Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed Objects

Investigations that were conducted with the help of overhead transmission line model reflecting such situations as wire swinging cross, their contact with fallen trees and other earthed objects have shown that the overhead transmission line may operate rather long under such conditions. However leak...

Full description

Bibliographic Details
Main Authors: K. F. Stepanchuk, G. S. Klimovich, A. S. Krasko, M. S. Laman
Format: Article
Language:Russian
Published: Belarusian National Technical University 2004-04-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Online Access:https://energy.bntu.by/jour/article/view/1113
_version_ 1797879933188440064
author K. F. Stepanchuk
G. S. Klimovich
A. S. Krasko
M. S. Laman
author_facet K. F. Stepanchuk
G. S. Klimovich
A. S. Krasko
M. S. Laman
author_sort K. F. Stepanchuk
collection DOAJ
description Investigations that were conducted with the help of overhead transmission line model reflecting such situations as wire swinging cross, their contact with fallen trees and other earthed objects have shown that the overhead transmission line may operate rather long under such conditions. However leakage current may lead to dangerous high potentials on these objects and around them.The results of calculations and experimental research have revealed that in the case of dry surface of polyethylene coating of overhead transmission line wire leakage current on earthed object and insulation resistance is determined by object-wire capacitance and it does not depend on specimen length and object resistance. Leakage current does not exceed 1 mA and insulation impedance is not less than 50 Nffi for real overhead transmission line spans.
first_indexed 2024-04-10T02:56:29Z
format Article
id doaj.art-087c82bf71184719abb75a21c588bdce
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2024-04-10T02:56:29Z
publishDate 2004-04-01
publisher Belarusian National Technical University
record_format Article
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
spelling doaj.art-087c82bf71184719abb75a21c588bdce2023-03-13T07:41:42ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412004-04-0102111610.21122/1029-7448-2004-0-2-11-161073Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed ObjectsK. F. Stepanchuk0G. S. Klimovich1A. S. Krasko2M. S. Laman3Белорусский национальный технический университетБелорусский национальный технический университетБелорусский национальный технический университетБелорусский национальный технический университетInvestigations that were conducted with the help of overhead transmission line model reflecting such situations as wire swinging cross, their contact with fallen trees and other earthed objects have shown that the overhead transmission line may operate rather long under such conditions. However leakage current may lead to dangerous high potentials on these objects and around them.The results of calculations and experimental research have revealed that in the case of dry surface of polyethylene coating of overhead transmission line wire leakage current on earthed object and insulation resistance is determined by object-wire capacitance and it does not depend on specimen length and object resistance. Leakage current does not exceed 1 mA and insulation impedance is not less than 50 Nffi for real overhead transmission line spans.https://energy.bntu.by/jour/article/view/1113
spellingShingle K. F. Stepanchuk
G. S. Klimovich
A. S. Krasko
M. S. Laman
Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed Objects
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
title Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed Objects
title_full Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed Objects
title_fullStr Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed Objects
title_full_unstemmed Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed Objects
title_short Determination of Leakage Current through Dry Insulated Coating of 10 kV Overhead Transmission Line Wires in case of Their Contact with Trees and Other Earthed Objects
title_sort determination of leakage current through dry insulated coating of 10 kv overhead transmission line wires in case of their contact with trees and other earthed objects
url https://energy.bntu.by/jour/article/view/1113
work_keys_str_mv AT kfstepanchuk determinationofleakagecurrentthroughdryinsulatedcoatingof10kvoverheadtransmissionlinewiresincaseoftheircontactwithtreesandotherearthedobjects
AT gsklimovich determinationofleakagecurrentthroughdryinsulatedcoatingof10kvoverheadtransmissionlinewiresincaseoftheircontactwithtreesandotherearthedobjects
AT askrasko determinationofleakagecurrentthroughdryinsulatedcoatingof10kvoverheadtransmissionlinewiresincaseoftheircontactwithtreesandotherearthedobjects
AT mslaman determinationofleakagecurrentthroughdryinsulatedcoatingof10kvoverheadtransmissionlinewiresincaseoftheircontactwithtreesandotherearthedobjects