A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System Substation

With the integration of Distributed Energy Resources (DERs) into the distribution networks, the Active Distribution Network Management is becoming quite challenging. The DERs are integrated into the distribution networks through distribution substations. For achieving greater control and ease of ope...

Full description

Bibliographic Details
Main Authors: Taha Selim Ustun, Mohd Asim Aftab, Ikbal Ali, S. M. Suhail Hussain
Format: Article
Language:English
Published: IEEE 2019-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8817969/
_version_ 1819174674853003264
author Taha Selim Ustun
Mohd Asim Aftab
Ikbal Ali
S. M. Suhail Hussain
author_facet Taha Selim Ustun
Mohd Asim Aftab
Ikbal Ali
S. M. Suhail Hussain
author_sort Taha Selim Ustun
collection DOAJ
description With the integration of Distributed Energy Resources (DERs) into the distribution networks, the Active Distribution Network Management is becoming quite challenging. The DERs are integrated into the distribution networks through distribution substations. For achieving greater control and ease of operation substations are being automated by employing substation communication network based on standardized communication. IEC 61850 standard has emerged as the most popular standard due to its object-oriented modeling and interoperability features. To ensure smooth and efficient operation of substation automation system, the performance requirements for intra substation communication needs to be evaluated. This paper presents modelling of data traffic in the substation according to IEC 61850 and provides validation through simulation as well as through experimental setup. In the experimental setup, a real bay is replicated in the laboratory for performance validation. The scheme has been validated for VLAN and priority tagging implementation with the obtained simulation results.
first_indexed 2024-12-22T20:42:44Z
format Article
id doaj.art-05bb87568f0a42faa41c0ec71e95710f
institution Directory Open Access Journal
issn 2169-3536
language English
last_indexed 2024-12-22T20:42:44Z
publishDate 2019-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj.art-05bb87568f0a42faa41c0ec71e95710f2022-12-21T18:13:18ZengIEEEIEEE Access2169-35362019-01-01712389312390210.1109/ACCESS.2019.29379718817969A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System SubstationTaha Selim Ustun0https://orcid.org/0000-0002-2413-8421Mohd Asim Aftab1https://orcid.org/0000-0002-1546-8349Ikbal Ali2S. M. Suhail Hussain3https://orcid.org/0000-0002-7779-8140Fukushima Renewable Energy Institute, AIST (FREA), Koriyama, JapanDepartment of Electrical Engineering, Jamia Millia Islamia (a central University), New Delhi, IndiaDepartment of Electrical Engineering, Jamia Millia Islamia (a central University), New Delhi, IndiaFukushima Renewable Energy Institute, AIST (FREA), Koriyama, JapanWith the integration of Distributed Energy Resources (DERs) into the distribution networks, the Active Distribution Network Management is becoming quite challenging. The DERs are integrated into the distribution networks through distribution substations. For achieving greater control and ease of operation substations are being automated by employing substation communication network based on standardized communication. IEC 61850 standard has emerged as the most popular standard due to its object-oriented modeling and interoperability features. To ensure smooth and efficient operation of substation automation system, the performance requirements for intra substation communication needs to be evaluated. This paper presents modelling of data traffic in the substation according to IEC 61850 and provides validation through simulation as well as through experimental setup. In the experimental setup, a real bay is replicated in the laboratory for performance validation. The scheme has been validated for VLAN and priority tagging implementation with the obtained simulation results.https://ieeexplore.ieee.org/document/8817969/Active distribution system (ADS)IEC 61850substation communication network (SCN)GOOSE
spellingShingle Taha Selim Ustun
Mohd Asim Aftab
Ikbal Ali
S. M. Suhail Hussain
A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System Substation
IEEE Access
Active distribution system (ADS)
IEC 61850
substation communication network (SCN)
GOOSE
title A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System Substation
title_full A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System Substation
title_fullStr A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System Substation
title_full_unstemmed A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System Substation
title_short A Novel Scheme for Performance Evaluation of an IEC 61850-Based Active Distribution System Substation
title_sort novel scheme for performance evaluation of an iec 61850 based active distribution system substation
topic Active distribution system (ADS)
IEC 61850
substation communication network (SCN)
GOOSE
url https://ieeexplore.ieee.org/document/8817969/
work_keys_str_mv AT tahaselimustun anovelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation
AT mohdasimaftab anovelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation
AT ikbalali anovelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation
AT smsuhailhussain anovelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation
AT tahaselimustun novelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation
AT mohdasimaftab novelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation
AT ikbalali novelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation
AT smsuhailhussain novelschemeforperformanceevaluationofaniec61850basedactivedistributionsystemsubstation