Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator

Presented are voltage measurements taken near the load region on the Z pulsed-power accelerator using an inductive voltage monitor (IVM). Specifically, the IVM was connected to, and thus monitored the voltage at, the bottom level of the accelerator’s vacuum double post-hole convolute. Additional vol...

Full description

Bibliographic Details
Main Authors: E. M. Waisman, R. D. McBride, M. E. Cuneo, D. F. Wenger, W. E. Fowler, W. A. Johnson, L. I. Basilio, R. S. Coats, C. A. Jennings, D. B. Sinars, R. A. Vesey, B. Jones, D. J. Ampleford, R. W. Lemke, M. R. Martin, P. C. Schrafel, S. A. Lewis, J. K. Moore, M. E. Savage, W. A. Stygar
Format: Article
Language:English
Published: American Physical Society 2014-12-01
Series:Physical Review Special Topics. Accelerators and Beams
Online Access:http://doi.org/10.1103/PhysRevSTAB.17.120401
_version_ 1811324226002485248
author E. M. Waisman
R. D. McBride
M. E. Cuneo
D. F. Wenger
W. E. Fowler
W. A. Johnson
L. I. Basilio
R. S. Coats
C. A. Jennings
D. B. Sinars
R. A. Vesey
B. Jones
D. J. Ampleford
R. W. Lemke
M. R. Martin
P. C. Schrafel
S. A. Lewis
J. K. Moore
M. E. Savage
W. A. Stygar
author_facet E. M. Waisman
R. D. McBride
M. E. Cuneo
D. F. Wenger
W. E. Fowler
W. A. Johnson
L. I. Basilio
R. S. Coats
C. A. Jennings
D. B. Sinars
R. A. Vesey
B. Jones
D. J. Ampleford
R. W. Lemke
M. R. Martin
P. C. Schrafel
S. A. Lewis
J. K. Moore
M. E. Savage
W. A. Stygar
author_sort E. M. Waisman
collection DOAJ
description Presented are voltage measurements taken near the load region on the Z pulsed-power accelerator using an inductive voltage monitor (IVM). Specifically, the IVM was connected to, and thus monitored the voltage at, the bottom level of the accelerator’s vacuum double post-hole convolute. Additional voltage and current measurements were taken at the accelerator’s vacuum-insulator stack (at a radius of 1.6 m) by using standard D-dot and B-dot probes, respectively. During postprocessing, the measurements taken at the stack were translated to the location of the IVM measurements by using a lossless propagation model of the Z accelerator’s magnetically insulated transmission lines (MITLs) and a lumped inductor model of the vacuum post-hole convolute. Across a wide variety of experiments conducted on the Z accelerator, the voltage histories obtained from the IVM and the lossless propagation technique agree well in overall shape and magnitude. However, large-amplitude, high-frequency oscillations are more pronounced in the IVM records. It is unclear whether these larger oscillations represent true voltage oscillations at the convolute or if they are due to noise pickup and/or transit-time effects and other resonant modes in the IVM. Results using a transit-time-correction technique and Fourier analysis support the latter. Regardless of which interpretation is correct, both true voltage oscillations and the excitement of resonant modes could be the result of transient electrical breakdowns in the post-hole convolute, though more information is required to determine definitively if such breakdowns occurred. Despite the larger oscillations in the IVM records, the general agreement found between the lossless propagation results and the results of the IVM shows that large voltages are transmitted efficiently through the MITLs on Z. These results are complementary to previous studies [R. D. McBride et al., Phys. Rev. ST Accel. Beams 13, 120401 (2010)] that showed efficient transmission of large currents through the MITLs on Z. Taken together, the two studies demonstrate the overall efficient delivery of very large electrical powers through the MITLs on Z.
first_indexed 2024-04-13T14:10:33Z
format Article
id doaj.art-0846d3d02e1040e2914332d96df96364
institution Directory Open Access Journal
issn 1098-4402
language English
last_indexed 2024-04-13T14:10:33Z
publishDate 2014-12-01
publisher American Physical Society
record_format Article
series Physical Review Special Topics. Accelerators and Beams
spelling doaj.art-0846d3d02e1040e2914332d96df963642022-12-22T02:43:48ZengAmerican Physical SocietyPhysical Review Special Topics. Accelerators and Beams1098-44022014-12-01171212040110.1103/PhysRevSTAB.17.120401Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power acceleratorE. M. WaismanR. D. McBrideM. E. CuneoD. F. WengerW. E. FowlerW. A. JohnsonL. I. BasilioR. S. CoatsC. A. JenningsD. B. SinarsR. A. VeseyB. JonesD. J. AmplefordR. W. LemkeM. R. MartinP. C. SchrafelS. A. LewisJ. K. MooreM. E. SavageW. A. StygarPresented are voltage measurements taken near the load region on the Z pulsed-power accelerator using an inductive voltage monitor (IVM). Specifically, the IVM was connected to, and thus monitored the voltage at, the bottom level of the accelerator’s vacuum double post-hole convolute. Additional voltage and current measurements were taken at the accelerator’s vacuum-insulator stack (at a radius of 1.6 m) by using standard D-dot and B-dot probes, respectively. During postprocessing, the measurements taken at the stack were translated to the location of the IVM measurements by using a lossless propagation model of the Z accelerator’s magnetically insulated transmission lines (MITLs) and a lumped inductor model of the vacuum post-hole convolute. Across a wide variety of experiments conducted on the Z accelerator, the voltage histories obtained from the IVM and the lossless propagation technique agree well in overall shape and magnitude. However, large-amplitude, high-frequency oscillations are more pronounced in the IVM records. It is unclear whether these larger oscillations represent true voltage oscillations at the convolute or if they are due to noise pickup and/or transit-time effects and other resonant modes in the IVM. Results using a transit-time-correction technique and Fourier analysis support the latter. Regardless of which interpretation is correct, both true voltage oscillations and the excitement of resonant modes could be the result of transient electrical breakdowns in the post-hole convolute, though more information is required to determine definitively if such breakdowns occurred. Despite the larger oscillations in the IVM records, the general agreement found between the lossless propagation results and the results of the IVM shows that large voltages are transmitted efficiently through the MITLs on Z. These results are complementary to previous studies [R. D. McBride et al., Phys. Rev. ST Accel. Beams 13, 120401 (2010)] that showed efficient transmission of large currents through the MITLs on Z. Taken together, the two studies demonstrate the overall efficient delivery of very large electrical powers through the MITLs on Z.http://doi.org/10.1103/PhysRevSTAB.17.120401
spellingShingle E. M. Waisman
R. D. McBride
M. E. Cuneo
D. F. Wenger
W. E. Fowler
W. A. Johnson
L. I. Basilio
R. S. Coats
C. A. Jennings
D. B. Sinars
R. A. Vesey
B. Jones
D. J. Ampleford
R. W. Lemke
M. R. Martin
P. C. Schrafel
S. A. Lewis
J. K. Moore
M. E. Savage
W. A. Stygar
Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator
Physical Review Special Topics. Accelerators and Beams
title Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator
title_full Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator
title_fullStr Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator
title_full_unstemmed Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator
title_short Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator
title_sort voltage measurements at the vacuum post hole convolute of the z pulsed power accelerator
url http://doi.org/10.1103/PhysRevSTAB.17.120401
work_keys_str_mv AT emwaisman voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT rdmcbride voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT mecuneo voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT dfwenger voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT wefowler voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT wajohnson voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT libasilio voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT rscoats voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT cajennings voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT dbsinars voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT ravesey voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT bjones voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT djampleford voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT rwlemke voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT mrmartin voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT pcschrafel voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT salewis voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT jkmoore voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT mesavage voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator
AT wastygar voltagemeasurementsatthevacuumpostholeconvoluteofthezpulsedpoweraccelerator