Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation?
The analysis of immunosuppressive drugs allows the physician to monitor, and eventually correct, immunosuppressive therapy. The panel of molecules under evaluation includes cyclosporine A (CsA), tacrolimus, sirolimus, and everolimus. Initially, assays were performed by immunometric methods, but in t...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-04-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/12/7/3695 |
_version_ | 1797440240285122560 |
---|---|
author | Chiara Fania Marco Bagnati Marina Albertario Carlotta Ferraris Marta Lamonaca Umberto Dianzani |
author_facet | Chiara Fania Marco Bagnati Marina Albertario Carlotta Ferraris Marta Lamonaca Umberto Dianzani |
author_sort | Chiara Fania |
collection | DOAJ |
description | The analysis of immunosuppressive drugs allows the physician to monitor, and eventually correct, immunosuppressive therapy. The panel of molecules under evaluation includes cyclosporine A (CsA), tacrolimus, sirolimus, and everolimus. Initially, assays were performed by immunometric methods, but in the past few years this methodology has been largely superseded by a more accurate and specific technique, liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), which is now considered the “gold standard” for immunosuppressant analysis. Both LC-MS/MS and often also immunoassays require a preanalytical manual sample preparation, which involves time-consuming sequential operations whose traceability is often hampered and adds up to the probability of gross errors. The aim of this work was to compare an “open” LC-MS/MS with a fully automated system, consisting of LC instrumentation combined with a triple quadrupole MS, named Thermo Scientific<sup>TM</sup> Cascadion<sup>TM</sup> SM Clinical Analyzer (Cascadion). Such automated systems suit the requirements of the reference method and are designed to completely eliminate all of the manual procedures. More than 2000 immunosuppressant samples were analyzed both with the open LC-MS/MS and with Cascadion. Statistics allowed the evaluation of linearity, intra- and inter-assay CV%, bias %, limit of detection and of quantitation, and Passing–Bablok and Bland–Altman plots. Results indicated a good correlation between the two methods. In both cases, methods confirmed their suitability for diagnostic settings. Cascadion could provide support when the presence of specialized personnel is lacking, and/or when great productivity and continuous workflow are required. |
first_indexed | 2024-03-09T12:04:18Z |
format | Article |
id | doaj.art-077706c8b0414c709cbd3645393a058c |
institution | Directory Open Access Journal |
issn | 2076-3417 |
language | English |
last_indexed | 2024-03-09T12:04:18Z |
publishDate | 2022-04-01 |
publisher | MDPI AG |
record_format | Article |
series | Applied Sciences |
spelling | doaj.art-077706c8b0414c709cbd3645393a058c2023-11-30T22:59:15ZengMDPI AGApplied Sciences2076-34172022-04-01127369510.3390/app12073695Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation?Chiara Fania0Marco Bagnati1Marina Albertario2Carlotta Ferraris3Marta Lamonaca4Umberto Dianzani5Clinical Chemistry Laboratory, Maggiore della Carità University Hospital, 28100 Novara, ItalyClinical Chemistry Laboratory, Maggiore della Carità University Hospital, 28100 Novara, ItalyClinical Chemistry Laboratory, Maggiore della Carità University Hospital, 28100 Novara, ItalyClinical Chemistry Laboratory, Maggiore della Carità University Hospital, 28100 Novara, ItalyIRCAD & Department of Health Sciences, Amedeo Avogadro University of Eastern Piedmont, 28100 Novara, ItalyClinical Chemistry Laboratory, Maggiore della Carità University Hospital, 28100 Novara, ItalyThe analysis of immunosuppressive drugs allows the physician to monitor, and eventually correct, immunosuppressive therapy. The panel of molecules under evaluation includes cyclosporine A (CsA), tacrolimus, sirolimus, and everolimus. Initially, assays were performed by immunometric methods, but in the past few years this methodology has been largely superseded by a more accurate and specific technique, liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), which is now considered the “gold standard” for immunosuppressant analysis. Both LC-MS/MS and often also immunoassays require a preanalytical manual sample preparation, which involves time-consuming sequential operations whose traceability is often hampered and adds up to the probability of gross errors. The aim of this work was to compare an “open” LC-MS/MS with a fully automated system, consisting of LC instrumentation combined with a triple quadrupole MS, named Thermo Scientific<sup>TM</sup> Cascadion<sup>TM</sup> SM Clinical Analyzer (Cascadion). Such automated systems suit the requirements of the reference method and are designed to completely eliminate all of the manual procedures. More than 2000 immunosuppressant samples were analyzed both with the open LC-MS/MS and with Cascadion. Statistics allowed the evaluation of linearity, intra- and inter-assay CV%, bias %, limit of detection and of quantitation, and Passing–Bablok and Bland–Altman plots. Results indicated a good correlation between the two methods. In both cases, methods confirmed their suitability for diagnostic settings. Cascadion could provide support when the presence of specialized personnel is lacking, and/or when great productivity and continuous workflow are required.https://www.mdpi.com/2076-3417/12/7/3695LC-MS/MSTDMautomation |
spellingShingle | Chiara Fania Marco Bagnati Marina Albertario Carlotta Ferraris Marta Lamonaca Umberto Dianzani Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation? Applied Sciences LC-MS/MS TDM automation |
title | Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation? |
title_full | Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation? |
title_fullStr | Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation? |
title_full_unstemmed | Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation? |
title_short | Clinical Mass Spectrometry in Immunosuppressant Analysis: Toward a Full Automation? |
title_sort | clinical mass spectrometry in immunosuppressant analysis toward a full automation |
topic | LC-MS/MS TDM automation |
url | https://www.mdpi.com/2076-3417/12/7/3695 |
work_keys_str_mv | AT chiarafania clinicalmassspectrometryinimmunosuppressantanalysistowardafullautomation AT marcobagnati clinicalmassspectrometryinimmunosuppressantanalysistowardafullautomation AT marinaalbertario clinicalmassspectrometryinimmunosuppressantanalysistowardafullautomation AT carlottaferraris clinicalmassspectrometryinimmunosuppressantanalysistowardafullautomation AT martalamonaca clinicalmassspectrometryinimmunosuppressantanalysistowardafullautomation AT umbertodianzani clinicalmassspectrometryinimmunosuppressantanalysistowardafullautomation |