The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, Alberta

Data from automated meteorological instruments are used for model validation and aviation applications, but their measurement accuracy has not being adequately tested. In this study, a number of ground-based in-situ, remote-sensing instruments that measure visibility (VIS), cloud base height (CBH),...

Full description

Bibliographic Details
Main Authors: Faisal S. Boudala, Ismail Gultepe, Jason A. Milbrandt
Format: Article
Language:English
Published: MDPI AG 2021-12-01
Series:Remote Sensing
Subjects:
Online Access:https://www.mdpi.com/2072-4292/13/24/5058
_version_ 1797500949906849792
author Faisal S. Boudala
Ismail Gultepe
Jason A. Milbrandt
author_facet Faisal S. Boudala
Ismail Gultepe
Jason A. Milbrandt
author_sort Faisal S. Boudala
collection DOAJ
description Data from automated meteorological instruments are used for model validation and aviation applications, but their measurement accuracy has not being adequately tested. In this study, a number of ground-based in-situ, remote-sensing instruments that measure visibility (VIS), cloud base height (CBH), and relative humidity (RH) were tested against data obtained using standard reference instruments and human observations at Cold Lake Airport, Alberta, Canada. The instruments included the Vaisala FS11P and PWD22 (FSPW), a profiling microwave radiometer (MWR), the Jenoptik ceilometer, Rotronic, Vaisala WXT520, AES-Dewcell RH, and temperature sensors. The results showed that the VIS measured using the FSPWs were well correlated with a correlation coefficient (R) of 0.84 under precipitation conditions and 0.96 during non-precipitating conditions (NPC), indicating very good agreement. However, the FS11P on average measured higher VIS, particularly under NPC. When the FSPWs were compared against human observation, a significant quantization in the data was observed, but less was noted during daytime compared to nighttime. Both probes measured higher VIS compared to human observation, and the calculated R was close to 0.6 for both probes. When the FSPWs were compared against human observation for VIS < 4 km, the calculated mean difference (MD) for the PWD22 (MD ≈ 0.98 km) was better than the FS11P (MD ≈ 1.37 km); thus, the PWD22 was slightly closer to human observation than the FS11P. No significant difference was found between daytime and nighttime measured VIS as compared to human observation; the instruments measured slightly higher VIS. Two extinction parameterizations as functions of snowfall rate were developed based on the VFPs measurements, and the results were similar. The Jenoptik ceilometer generally measured lower CBH than human observation, but the MWR measured larger CBHs for values <2 km, while CBHs were underestimated for higher CBHs.
first_indexed 2024-03-10T03:11:14Z
format Article
id doaj.art-091983a753814664b513b6a44b6aa871
institution Directory Open Access Journal
issn 2072-4292
language English
last_indexed 2024-03-10T03:11:14Z
publishDate 2021-12-01
publisher MDPI AG
record_format Article
series Remote Sensing
spelling doaj.art-091983a753814664b513b6a44b6aa8712023-11-23T10:24:13ZengMDPI AGRemote Sensing2072-42922021-12-011324505810.3390/rs13245058The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, AlbertaFaisal S. Boudala0Ismail Gultepe1Jason A. Milbrandt2Meteorological Research Division, Environment and Climate Change Canada, Toronto, ON 66777, CanadaMeteorological Research Division, Environment and Climate Change Canada, Toronto, ON 66777, CanadaMeteorological Research Division, Environment and Climate Change Canada, Dorval, QC H9P 1J3, CanadaData from automated meteorological instruments are used for model validation and aviation applications, but their measurement accuracy has not being adequately tested. In this study, a number of ground-based in-situ, remote-sensing instruments that measure visibility (VIS), cloud base height (CBH), and relative humidity (RH) were tested against data obtained using standard reference instruments and human observations at Cold Lake Airport, Alberta, Canada. The instruments included the Vaisala FS11P and PWD22 (FSPW), a profiling microwave radiometer (MWR), the Jenoptik ceilometer, Rotronic, Vaisala WXT520, AES-Dewcell RH, and temperature sensors. The results showed that the VIS measured using the FSPWs were well correlated with a correlation coefficient (R) of 0.84 under precipitation conditions and 0.96 during non-precipitating conditions (NPC), indicating very good agreement. However, the FS11P on average measured higher VIS, particularly under NPC. When the FSPWs were compared against human observation, a significant quantization in the data was observed, but less was noted during daytime compared to nighttime. Both probes measured higher VIS compared to human observation, and the calculated R was close to 0.6 for both probes. When the FSPWs were compared against human observation for VIS < 4 km, the calculated mean difference (MD) for the PWD22 (MD ≈ 0.98 km) was better than the FS11P (MD ≈ 1.37 km); thus, the PWD22 was slightly closer to human observation than the FS11P. No significant difference was found between daytime and nighttime measured VIS as compared to human observation; the instruments measured slightly higher VIS. Two extinction parameterizations as functions of snowfall rate were developed based on the VFPs measurements, and the results were similar. The Jenoptik ceilometer generally measured lower CBH than human observation, but the MWR measured larger CBHs for values <2 km, while CBHs were underestimated for higher CBHs.https://www.mdpi.com/2072-4292/13/24/5058ceilometer and radiometric profilingvisibilitycloud base heightrelative humidity
spellingShingle Faisal S. Boudala
Ismail Gultepe
Jason A. Milbrandt
The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, Alberta
Remote Sensing
ceilometer and radiometric profiling
visibility
cloud base height
relative humidity
title The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, Alberta
title_full The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, Alberta
title_fullStr The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, Alberta
title_full_unstemmed The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, Alberta
title_short The Performance of Commonly Used Surface-Based Instruments for Measuring Visibility, Cloud Ceiling, and Humidity at Cold Lake, Alberta
title_sort performance of commonly used surface based instruments for measuring visibility cloud ceiling and humidity at cold lake alberta
topic ceilometer and radiometric profiling
visibility
cloud base height
relative humidity
url https://www.mdpi.com/2072-4292/13/24/5058
work_keys_str_mv AT faisalsboudala theperformanceofcommonlyusedsurfacebasedinstrumentsformeasuringvisibilitycloudceilingandhumidityatcoldlakealberta
AT ismailgultepe theperformanceofcommonlyusedsurfacebasedinstrumentsformeasuringvisibilitycloudceilingandhumidityatcoldlakealberta
AT jasonamilbrandt theperformanceofcommonlyusedsurfacebasedinstrumentsformeasuringvisibilitycloudceilingandhumidityatcoldlakealberta
AT faisalsboudala performanceofcommonlyusedsurfacebasedinstrumentsformeasuringvisibilitycloudceilingandhumidityatcoldlakealberta
AT ismailgultepe performanceofcommonlyusedsurfacebasedinstrumentsformeasuringvisibilitycloudceilingandhumidityatcoldlakealberta
AT jasonamilbrandt performanceofcommonlyusedsurfacebasedinstrumentsformeasuringvisibilitycloudceilingandhumidityatcoldlakealberta