The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments

The goal of the study is to evaluate if the use of rotary nickel-titanium (RNT) instruments, as Hedstroem files, is safe. Twelve twisted files (TF) RNT instruments size 06-25 were selected and randomly divided in 2 groups of 6 instruments each. Group A (new instruments) were used as control. Group B...

Full description

Bibliographic Details
Main Authors: Gianluca Gambarini, Eugenio Tucci, Rossella Bedini, Raffaella Pecci, Massimo Galli, Valerio Milana, Massimo De Luca, Luca Testarelli
Format: Article
Language:English
Published: Istituto Superiore di Sanità 2010-12-01
Series:Annali dell'Istituto Superiore di Sanità
Subjects:
Online Access:http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712010000400007&lng=en&tlng=en
_version_ 1828822709209923584
author Gianluca Gambarini
Eugenio Tucci
Rossella Bedini
Raffaella Pecci
Massimo Galli
Valerio Milana
Massimo De Luca
Luca Testarelli
author_facet Gianluca Gambarini
Eugenio Tucci
Rossella Bedini
Raffaella Pecci
Massimo Galli
Valerio Milana
Massimo De Luca
Luca Testarelli
author_sort Gianluca Gambarini
collection DOAJ
description The goal of the study is to evaluate if the use of rotary nickel-titanium (RNT) instruments, as Hedstroem files, is safe. Twelve twisted files (TF) RNT instruments size 06-25 were selected and randomly divided in 2 groups of 6 instruments each. Group A (new instruments) were used as control. Group B (test) instruments were clinically used only as Hedstroem files in a canal that had been previously instrumented to the working length with other 06-25 RNT instruments. Group B instruments were used only in the straight portion of the canal (1 minute at 1000 rpm). A cyclic fatigue test was performed for each instrument of groups. Data were statistically analyzed (Student's t-test). Results showed no significant difference (P > 0.05) between groups A and B. Data confirmed that the use of TF instruments as Hedstroem files is a safe procedure. Cross section images and volumes of the same instrument, before and after cyclic fatigue testing, have been obtained by means of microtomographic analysis to evaluate possible microstructure alterations.
first_indexed 2024-12-12T13:18:56Z
format Article
id doaj.art-09644b6b818141a3b4372b2cb2a2c0aa
institution Directory Open Access Journal
issn 0021-2571
language English
last_indexed 2024-12-12T13:18:56Z
publishDate 2010-12-01
publisher Istituto Superiore di Sanità
record_format Article
series Annali dell'Istituto Superiore di Sanità
spelling doaj.art-09644b6b818141a3b4372b2cb2a2c0aa2022-12-22T00:23:20ZengIstituto Superiore di SanitàAnnali dell'Istituto Superiore di Sanità0021-25712010-12-0146440040410.4415/ANN_10_04_07S0021-25712010000400007The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instrumentsGianluca Gambarini0Eugenio Tucci1Rossella Bedini2Raffaella Pecci3Massimo Galli4Valerio Milana5Massimo De Luca6Luca Testarelli7Sapienza Università di RomaSapienza Università di RomaIstituto Superiore di SanitàIstituto Superiore di SanitàSapienza Università di RomaSapienza Università di RomaSapienza Università di RomaSapienza Università di RomaThe goal of the study is to evaluate if the use of rotary nickel-titanium (RNT) instruments, as Hedstroem files, is safe. Twelve twisted files (TF) RNT instruments size 06-25 were selected and randomly divided in 2 groups of 6 instruments each. Group A (new instruments) were used as control. Group B (test) instruments were clinically used only as Hedstroem files in a canal that had been previously instrumented to the working length with other 06-25 RNT instruments. Group B instruments were used only in the straight portion of the canal (1 minute at 1000 rpm). A cyclic fatigue test was performed for each instrument of groups. Data were statistically analyzed (Student's t-test). Results showed no significant difference (P > 0.05) between groups A and B. Data confirmed that the use of TF instruments as Hedstroem files is a safe procedure. Cross section images and volumes of the same instrument, before and after cyclic fatigue testing, have been obtained by means of microtomographic analysis to evaluate possible microstructure alterations.http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712010000400007&lng=en&tlng=enstrumenti endodonticinicheltitaniofatica ciclica
spellingShingle Gianluca Gambarini
Eugenio Tucci
Rossella Bedini
Raffaella Pecci
Massimo Galli
Valerio Milana
Massimo De Luca
Luca Testarelli
The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments
Annali dell'Istituto Superiore di Sanità
strumenti endodontici
nichel
titanio
fatica ciclica
title The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments
title_full The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments
title_fullStr The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments
title_full_unstemmed The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments
title_short The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments
title_sort effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments
topic strumenti endodontici
nichel
titanio
fatica ciclica
url http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712010000400007&lng=en&tlng=en
work_keys_str_mv AT gianlucagambarini theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT eugeniotucci theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT rossellabedini theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT raffaellapecci theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT massimogalli theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT valeriomilana theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT massimodeluca theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT lucatestarelli theeffectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT gianlucagambarini effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT eugeniotucci effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT rossellabedini effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT raffaellapecci effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT massimogalli effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT valeriomilana effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT massimodeluca effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments
AT lucatestarelli effectofbrushingmotiononthecyclicfatigueofrotarynickeltitaniuminstruments