A non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirs

Abstract The determination of the formation water saturation, S w, is a continuous process throughout the life of the fields. Multiple water saturation models are developed to increase the accuracy of calculating this critical parameter for both open-hole and cased-hole wells. All current open-hole...

Full description

Bibliographic Details
Main Author: Moustafa Oraby
Format: Article
Language:English
Published: SpringerOpen 2020-07-01
Series:Journal of Petroleum Exploration and Production Technology
Subjects:
Online Access:https://doi.org/10.1007/s13202-020-00945-x
_version_ 1811181131047895040
author Moustafa Oraby
author_facet Moustafa Oraby
author_sort Moustafa Oraby
collection DOAJ
description Abstract The determination of the formation water saturation, S w, is a continuous process throughout the life of the fields. Multiple water saturation models are developed to increase the accuracy of calculating this critical parameter for both open-hole and cased-hole wells. All current open-hole water saturation models require prior knowledge of some field parameters namely; formation water resistivity, R w, clay volume, V c and rock electrical properties (m, n). It is normally assumed that those reservoir parameters as either constant for the entire reservoir section or change by zones. This is obviously an impractical assumption especially for the (m) and (n) parameters. Also, when a reservoir is under water injection for enhanced oil recovery, the water salinity may change throughout the reservoir, based on the distribution of the reservoir permeability and the salinity of the injected water, resulting in a variable R w. This case represents a real challenge to the existing water saturation models. In this paper, a methodology to determine water saturation without the need for prior knowledge of the formation water resistivity or the rock electrical properties is developed. This approach is a generalization of the Passey total organic carbon, TOC, model which is developed to determine the organic richness of the unconventional reservoirs. The scientific basis of the method, the modification required to be applied in conventional reservoirs, the proof of concept using forward modeled cases and actual field applications in sandstone and carbonate reservoirs are performed to examine the theoretical and the practical applications of the methodology. Excellent results are obtained and discussed.
first_indexed 2024-04-11T09:13:26Z
format Article
id doaj.art-07e7745968374eb8ae200108ccc15373
institution Directory Open Access Journal
issn 2190-0558
2190-0566
language English
last_indexed 2024-04-11T09:13:26Z
publishDate 2020-07-01
publisher SpringerOpen
record_format Article
series Journal of Petroleum Exploration and Production Technology
spelling doaj.art-07e7745968374eb8ae200108ccc153732022-12-22T04:32:25ZengSpringerOpenJournal of Petroleum Exploration and Production Technology2190-05582190-05662020-07-011083295330810.1007/s13202-020-00945-xA non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirsMoustafa Oraby0American University in CairoAbstract The determination of the formation water saturation, S w, is a continuous process throughout the life of the fields. Multiple water saturation models are developed to increase the accuracy of calculating this critical parameter for both open-hole and cased-hole wells. All current open-hole water saturation models require prior knowledge of some field parameters namely; formation water resistivity, R w, clay volume, V c and rock electrical properties (m, n). It is normally assumed that those reservoir parameters as either constant for the entire reservoir section or change by zones. This is obviously an impractical assumption especially for the (m) and (n) parameters. Also, when a reservoir is under water injection for enhanced oil recovery, the water salinity may change throughout the reservoir, based on the distribution of the reservoir permeability and the salinity of the injected water, resulting in a variable R w. This case represents a real challenge to the existing water saturation models. In this paper, a methodology to determine water saturation without the need for prior knowledge of the formation water resistivity or the rock electrical properties is developed. This approach is a generalization of the Passey total organic carbon, TOC, model which is developed to determine the organic richness of the unconventional reservoirs. The scientific basis of the method, the modification required to be applied in conventional reservoirs, the proof of concept using forward modeled cases and actual field applications in sandstone and carbonate reservoirs are performed to examine the theoretical and the practical applications of the methodology. Excellent results are obtained and discussed.https://doi.org/10.1007/s13202-020-00945-xWater saturationNon-archie water saturationUnconventional reservoirsPassey model
spellingShingle Moustafa Oraby
A non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirs
Journal of Petroleum Exploration and Production Technology
Water saturation
Non-archie water saturation
Unconventional reservoirs
Passey model
title A non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirs
title_full A non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirs
title_fullStr A non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirs
title_full_unstemmed A non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirs
title_short A non-Archie water saturation method for conventional reservoirs based on generalization of Passey TOC model for unconventional reservoirs
title_sort non archie water saturation method for conventional reservoirs based on generalization of passey toc model for unconventional reservoirs
topic Water saturation
Non-archie water saturation
Unconventional reservoirs
Passey model
url https://doi.org/10.1007/s13202-020-00945-x
work_keys_str_mv AT moustafaoraby anonarchiewatersaturationmethodforconventionalreservoirsbasedongeneralizationofpasseytocmodelforunconventionalreservoirs
AT moustafaoraby nonarchiewatersaturationmethodforconventionalreservoirsbasedongeneralizationofpasseytocmodelforunconventionalreservoirs