Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis

IntroductionThe use of volumetric modulated arc therapy (VMAT) with flattening-filter-free (FFF) beams is becoming more prevalent in lung cancer stereotactic body radiotherapy (SBRT). The aim in this study was to assess the impact of dosimetric and radiobiological differences between FFF and flatten...

Full description

Bibliographic Details
Main Authors: Junxiang Wu, Hongchang Song, Jie Li, Bin Tang, Fan Wu
Format: Article
Language:English
Published: Frontiers Media S.A. 2023-01-01
Series:Frontiers in Oncology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fonc.2023.1108142/full
_version_ 1797944736892321792
author Junxiang Wu
Hongchang Song
Jie Li
Bin Tang
Fan Wu
author_facet Junxiang Wu
Hongchang Song
Jie Li
Bin Tang
Fan Wu
author_sort Junxiang Wu
collection DOAJ
description IntroductionThe use of volumetric modulated arc therapy (VMAT) with flattening-filter-free (FFF) beams is becoming more prevalent in lung cancer stereotactic body radiotherapy (SBRT). The aim in this study was to assess the impact of dosimetric and radiobiological differences between FFF and flattening filter (FF) beams for lung SBRT based on the target volume.MethodsA total of 198 lung stereotactic body radiation therapy treatment plans with FFF beams and FF beams were retrospectively selected for this study. For all plans, the prescribed dose was 50 Gy/5 fractions, and the dose volume histogram (DVH) for the target and organs at risk (OAR) and the normal tissue complication probability (NTCP) of the lung were recorded and compared. Moreover, monitor units (MUs), the beam on-time and the treatment time were evaluated.ResultsThe study was performed following the Radiation Therapy Oncology Group (RTOG) 0813 and 0915 protocols. No significant differences in D90, coverage rate (CR) or conformity index (CI) of the target were observed between FFF beams and FF beams (p>0.05). The D2, R50% and gradient index (GI) for the target improved with FFF beams compared with FF beams (p<0.05). FFF beams also significantly reduced the dose for the lung, heart, spinal cord, esophagus and NTCP of the lung (p<0.05), compared with FF beams. However, there was no significant difference in sparing of the trachea (p>0.05). The mean MUs, beam on-time and treatment time were 1871 ± 278 MUs, 3.2 ± 0.2 min and 3.9 ± 0.3 min for FFF beams, and 1890 ± 260 MUs, 4.2 ± 0.3 min and 4.8 ± 0.4 min for FF beams, respectively.DiscussionThe FFF beam technique for lung SBRT with VMAT results in a better dose fall-off, better dose-sparing of OAR, lower NTCP of the lung and a shorter beam on-time compared with the FF beam technique. Additionally, the improvement in target and OAR-sparing for FFF beams was increased with increasing target volume.
first_indexed 2024-04-10T20:43:18Z
format Article
id doaj.art-0728610746324b499bfaff60cafeef92
institution Directory Open Access Journal
issn 2234-943X
language English
last_indexed 2024-04-10T20:43:18Z
publishDate 2023-01-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Oncology
spelling doaj.art-0728610746324b499bfaff60cafeef922023-01-24T11:59:19ZengFrontiers Media S.A.Frontiers in Oncology2234-943X2023-01-011310.3389/fonc.2023.11081421108142Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysisJunxiang Wu0Hongchang Song1Jie Li2Bin Tang3Fan Wu4Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, ChinaDepartment of Oncology, Xichang People’s Hospital, Xichang, ChinaRadiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, ChinaRadiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, ChinaRadiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, ChinaIntroductionThe use of volumetric modulated arc therapy (VMAT) with flattening-filter-free (FFF) beams is becoming more prevalent in lung cancer stereotactic body radiotherapy (SBRT). The aim in this study was to assess the impact of dosimetric and radiobiological differences between FFF and flattening filter (FF) beams for lung SBRT based on the target volume.MethodsA total of 198 lung stereotactic body radiation therapy treatment plans with FFF beams and FF beams were retrospectively selected for this study. For all plans, the prescribed dose was 50 Gy/5 fractions, and the dose volume histogram (DVH) for the target and organs at risk (OAR) and the normal tissue complication probability (NTCP) of the lung were recorded and compared. Moreover, monitor units (MUs), the beam on-time and the treatment time were evaluated.ResultsThe study was performed following the Radiation Therapy Oncology Group (RTOG) 0813 and 0915 protocols. No significant differences in D90, coverage rate (CR) or conformity index (CI) of the target were observed between FFF beams and FF beams (p>0.05). The D2, R50% and gradient index (GI) for the target improved with FFF beams compared with FF beams (p<0.05). FFF beams also significantly reduced the dose for the lung, heart, spinal cord, esophagus and NTCP of the lung (p<0.05), compared with FF beams. However, there was no significant difference in sparing of the trachea (p>0.05). The mean MUs, beam on-time and treatment time were 1871 ± 278 MUs, 3.2 ± 0.2 min and 3.9 ± 0.3 min for FFF beams, and 1890 ± 260 MUs, 4.2 ± 0.3 min and 4.8 ± 0.4 min for FF beams, respectively.DiscussionThe FFF beam technique for lung SBRT with VMAT results in a better dose fall-off, better dose-sparing of OAR, lower NTCP of the lung and a shorter beam on-time compared with the FF beam technique. Additionally, the improvement in target and OAR-sparing for FFF beams was increased with increasing target volume.https://www.frontiersin.org/articles/10.3389/fonc.2023.1108142/fullSBRTlung cancerFFF beamsVMATNTCP
spellingShingle Junxiang Wu
Hongchang Song
Jie Li
Bin Tang
Fan Wu
Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis
Frontiers in Oncology
SBRT
lung cancer
FFF beams
VMAT
NTCP
title Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis
title_full Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis
title_fullStr Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis
title_full_unstemmed Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis
title_short Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis
title_sort evaluation of flattening filter free and flattening filter dosimetric and radiobiological criteria for lung sbrt a volume based analysis
topic SBRT
lung cancer
FFF beams
VMAT
NTCP
url https://www.frontiersin.org/articles/10.3389/fonc.2023.1108142/full
work_keys_str_mv AT junxiangwu evaluationofflatteningfilterfreeandflatteningfilterdosimetricandradiobiologicalcriteriaforlungsbrtavolumebasedanalysis
AT hongchangsong evaluationofflatteningfilterfreeandflatteningfilterdosimetricandradiobiologicalcriteriaforlungsbrtavolumebasedanalysis
AT jieli evaluationofflatteningfilterfreeandflatteningfilterdosimetricandradiobiologicalcriteriaforlungsbrtavolumebasedanalysis
AT bintang evaluationofflatteningfilterfreeandflatteningfilterdosimetricandradiobiologicalcriteriaforlungsbrtavolumebasedanalysis
AT fanwu evaluationofflatteningfilterfreeandflatteningfilterdosimetricandradiobiologicalcriteriaforlungsbrtavolumebasedanalysis