Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm
Subsynchronous oscillation (SSO) is a critical issue for the direct-drive permanent magnet synchronous generator (D-PMSG) based wind farm integrated to a weak onshore AC grid. To analyze the mechanism of the SSO phenomenon of D-PMSG based wind farm, widely used impedance-based stability analysis met...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-07-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/9/14/2831 |
_version_ | 1828879294903877632 |
---|---|
author | Saijun Yuan Zhiguo Hao Tao Zhang Xiaotian Yuan Jin Shu |
author_facet | Saijun Yuan Zhiguo Hao Tao Zhang Xiaotian Yuan Jin Shu |
author_sort | Saijun Yuan |
collection | DOAJ |
description | Subsynchronous oscillation (SSO) is a critical issue for the direct-drive permanent magnet synchronous generator (D-PMSG) based wind farm integrated to a weak onshore AC grid. To analyze the mechanism of the SSO phenomenon of D-PMSG based wind farm, widely used impedance-based stability analysis method is utilized in this paper. First, the impedance model based on the harmonic linearization theory of grid-connected D-PMSG is proposed, and the mechanism of sub/supsynchronous currents coupling is analyzed quantitatively for the first time. Then, based on the impedance model and relative stability criterion, the influence of wind farm operating parameters and grid impedance on stability is discussed. Simulations are carried out to verify the correctness of theoretical analysis. |
first_indexed | 2024-12-13T09:25:31Z |
format | Article |
id | doaj.art-09f99ea206c04d5a8a03595eb1537d28 |
institution | Directory Open Access Journal |
issn | 2076-3417 |
language | English |
last_indexed | 2024-12-13T09:25:31Z |
publishDate | 2019-07-01 |
publisher | MDPI AG |
record_format | Article |
series | Applied Sciences |
spelling | doaj.art-09f99ea206c04d5a8a03595eb1537d282022-12-21T23:52:38ZengMDPI AGApplied Sciences2076-34172019-07-01914283110.3390/app9142831app9142831Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind FarmSaijun Yuan0Zhiguo Hao1Tao Zhang2Xiaotian Yuan3Jin Shu4School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, Shaanxi, ChinaSchool of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, Shaanxi, ChinaSchool of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, Shaanxi, ChinaSchool of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, Shaanxi, ChinaXi’an Thermal Power Research Institute Co., Ltd., Xi’an 710054, Shaanxi, ChinaSubsynchronous oscillation (SSO) is a critical issue for the direct-drive permanent magnet synchronous generator (D-PMSG) based wind farm integrated to a weak onshore AC grid. To analyze the mechanism of the SSO phenomenon of D-PMSG based wind farm, widely used impedance-based stability analysis method is utilized in this paper. First, the impedance model based on the harmonic linearization theory of grid-connected D-PMSG is proposed, and the mechanism of sub/supsynchronous currents coupling is analyzed quantitatively for the first time. Then, based on the impedance model and relative stability criterion, the influence of wind farm operating parameters and grid impedance on stability is discussed. Simulations are carried out to verify the correctness of theoretical analysis.https://www.mdpi.com/2076-3417/9/14/2831direct-drive permanent magnet synchronous generator (D-PMSG)frequency couplingharmonic linearizationimpedance modelingsub/supsynchronous oscillation |
spellingShingle | Saijun Yuan Zhiguo Hao Tao Zhang Xiaotian Yuan Jin Shu Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm Applied Sciences direct-drive permanent magnet synchronous generator (D-PMSG) frequency coupling harmonic linearization impedance modeling sub/supsynchronous oscillation |
title | Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm |
title_full | Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm |
title_fullStr | Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm |
title_full_unstemmed | Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm |
title_short | Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm |
title_sort | impedance modeling based method for sub supsynchronous oscillation analysis of d pmsg wind farm |
topic | direct-drive permanent magnet synchronous generator (D-PMSG) frequency coupling harmonic linearization impedance modeling sub/supsynchronous oscillation |
url | https://www.mdpi.com/2076-3417/9/14/2831 |
work_keys_str_mv | AT saijunyuan impedancemodelingbasedmethodforsubsupsynchronousoscillationanalysisofdpmsgwindfarm AT zhiguohao impedancemodelingbasedmethodforsubsupsynchronousoscillationanalysisofdpmsgwindfarm AT taozhang impedancemodelingbasedmethodforsubsupsynchronousoscillationanalysisofdpmsgwindfarm AT xiaotianyuan impedancemodelingbasedmethodforsubsupsynchronousoscillationanalysisofdpmsgwindfarm AT jinshu impedancemodelingbasedmethodforsubsupsynchronousoscillationanalysisofdpmsgwindfarm |