A Review on Direct Digital Conversion Techniques for Biomedical Signal Acquisition
Biomedical signals such as Electrocardiogram (ECG), Electroencephalogram (EEG) and photoplethysmography (PPG) are recorded routinely to provide helpful information for early diagnosis of disease. Low power consumption is very important to allow long-term ambulatory monitoring with battery-powered sy...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-06-01
|
Series: | Electronics |
Subjects: | |
Online Access: | https://www.mdpi.com/2079-9292/12/12/2676 |
_version_ | 1797595080278671360 |
---|---|
author | Yizhao Zhou Shuang Song Shiwei Wang Yalong Wan Tian Yang Xiaopeng Yu Menglian Zhao |
author_facet | Yizhao Zhou Shuang Song Shiwei Wang Yalong Wan Tian Yang Xiaopeng Yu Menglian Zhao |
author_sort | Yizhao Zhou |
collection | DOAJ |
description | Biomedical signals such as Electrocardiogram (ECG), Electroencephalogram (EEG) and photoplethysmography (PPG) are recorded routinely to provide helpful information for early diagnosis of disease. Low power consumption is very important to allow long-term ambulatory monitoring with battery-powered systems. A direct digital conversion (DDC) technique has been proposed in recent years, which employs preamplifier and data converters, reducing the complexity of the readout chain and thus its power consumption. This paper provides a review on DDC for biopotential signals and bio-optical signal acquisition. The state-of-the-art DDC-based readout architectures together with circuit implementations are provided. |
first_indexed | 2024-03-11T02:32:21Z |
format | Article |
id | doaj.art-06ef3e532c4c4db59b63a4dcf7351479 |
institution | Directory Open Access Journal |
issn | 2079-9292 |
language | English |
last_indexed | 2024-03-11T02:32:21Z |
publishDate | 2023-06-01 |
publisher | MDPI AG |
record_format | Article |
series | Electronics |
spelling | doaj.art-06ef3e532c4c4db59b63a4dcf73514792023-11-18T10:09:04ZengMDPI AGElectronics2079-92922023-06-011212267610.3390/electronics12122676A Review on Direct Digital Conversion Techniques for Biomedical Signal AcquisitionYizhao Zhou0Shuang Song1Shiwei Wang2Yalong Wan3Tian Yang4Xiaopeng Yu5Menglian Zhao6College of Information Science and Electronics Engineering, Zhejiang University, Hangzhou 310027, ChinaSchool of Micro-Nanoelectronics, Zhejiang University, Hangzhou 310027, ChinaInstitute for Integrated Micro & Nano Systems, School of Engineering, University of Edinburgh, Edinburgh EH8 9JU, UKSchool of Micro-Nanoelectronics, Zhejiang University, Hangzhou 310027, ChinaSchool of Micro-Nanoelectronics, Zhejiang University, Hangzhou 310027, ChinaSchool of Micro-Nanoelectronics, Zhejiang University, Hangzhou 310027, ChinaCollege of Information Science and Electronics Engineering, Zhejiang University, Hangzhou 310027, ChinaBiomedical signals such as Electrocardiogram (ECG), Electroencephalogram (EEG) and photoplethysmography (PPG) are recorded routinely to provide helpful information for early diagnosis of disease. Low power consumption is very important to allow long-term ambulatory monitoring with battery-powered systems. A direct digital conversion (DDC) technique has been proposed in recent years, which employs preamplifier and data converters, reducing the complexity of the readout chain and thus its power consumption. This paper provides a review on DDC for biopotential signals and bio-optical signal acquisition. The state-of-the-art DDC-based readout architectures together with circuit implementations are provided.https://www.mdpi.com/2079-9292/12/12/2676biomedical signalelectrocardiogramelectroencephalogramphotoplethysmographydirect digital conversion |
spellingShingle | Yizhao Zhou Shuang Song Shiwei Wang Yalong Wan Tian Yang Xiaopeng Yu Menglian Zhao A Review on Direct Digital Conversion Techniques for Biomedical Signal Acquisition Electronics biomedical signal electrocardiogram electroencephalogram photoplethysmography direct digital conversion |
title | A Review on Direct Digital Conversion Techniques for Biomedical Signal Acquisition |
title_full | A Review on Direct Digital Conversion Techniques for Biomedical Signal Acquisition |
title_fullStr | A Review on Direct Digital Conversion Techniques for Biomedical Signal Acquisition |
title_full_unstemmed | A Review on Direct Digital Conversion Techniques for Biomedical Signal Acquisition |
title_short | A Review on Direct Digital Conversion Techniques for Biomedical Signal Acquisition |
title_sort | review on direct digital conversion techniques for biomedical signal acquisition |
topic | biomedical signal electrocardiogram electroencephalogram photoplethysmography direct digital conversion |
url | https://www.mdpi.com/2079-9292/12/12/2676 |
work_keys_str_mv | AT yizhaozhou areviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT shuangsong areviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT shiweiwang areviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT yalongwan areviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT tianyang areviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT xiaopengyu areviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT menglianzhao areviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT yizhaozhou reviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT shuangsong reviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT shiweiwang reviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT yalongwan reviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT tianyang reviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT xiaopengyu reviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition AT menglianzhao reviewondirectdigitalconversiontechniquesforbiomedicalsignalacquisition |