fusion
grafted bony occupancy rate
screw loosening
biomechanical deterioration
anterior lateral single rod fixation
url https://www.frontiersin.org/articles/10.3389/fbioe.2022.862951/full
work_keys_str_mv AT jingchili themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT tianhangxie themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zhuangzhang themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zhetaosong themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT yuemingsong themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT jianchengzeng themismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT jingchili mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT tianhangxie mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zhuangzhang mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT zhetaosong mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT yuemingsong mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically
AT jianchengzeng mismatchbetweenbonyendplatesandgraftedboneincreasesscrewlooseningriskforolifpatientswithalsrfixationbiomechanically