BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATOR

The relevance of the paper is determined by the need to improve energy efficiency parameters of power converting devices for the needs of alternative energy, in particular for a wind generator. One of the difficulties of converting wind energy is the low level of energy efficiency of this process. D...

Full description

Bibliographic Details
Main Authors: Sergey G. Mikhalchenko, Gennady Ya. Mikhalchenko, Sergey M. Semenov, Pavel S. Meshcheryakov, Natalya A. Voronina, Anatoliy M. Ziuzev
Format: Article
Language:Russian
Published: Tomsk Polytechnic University 2020-12-01
Series:Известия Томского политехнического университета: Инжиниринг георесурсов
Subjects:
Online Access:http://izvestiya.tpu.ru/archive/article/view/2957/2377
_version_ 1818460269371719680
author Sergey G. Mikhalchenko
Gennady Ya. Mikhalchenko
Sergey M. Semenov
Pavel S. Meshcheryakov
Natalya A. Voronina
Anatoliy M. Ziuzev
author_facet Sergey G. Mikhalchenko
Gennady Ya. Mikhalchenko
Sergey M. Semenov
Pavel S. Meshcheryakov
Natalya A. Voronina
Anatoliy M. Ziuzev
author_sort Sergey G. Mikhalchenko
collection DOAJ
description The relevance of the paper is determined by the need to improve energy efficiency parameters of power converting devices for the needs of alternative energy, in particular for a wind generator. One of the difficulties of converting wind energy is the low level of energy efficiency of this process. Due to the variable value of the rotational speed of the blades of the wind turbine in a certain time interval, the parameters of the received energy are variable, therefore, the settings of the secondary converters of electric energy must correspond to the time intervals for generating the signal. Improving the functioning of alternative power sources is possible through the use of multi-frequency stabilization modes of the converter. The article considers a model of a pulse-modulation step-down voltage converter based on pulse‑frequency modulation. The authors have studied and proposed the methods for changing the width of the working zone of a single-frequency stabilization mode. The main aim of the study is to analyze the changing modes of the secondary voltage converter of a wind generator and to develop approaches to the study of bifurcation phenomena that occur in a converter with pulse‑frequency modulation by constructing a mathematical model and numerically-analytical modeling of a buck voltage converter to improve the reliability of the system under consideration. Methods: study of literature on standard energy conversion schemes in wind turbines with an intermediate DC link; mathematical modeling and conducting numerical experiments to change the operational parameters of a buck converter with pulse‑frequency modulation to identify bifurcation in it; construction of bifurcation diagrams for various parameters of the transducer in order to increase the reliability of operation. The results. The authors obtained the mathematical models and numerical-analytical technique for constructing and identifying dynamic modes of a voltage converter with pulse‑frequency modulation acting as a DC link of a wind generator set and constructed the bifurcation diagrams for voltage stabilization at different parameters of the control system. The simultaneous presence of single-frequency and burst-packed modes was shown, bifurcation of period division was identified; the influence of the system parameters on the operating modes was studied, and methods for changing the width of the working zone of the single-frequency stabilization mode were proposed.
first_indexed 2024-12-14T23:27:34Z
format Article
id doaj.art-06461795828748c9b3e747882bdb4534
institution Directory Open Access Journal
issn 2500-1019
2413-1830
language Russian
last_indexed 2024-12-14T23:27:34Z
publishDate 2020-12-01
publisher Tomsk Polytechnic University
record_format Article
series Известия Томского политехнического университета: Инжиниринг георесурсов
spelling doaj.art-06461795828748c9b3e747882bdb45342022-12-21T22:43:46ZrusTomsk Polytechnic UniversityИзвестия Томского политехнического университета: Инжиниринг георесурсов2500-10192413-18302020-12-013311221522510.18799/24131830/2020/12/2957BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATORSergey G. Mikhalchenko0Gennady Ya. Mikhalchenko1Sergey M. Semenov2Pavel S. Meshcheryakov3Natalya A. Voronina4Anatoliy M. Ziuzev5Tomsk State University of Control Systems and RadioelectronicsTomsk State University of Control Systems and RadioelectronicsNational Research Tomsk Polytechnic UniversityTomsk State University of Control Systems and RadioelectronicsNational Research Tomsk Polytechnic UniversityUral Federal UniversityThe relevance of the paper is determined by the need to improve energy efficiency parameters of power converting devices for the needs of alternative energy, in particular for a wind generator. One of the difficulties of converting wind energy is the low level of energy efficiency of this process. Due to the variable value of the rotational speed of the blades of the wind turbine in a certain time interval, the parameters of the received energy are variable, therefore, the settings of the secondary converters of electric energy must correspond to the time intervals for generating the signal. Improving the functioning of alternative power sources is possible through the use of multi-frequency stabilization modes of the converter. The article considers a model of a pulse-modulation step-down voltage converter based on pulse‑frequency modulation. The authors have studied and proposed the methods for changing the width of the working zone of a single-frequency stabilization mode. The main aim of the study is to analyze the changing modes of the secondary voltage converter of a wind generator and to develop approaches to the study of bifurcation phenomena that occur in a converter with pulse‑frequency modulation by constructing a mathematical model and numerically-analytical modeling of a buck voltage converter to improve the reliability of the system under consideration. Methods: study of literature on standard energy conversion schemes in wind turbines with an intermediate DC link; mathematical modeling and conducting numerical experiments to change the operational parameters of a buck converter with pulse‑frequency modulation to identify bifurcation in it; construction of bifurcation diagrams for various parameters of the transducer in order to increase the reliability of operation. The results. The authors obtained the mathematical models and numerical-analytical technique for constructing and identifying dynamic modes of a voltage converter with pulse‑frequency modulation acting as a DC link of a wind generator set and constructed the bifurcation diagrams for voltage stabilization at different parameters of the control system. The simultaneous presence of single-frequency and burst-packed modes was shown, bifurcation of period division was identified; the influence of the system parameters on the operating modes was studied, and methods for changing the width of the working zone of the single-frequency stabilization mode were proposed.http://izvestiya.tpu.ru/archive/article/view/2957/2377wind generationbuck voltage converterpulse-frequency modulationswitching functionbifurcation diagramsingle-frequency mode of stabilization
spellingShingle Sergey G. Mikhalchenko
Gennady Ya. Mikhalchenko
Sergey M. Semenov
Pavel S. Meshcheryakov
Natalya A. Voronina
Anatoliy M. Ziuzev
BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATOR
Известия Томского политехнического университета: Инжиниринг георесурсов
wind generation
buck voltage converter
pulse-frequency modulation
switching function
bifurcation diagram
single-frequency mode of stabilization
title BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATOR
title_full BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATOR
title_fullStr BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATOR
title_full_unstemmed BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATOR
title_short BIFURCATION PHENOMENA IN VOLTAGE CONVERTER WITH FREQUENCY-PULSE CONTROL FOR A WIND GENERATOR
title_sort bifurcation phenomena in voltage converter with frequency pulse control for a wind generator
topic wind generation
buck voltage converter
pulse-frequency modulation
switching function
bifurcation diagram
single-frequency mode of stabilization
url http://izvestiya.tpu.ru/archive/article/view/2957/2377
work_keys_str_mv AT sergeygmikhalchenko bifurcationphenomenainvoltageconverterwithfrequencypulsecontrolforawindgenerator
AT gennadyyamikhalchenko bifurcationphenomenainvoltageconverterwithfrequencypulsecontrolforawindgenerator
AT sergeymsemenov bifurcationphenomenainvoltageconverterwithfrequencypulsecontrolforawindgenerator
AT pavelsmeshcheryakov bifurcationphenomenainvoltageconverterwithfrequencypulsecontrolforawindgenerator
AT natalyaavoronina bifurcationphenomenainvoltageconverterwithfrequencypulsecontrolforawindgenerator
AT anatoliymziuzev bifurcationphenomenainvoltageconverterwithfrequencypulsecontrolforawindgenerator