The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip
Background: Total hip arthroplasty (THA) is an effective operation for patients with hip osteoarthritis; however, patients with hip dysplasia present a particular challenge. Our novel study examined the effect of robot-assisted THA in patients with hip dysplasia. Methods: We retrospectively reviewed...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-12-01
|
Series: | Arthroplasty Today |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2352344120301412 |
_version_ | 1818870764788514816 |
---|---|
author | Jonathan M. Vigdorchik, MD Abhinav K. Sharma, BS Vinay K. Aggarwal, MD Kaitlin M. Carroll, BS Seth A. Jerabek, MD |
author_facet | Jonathan M. Vigdorchik, MD Abhinav K. Sharma, BS Vinay K. Aggarwal, MD Kaitlin M. Carroll, BS Seth A. Jerabek, MD |
author_sort | Jonathan M. Vigdorchik, MD |
collection | DOAJ |
description | Background: Total hip arthroplasty (THA) is an effective operation for patients with hip osteoarthritis; however, patients with hip dysplasia present a particular challenge. Our novel study examined the effect of robot-assisted THA in patients with hip dysplasia. Methods: We retrospectively reviewed patients with developmental dysplasia of the hip undergoing primary THA using robotic arm assistance at 2 institutions from January 2010 to January 2017. Patients undergoing revision arthroplasty were excluded. Preoperatively, all patients underwent a computed tomography scan so that 3-dimensional templating could be performed. Hip range of motion (ROM) and clinical leg length discrepancy were recorded preoperatively. Two independent observers calculated Crowe and Hartofilakidis grades for each operative hip. At the final follow-up, hip ROM, postoperative complications, and modified Harris Hip scores were obtained. Results: Seventy-nine patients underwent THA because of degenerative joint disease in the setting of developmental dysplasia of the hip. There were 56 females and 23 males with a mean age of 45 years (range: 26-64 years). We found that components were placed according to the preoperative plan, that there was an improvement in the modified Harris hip score from 29 to 86 (P < .001), an improvement in the hip ROM (flexion improvement from 66° to 91°, P < .0001), and a correction of leg length discrepancy (17.1 vs 4 mm, P < .0002). There were no complications during the short-term interim follow-up (mean: 3.1 years). Conclusions: Robot-assisted THA can be a useful method to ensure adequate component positioning and excellent outcomes in patients with hip dysplasia. Level of Evidence: Level III, Retrospective |
first_indexed | 2024-12-19T12:12:13Z |
format | Article |
id | doaj.art-06a6924a192f48c4a7b160e642d247f1 |
institution | Directory Open Access Journal |
issn | 2352-3441 |
language | English |
last_indexed | 2024-12-19T12:12:13Z |
publishDate | 2020-12-01 |
publisher | Elsevier |
record_format | Article |
series | Arthroplasty Today |
spelling | doaj.art-06a6924a192f48c4a7b160e642d247f12022-12-21T20:22:08ZengElsevierArthroplasty Today2352-34412020-12-0164770776The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the HipJonathan M. Vigdorchik, MD0Abhinav K. Sharma, BS1Vinay K. Aggarwal, MD2Kaitlin M. Carroll, BS3Seth A. Jerabek, MD4Department of Orthopedic Surgery, Hospital for Special Surgery, Adult Reconstruction and Joint Replacement Service, New York, NY, USA; Corresponding author. 535 E 70th Street, New York, NY 10021, USA. Tel.: +1 212 606 1992.Department of Orthopedic Surgery, Hospital for Special Surgery, Adult Reconstruction and Joint Replacement Service, New York, NY, USADepartment of Orthopedic Surgery, NYU Langone Health, Division of Adult Reconstruction, New York, NY, USADepartment of Orthopedic Surgery, Hospital for Special Surgery, Adult Reconstruction and Joint Replacement Service, New York, NY, USADepartment of Orthopedic Surgery, Hospital for Special Surgery, Adult Reconstruction and Joint Replacement Service, New York, NY, USABackground: Total hip arthroplasty (THA) is an effective operation for patients with hip osteoarthritis; however, patients with hip dysplasia present a particular challenge. Our novel study examined the effect of robot-assisted THA in patients with hip dysplasia. Methods: We retrospectively reviewed patients with developmental dysplasia of the hip undergoing primary THA using robotic arm assistance at 2 institutions from January 2010 to January 2017. Patients undergoing revision arthroplasty were excluded. Preoperatively, all patients underwent a computed tomography scan so that 3-dimensional templating could be performed. Hip range of motion (ROM) and clinical leg length discrepancy were recorded preoperatively. Two independent observers calculated Crowe and Hartofilakidis grades for each operative hip. At the final follow-up, hip ROM, postoperative complications, and modified Harris Hip scores were obtained. Results: Seventy-nine patients underwent THA because of degenerative joint disease in the setting of developmental dysplasia of the hip. There were 56 females and 23 males with a mean age of 45 years (range: 26-64 years). We found that components were placed according to the preoperative plan, that there was an improvement in the modified Harris hip score from 29 to 86 (P < .001), an improvement in the hip ROM (flexion improvement from 66° to 91°, P < .0001), and a correction of leg length discrepancy (17.1 vs 4 mm, P < .0002). There were no complications during the short-term interim follow-up (mean: 3.1 years). Conclusions: Robot-assisted THA can be a useful method to ensure adequate component positioning and excellent outcomes in patients with hip dysplasia. Level of Evidence: Level III, Retrospectivehttp://www.sciencedirect.com/science/article/pii/S2352344120301412Robot assistedTotal hip arthroplastyDysplasiaComponent positioning |
spellingShingle | Jonathan M. Vigdorchik, MD Abhinav K. Sharma, BS Vinay K. Aggarwal, MD Kaitlin M. Carroll, BS Seth A. Jerabek, MD The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip Arthroplasty Today Robot assisted Total hip arthroplasty Dysplasia Component positioning |
title | The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip |
title_full | The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip |
title_fullStr | The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip |
title_full_unstemmed | The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip |
title_short | The Use of Robotic-Assisted Total Hip Arthroplasty in Developmental Dysplasia of the Hip |
title_sort | use of robotic assisted total hip arthroplasty in developmental dysplasia of the hip |
topic | Robot assisted Total hip arthroplasty Dysplasia Component positioning |
url | http://www.sciencedirect.com/science/article/pii/S2352344120301412 |
work_keys_str_mv | AT jonathanmvigdorchikmd theuseofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT abhinavksharmabs theuseofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT vinaykaggarwalmd theuseofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT kaitlinmcarrollbs theuseofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT sethajerabekmd theuseofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT jonathanmvigdorchikmd useofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT abhinavksharmabs useofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT vinaykaggarwalmd useofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT kaitlinmcarrollbs useofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip AT sethajerabekmd useofroboticassistedtotalhiparthroplastyindevelopmentaldysplasiaofthehip |