Review on solving the inverse problem in EEG source analysis

<p>Abstract</p> <p>In this primer, we give a review of the inverse problem for EEG source localization. This is intended for the researchers new in the field to get insight in the state-of-the-art techniques used to find approximate solutions of the brain sources giving rise to a s...

Full description

Bibliographic Details
Main Authors: Fabri Simon G, Camilleri Kenneth P, Muscat Joseph, Cassar Tracey, Grech Roberta, Zervakis Michalis, Xanthopoulos Petros, Sakkalis Vangelis, Vanrumste Bart
Format: Article
Language:English
Published: BMC 2008-11-01
Series:Journal of NeuroEngineering and Rehabilitation
Online Access:http://www.jneuroengrehab.com/content/5/1/25
_version_ 1828499316947288064
author Fabri Simon G
Camilleri Kenneth P
Muscat Joseph
Cassar Tracey
Grech Roberta
Zervakis Michalis
Xanthopoulos Petros
Sakkalis Vangelis
Vanrumste Bart
author_facet Fabri Simon G
Camilleri Kenneth P
Muscat Joseph
Cassar Tracey
Grech Roberta
Zervakis Michalis
Xanthopoulos Petros
Sakkalis Vangelis
Vanrumste Bart
author_sort Fabri Simon G
collection DOAJ
description <p>Abstract</p> <p>In this primer, we give a review of the inverse problem for EEG source localization. This is intended for the researchers new in the field to get insight in the state-of-the-art techniques used to find approximate solutions of the brain sources giving rise to a scalp potential recording. Furthermore, a review of the performance results of the different techniques is provided to compare these different inverse solutions. The authors also include the results of a Monte-Carlo analysis which they performed to compare four non parametric algorithms and hence contribute to what is presently recorded in the literature. An extensive list of references to the work of other researchers is also provided.</p> <p>This paper starts off with a mathematical description of the inverse problem and proceeds to discuss the two main categories of methods which were developed to solve the EEG inverse problem, mainly the non parametric and parametric methods. The main difference between the two is to whether a fixed number of dipoles is assumed a priori or not. Various techniques falling within these categories are described including minimum norm estimates and their generalizations, LORETA, sLORETA, VARETA, S-MAP, ST-MAP, Backus-Gilbert, LAURA, Shrinking LORETA FOCUSS (SLF), SSLOFO and ALF for non parametric methods and beamforming techniques, BESA, subspace techniques such as MUSIC and methods derived from it, FINES, simulated annealing and computational intelligence algorithms for parametric methods. From a review of the performance of these techniques as documented in the literature, one could conclude that in most cases the LORETA solution gives satisfactory results. In situations involving clusters of dipoles, higher resolution algorithms such as MUSIC or FINES are however preferred. Imposing reliable biophysical and psychological constraints, as done by LAURA has given superior results. The Monte-Carlo analysis performed, comparing WMN, LORETA, sLORETA and SLF, for different noise levels and different simulated source depths has shown that for single source localization, regularized sLORETA gives the best solution in terms of both localization error and ghost sources. Furthermore the computationally intensive solution given by SLF was not found to give any additional benefits under such simulated conditions.</p>
first_indexed 2024-12-11T13:22:31Z
format Article
id doaj.art-05979809f05741469cc711902b832748
institution Directory Open Access Journal
issn 1743-0003
language English
last_indexed 2024-12-11T13:22:31Z
publishDate 2008-11-01
publisher BMC
record_format Article
series Journal of NeuroEngineering and Rehabilitation
spelling doaj.art-05979809f05741469cc711902b8327482022-12-22T01:05:44ZengBMCJournal of NeuroEngineering and Rehabilitation1743-00032008-11-01512510.1186/1743-0003-5-25Review on solving the inverse problem in EEG source analysisFabri Simon GCamilleri Kenneth PMuscat JosephCassar TraceyGrech RobertaZervakis MichalisXanthopoulos PetrosSakkalis VangelisVanrumste Bart<p>Abstract</p> <p>In this primer, we give a review of the inverse problem for EEG source localization. This is intended for the researchers new in the field to get insight in the state-of-the-art techniques used to find approximate solutions of the brain sources giving rise to a scalp potential recording. Furthermore, a review of the performance results of the different techniques is provided to compare these different inverse solutions. The authors also include the results of a Monte-Carlo analysis which they performed to compare four non parametric algorithms and hence contribute to what is presently recorded in the literature. An extensive list of references to the work of other researchers is also provided.</p> <p>This paper starts off with a mathematical description of the inverse problem and proceeds to discuss the two main categories of methods which were developed to solve the EEG inverse problem, mainly the non parametric and parametric methods. The main difference between the two is to whether a fixed number of dipoles is assumed a priori or not. Various techniques falling within these categories are described including minimum norm estimates and their generalizations, LORETA, sLORETA, VARETA, S-MAP, ST-MAP, Backus-Gilbert, LAURA, Shrinking LORETA FOCUSS (SLF), SSLOFO and ALF for non parametric methods and beamforming techniques, BESA, subspace techniques such as MUSIC and methods derived from it, FINES, simulated annealing and computational intelligence algorithms for parametric methods. From a review of the performance of these techniques as documented in the literature, one could conclude that in most cases the LORETA solution gives satisfactory results. In situations involving clusters of dipoles, higher resolution algorithms such as MUSIC or FINES are however preferred. Imposing reliable biophysical and psychological constraints, as done by LAURA has given superior results. The Monte-Carlo analysis performed, comparing WMN, LORETA, sLORETA and SLF, for different noise levels and different simulated source depths has shown that for single source localization, regularized sLORETA gives the best solution in terms of both localization error and ghost sources. Furthermore the computationally intensive solution given by SLF was not found to give any additional benefits under such simulated conditions.</p>http://www.jneuroengrehab.com/content/5/1/25
spellingShingle Fabri Simon G
Camilleri Kenneth P
Muscat Joseph
Cassar Tracey
Grech Roberta
Zervakis Michalis
Xanthopoulos Petros
Sakkalis Vangelis
Vanrumste Bart
Review on solving the inverse problem in EEG source analysis
Journal of NeuroEngineering and Rehabilitation
title Review on solving the inverse problem in EEG source analysis
title_full Review on solving the inverse problem in EEG source analysis
title_fullStr Review on solving the inverse problem in EEG source analysis
title_full_unstemmed Review on solving the inverse problem in EEG source analysis
title_short Review on solving the inverse problem in EEG source analysis
title_sort review on solving the inverse problem in eeg source analysis
url http://www.jneuroengrehab.com/content/5/1/25
work_keys_str_mv AT fabrisimong reviewonsolvingtheinverseproblemineegsourceanalysis
AT camillerikennethp reviewonsolvingtheinverseproblemineegsourceanalysis
AT muscatjoseph reviewonsolvingtheinverseproblemineegsourceanalysis
AT cassartracey reviewonsolvingtheinverseproblemineegsourceanalysis
AT grechroberta reviewonsolvingtheinverseproblemineegsourceanalysis
AT zervakismichalis reviewonsolvingtheinverseproblemineegsourceanalysis
AT xanthopoulospetros reviewonsolvingtheinverseproblemineegsourceanalysis
AT sakkalisvangelis reviewonsolvingtheinverseproblemineegsourceanalysis
AT vanrumstebart reviewonsolvingtheinverseproblemineegsourceanalysis